The wearing parts of the driver mainly include electrolytic capacitors for filtering and cooling fans, and their service life is closely related to the environment and maintenance of the operation.

Depending on the operating moment, the user can determine whether a wear part needs to be replaced.

                               Senlan SV1000 servo drive wearing parts replacement

Cooling fan

Perhaps the cause of damage: bearing wear, blade aging (the life of the fan is generally 3-40,000 hours).

Criteria for identification: whether there are cracks in the blades of the electric fan, and whether there is abnormal oscillation sound when the sound is turned on.

Substitution Note:

1. When replacing, it is necessary to use the type of electric fan specified by the manufacturer (the rated voltage, current, speed, and air volume must be the same);

2. When installing, it is necessary to pay attention to the direction of the fan symbol to be consistent with the direction of the fan air supply;

3. Don't forget to put on the protective cover.

Filtered electrolytic capacitors

Possible causes of damage: high ambient temperature, increased pulsating current due to frequent load jumps, and aging of the electrolyte.

Criteria: whether there is liquid leakage, whether the safety valve has protruded, the measurement of electrostatic capacitance, and the measurement of insulation resistance.

It is advocated to replace the bus electrolytic capacitor every 4-5 years.
More on that
The reason why the frequency of the inverter cannot be adjusted - Senlan inverter The reason why the frequency of the inverter cannot be adjusted - Senlan inverter

If there is no damage to the hardware, the maximum torque output of the inverter is generally less than the load to increase the torque. The acceleration time is too short ...

The method of heat dissipation of small-capacity inverter - Sunland inverter The method of heat dissipation of small-capacity inverter - Sunland inverter

Natural heat dissipation methods are generally used for heat dissipation of small-capacity inverters, because their operating environment should be well ventilated and free of dust and floating objects. The drag targets of such inverters are mostly household air conditioners, CNC machine tools, etc., and the power is small. Still...

Heat dissipation method of small-capacity inverter - Senlan Heat dissipation method of small-capacity inverter - Senlan

Natural heat dissipation methods are generally used for heat dissipation of small-capacity inverters, because their operating environment should be well ventilated and free of dust and floating objects. The dragging objects of this type of inverter are mostly household air conditioners, CNC machine tools, etc., and the power is small. ​ ...

Energy-saving operation method of air compressor inverter - Senland Energy-saving operation method of air compressor inverter - Senland

At present, the domestic air compressor market takes the goal of energy saving, environmental protection and cost reduction as the primary demand, and the new products developed are very popular. However, economically speaking, it cannot completely replace the conventional screw air compressor with large area and large capacity in use. Therefore, the use of inverter technology to ...

The difference between inverter and inverter power supply - Senlan inverter The difference between inverter and inverter power supply - Senlan inverter

What is an inverter power supply? A variable frequency power supply converts the alternating current from the main power supply from AC→DC→AC to a pure sine wave. The output frequency and voltage can be adjusted within a specific range. Unlike the inverter governor used for the speed control of electric motors, it is also different from the general AC power supply. Aspiring AC ...

Inverter water inlet maintenance method - Sunland inverter Inverter water inlet maintenance method - Sunland inverter

The first step is not to turn on electricity! First open the inverter panel, wipe the inverter dry, and then use a hair dryer to dry the display, PC board, push board, power components, fans, etc., with 95% alcohol, scrub the components with 95% alcohol, and dry the hair dryer with cold air. Step 2: After an hour, use alcohol ...

Inverter overcurrent protection solution - Senlan Inverter overcurrent protection solution - Senlan

1. Causes of overcurrent There are many reasons for the occurrence of overcurrent, including soft and hard problems. 1. Causes of soft failures When the acceleration or deceleration time in the inverter parameters is set too short, and the motor power is heavy, it means that in the acceleration, the inverter's ...

Inverter device inspection and maintenance work steps Inverter device inspection and maintenance work steps

1. Preparation process: Abort the device and admit that the motor is completely aborted. Press the stop button on the operator panel to stop the operation. Disconnect the external mains power supply (low-voltage cabinet drawer). Adequate security treatment should be carried out to ensure that it is indeed disconnected and that it does not ...

The reason for the low output voltage of the inverter - Senlan inverter The reason for the low output voltage of the inverter - Senlan inverter

1. The power supply voltage is low The solution is to preset the active voltage adjustment function of the inverter, so that when the frequency is low and the rated frequency is dry, the inverter has the function of active voltage stabilization, and if the output voltage is low, the inverter will actively increase the output voltage ...

Wiring specification of inverter control cabinet - Senland Wiring specification of inverter control cabinet - Senland

The signal line and the power line must be routed separately: when using the analog signal to remotely control the inverter, the signal line of the control inverter and the strong current circuit (main circuit and sequential control circuit) can be separated from the inverter and other equipment to the analog interference, and the interval should be more than 30cm. Signal ...

What is the energy feedback of the inverter - Senlan inverter What is the energy feedback of the inverter - Senlan inverter

The essence of energy feedback is active inverter, and the realization method of energy feedback of general inverter is to feed renewable energy to the grid with an anti-parallel three-phase inverter at the uncontrolled rectification of the pre-stage of the general inverter. The main circuit of the energy feedback equipment is mainly composed of thyristors, IGBTs and IPM modules.

Inverter rectifier unit static detection mode Inverter rectifier unit static detection mode

The method of judging the damage of a power element in the rectifier part is to manipulate the single conductivity of the rectifier element, and the positive and negative resistance values should not be consistent when the static value is general, and the specific method is as follows: The three-phase bridge rectifier of the rectifier part may be two...

Inverter control method for motor - Senlan Inverter control method for motor - Senlan

1. U/f stable control U/f control is to change the voltage of the motor power supply together with changing the frequency of the motor power supply, so that the magnetic flux of the motor is kept constant, and the efficiency and power factor of the motor do not decrease within a wide range of speed regulation. Because it is to control the voltage and frequency ...

Sunland inverter breakdown factor Sunland inverter breakdown factor

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the fact that the inverter voltage composed of various reasons exceeds the rated voltage, which is reflected in the DC voltage of the inverter DC bus. The overvoltage alarm generally appears at the time of shutdown, and its main ...

Inverter dustproof method - Sunland inverter Inverter dustproof method - Sunland inverter

1. Plan a special inverter room When the power of the inverter is large or the number is large, a special inverter room can be planned. The doors, windows and cable holes in the room need to be sealed to avoid dust ingress; It is necessary to plan air filtration equipment and circulation channels to adhere to the normal indoor air ...

Inverter-related knowledge - Senlan inverter Inverter-related knowledge - Senlan inverter

1. What does open-loop mean in the use of inverters? The speed detector (PG) is installed on the motor equipment in operation, and the speed response of the actual speed is sent to the control equipment, which is called "closed loop", and the speed detector that does not use PG is called "open loop". Most general-purpose drives are open-loop ...

Repair and maintenance of Sunland inverter Repair and maintenance of Sunland inverter

The input and output currents of the inverter contain many higher harmonic components. In addition to the lower harmonics that can constitute the reactive power loss of the power supply, there are many harmonic components with high frequencies. They will transmit their own energy in various ways, forming a positive impact on the inverter itself and other equipment.

15 Inverter Definitions – Hope Sunland 15 Inverter Definitions – Hope Sunland

1. What is frequency conversion resolution? What's the point? In the case of digitally operated inverters, the output frequency is given in a given order, even if the frequency command is an analog signal. The smallest unit of this gradient is called the variable resolution. Change...

The eight forbidden areas of inverter control loop wiring - Senlan The eight forbidden areas of inverter control loop wiring - Senlan

1. The wires of the inverter control circuit should be strictly distinguished from the main circuit cable (power line) and placed separately. This will help prevent the inverter's control circuit from being disturbed by harmonics in the inverter's main circuit. 2. To separate the connection of the inverter from the terminals or contacts of other control circuits, ...

Motor inspection and maintenance, motor problems - Senlan Motor inspection and maintenance, motor problems - Senlan

1: In the operation of the motor, if dust, water stains and other debris enter its interior, it will constitute a short-circuit medium, which can damage the wire insulation layer, form an inter-turn short circuit, increase the current, increase the temperature and incinerate the motor. Therefore, dust, water stains and other debris should be prevented from entering the motor.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top