1. Initialize parameters
Before wiring, initialize the parameters.
On the control card: select the control mode; Reset the PID parameter to zero; When the control card is powered on, the enabling signal is turned off by default; Save this state to make sure that this is the status when the adapter is powered on again.
On the servo motor: set the control mode; Setup enable is externally controlled; the gear ratio of the encoder signal output; Set the proportional relationship between the control signal and the speed of the motor. In general, it is recommended that the maximum design speed of the servo operation correspond to the control voltage of 9V. For example, if Sanyo sets the speed corresponding to 1V voltage, and the factory value is 500, if you only want the motor to work below 1000 rpm, then set this parameter to 111.
2. Wiring
Power off the control card and connect the signal line between the control card and the servo. The following cables must be connected: the analog output line of the control card, the enable signal line, and the encoder signal line of the servo output. After checking that there are no errors in the wiring, the motor and control card (and PC) are powered on. At this point, the motor should not move and can be easily rotated with external force, if not, check the settings and wiring of the enable signal. Rotate the motor with external force, check whether the control card can correctly detect the change in the position of the motor, otherwise check the wiring and setting of the encoder signal
3. Test the direction
For a closed-loop control system, if the feedback signal is not oriented correctly, the consequences are certainly catastrophic. Turn on the servo's enable signal via the control card. At this time, the servo should rotate at a lower speed, which is the legendary "zero drift". Generally, there will be instructions or parameters on the control card to suppress zero drift. Use this command or parameter to see if the speed and direction of the motor can be controlled by this command (parameter). If it cannot be controlled, check the parameter settings of the analog wiring and control mode. Confirm that a positive number is given, the motor is rotated forward, and the encoder count increases; A negative number is given, the motor is reversed, and the encoder count decreases. If the motor is loaded and has a limited stroke, do not use it this way. Do not give excessive voltage for the test, it is recommended to be below 1V. If the orientation is inconsistent, the parameters on the control card or motor can be modified to make them consistent.
4. Inhibit zero drift
In the process of closed-loop control, the existence of zero drift will have a certain impact on the control effect, and it is best to suppress it. Use the parameters on the control card or servo to suppress zero drift and carefully adjust the speed of the motor to close to zero. Since zero drift itself also has a certain randomness, it is not necessary to require the motor speed to be absolutely zero.
5. Establish closed-loop control
Again through the control card to release the servo enable signal, on the control card input a small proportion of gain, as for how small is small, this can only be felt, if you are really not at ease, enter the minimum value that the control card can allow. Turn on the enable signals of the control card and servo. At this point, the motor should be able to roughly act according to the motion commands.
6. Adjust closed-loop parameters
Fine-tune the control parameters to ensure that the motor moves according to the instructions of the control card, which is a work that must be done, and this part of the work, more experience, can only be omitted here.
|
More on that
|
Eston servo features
Features of Estun servo.
High overload capacity.
The capacity of the industrial-grade intelligent power module IPM selected by the EDB/EDC servo drive is larger than that of similar servo products that are usually calibrated with the same power, and has the characteristics of strong overload capacity, strong anti-load disturbance ability, and large starting torque.
|
|
Estun servo motor - the category, structure and performance of "precision transmission micro motor".
AC servo motor
(1) Cage type two-phase AC servo motor (slender cage rotor, mechanical characteristics are approximately linear, small volume and excitation current, small power servo, low-speed operation is not smooth enough)
(2) Non-magnetic cup rotor two-phase AC servo motor (coreless rotor, mechanical ...
|
|
Estun Servo Motor - How to Select Servo Motor (16-20)
16. Is it safe to use a DC power supply voltage greater than the rated voltage value to drive the motor?
Normally this is not a problem, as long as the motor is operating within the set speed and current limits. Because the motor speed is proportional to the motor line voltage, choosing a certain supply voltage will not cause ...
|
|
Estun Automation won the 2019 Golden Globe Award for High-tech Robots
On December 11, the 2019 Golden Globe Award Annual Conference of the Industrial Robot Industry Event "Ecological Interconnection • Breaking Through Against the Trend" was held in Shenzhen.
Zhu Chunhua of Estun Automation was invited to publish "How China's Intelligent Manufacturing Enters the Global ...
|
|
Estun Automation Ranked on the "2020 List of China's Most Innovative Enterprises"
On June 22, 2020, Forbes China released the "2020 China's Most Innovative Enterprises List", which covers 50 innovative companies in 12 fields.
With the technological innovation of a new generation of industrial robots, Estun Automation ...
|
|
Estun Medical and Burt Robot participated in the China International Medical Equipment Fair
The 2021 China International Medical Equipment Fair will be held from May 13 to 16 at the National Convention and Exhibition Center in Shanghai.
Estun Medical will exhibit the unilateral and bilateral versions of the Burt Upper Limb Rehabilitation Training System, which is more suitable for the full-cycle rehabilitation training program of the rehabilitation population, and includes adaptation ...
|
|
Estun servo motor - introduction to the control mode of AC servo motor
1. Amplitude and phase control mode
The amplitude and phase are controlled, and the speed of the servo motor is controlled by changing the amplitude of the control voltage and the phase difference between the control voltage and the excitation voltage. That is, the amplitude and phase of the control voltage UC are changed at the same time.
2. Phase control mode
Phase-controlled ...
|
|
Nanjing Eston won the "Vico Cup · OFweek 2021 China Robot Industry Annual Influential Brand Enterprise Award"
The Veken Cup is jointly organized by OFweek, a portal of China's high-tech industry, and OFweek, an authoritative robot professional media · robots· The final results of the OFweek 2021 China Robot Awards 2021 were presented on May 17.
|
|
Estun Servo Motor - How to Select Servo Motor (6-10)
6. What should I pay attention to when using the motor?
Check the following before powering on:
1) Whether the power supply voltage is appropriate (overvoltage is likely to cause damage to the drive module); The +/- polarity of the DC input must not be misconnected, and the motor model or current setting on the drive controller ...
|
|
The reason why the Estun welding robot teach pendant cannot enter the management interface
Fault 1: Contact deviation
Phenomenon 1: The direction of the finger does not coincide with the mouse arrow.
Reason 1: After the driver is installed in the teach pendant, there is no vertical contact with the bullseye when correcting the bearing.
Treatment 1: Correct the orientation from the beginning.
...
|
|
Estun Robot Teach Pendant Alarm E-STop; ERR, how to deal with it?
Generally, it means that the machine encounters an error or emergency shutdown and needs to be overhauled and maintained. Here's how to solve it:
1. Check if the power supply of the teach pendant is normal, if there is a power supply problem, it may cause the machine to stop in an emergency.
2. Check if there is an object inside the machine ...
|
|
Estun servo motor - the place where the daily maintenance of servo motor needs attention
Precautions for servo motors:
1. Protection of servo motor oil and water
A: The servo motor can be used in places where it will be attacked by water or oil droplets, but it is not fully waterproof or oil-proof. Therefore, servo motors should not be placed or used in water or oil-infested environments.
...
|
|
The Estun robot does not turn on the power after turning on the main switch of the control cabinet
1. Check whether the power supply line of the electric control cabinet is connected correctly;
2. Detect whether the external power supply voltage meets the requirements: three-phase AC380V power supply robot models: power supply robot models: ER4-1450, ER6-1600, ER10-1600, ER16-1600, ER20-1780, ER20/10-2000, ...
|
|
Estun servo motor - what are the control methods of servo motor?
1. Torque control: The torque control mode is to set the size of the output torque of the motor shaft through the input of the external analog quantity or the assignment of the direct address, which is specifically manifested as if 10V corresponds to 5Nm, when the external analog quantity is set to 5V, the output of the motor shaft is 2.5Nm: if the motor shaft ...
|
|
Estun Robot - Common faults and treatment methods of welding robots
Common system failures during the welding process
1. Collision of guns: It may be due to the error of workpiece assembly or the inaccuracy of the TCP of the welding gun, you can check the assembly situation or correct the TCP of the welding gun.
2. Arc fault, unable to start the arc: it may be due to the fact that the welding wire does not contact the workpiece or ...
|
|
The reason for the servo drive alarm A04 and its handling method
Alarm code A04 refers to:
Alarm mechanism: The overload rate of the drive accumulates to a certain threshold and triggers an alarm.
Causes:
1. Servo motor brake control circuit problem;
2. Robot power cable problem;
3. The drive parameter setting is wrong;
...
|
|
Estun servo motor fault repair method
1. Overload alarm A04
1. The wiring of the servo motor is wrong or the wiring is leaking
(1) The U, V, and W phase wires of the motor are connected incorrectly
(2) Whether the insertion of the connector on the servo motor side is defective
2. The type of servo drive and motor does not match
View drive type ...
|
|
Estun robot has A51, A47, A45, A46 fault codes
A51: The robot spindle servo motor is abnormal. It could be a cable failure, a servo drive problem, a damaged spindle bearing, etc.
A47: The servo motor is overheating. It may be because the external ambient temperature is too high, the servo motor is starting to break, and it cannot be cooled properly.
A4 ...
|
|
Estun servo motor - analysis and troubleshooting of AC servo motor fault
1. The motor cannot rotate after being energized, but there is no abnormal noise, no peculiar smell and smoke.
1. Cause of failure: (1) The power supply is not connected (at least two phases are not connected); (2) Fuse blowing (at least two-phase blowing); (3) The overcurrent relay is adjusted too small; (4) The wiring of the control equipment is incorrect.
2. Failure ...
|
|
Estun Robot - What should be paid attention to in the use of welding robots?
What points do you need to pay attention to when using welding robots?
1. It is necessary to teach the robot before active welding, and it is necessary for the operator to teach the track of the robot welding gun and set the welding conditions. Because it is necessary to teach, the robot is not oriented to many classes ...
|
|