Mitsubishi inverter has many setting parameters, each parameter has a certain selection range, and the use of individual parameters is often improper, resulting in the inverter can not operate normally. Let's take a look at the Mitsubishi inverter parameter setting operation.
1. Mitsubishi inverter operation supervision and selection
1. Standby is now frequency supervised
2. Press the SET button to enter the current supervision
3. Press the SET button in state 2 to enter the voltage supervision
4. Press the SET button in state 3 to enter the alarm supervision
5. Press the SET button in state 4 to enter the frequency supervision
Second, the selection of Mitsubishi inverter operation form
1. Manifest the form of supervision in standby mode
2. Press the MODE button to enter the frequency setting form
3. Press the MODE key in state 2 to enter the parameter form
4. Press the MODE button in state 3 to enter the working mode
5. Press the MODE button in state 4 to enter the help form
6. Press the MODE button in state 5 to return to supervised mode
3. Introduction to the main parameters of Mitsubishi inverter
1. Capped Frequency (Pr. 1)
Limit the upper limit of the output frequency of the inverter, and set it to 120Hz at the factory
2. Lower Limit Frequency (Pr. 2)
Limit the lower limit of the output frequency of the inverter, as long as the starting signal is ON and the frequency reaches the lower limit, the motor will be started
3. Acceleration and deceleration time setting
Pr。 7. Speed up the moment Pr. 8. Deceleration moment Pr. 44 Second Acceleration Moment Pr. 45 second deceleration moment
4. Electronic Overcurrent Maintenance (Pr. 9) The factory setting value is the rated current of the inverter
5. Applicable load selection (Pr. 14)
The constant torque load (conveyor, trolley, etc.) is set to 0
The low torque load (fan, pump, etc.) is set to 1. The factory setting value is 1
6. Parameter Writing Stop Picking (Pr. 77) Set to 1 when working to avoid misoperation
Only if the abort write setting is 0. Factory set to 0
No, the write setting value is 1
Even if you work, you can write a set value of 2
7. When operating with a voltage input signal (Pr. 73)
When using voltage input to operate a signal, set the frequency of the 2-5 button of the terminal to set the standard of the voltage signal.
1) When DC is 0-5V, the setting value is Pr. 73=1 (factory setpoint)
2) When DC is 0-10V, set Pr. 73=0
When the operation signal is input with a current, the input signal between terminals 4 and 5 is shorted, and the terminals AU-SD are shorted
8. Frequency setting: Setting voltage (current) gain
Frequency-set voltage gain (Pr. 903) 60Hz at 5V (or 10V) DCs
Frequency Setting Current Gain (Pr. 905) 0Hz at DC4ma, 60Hz at DC20ma
9. Swing to avoid picking (Pr. 78)
It is used for machinery that only works in one direction, e.g. fans, pumps
The positive rotation can be set to 0, and the factory setting value is 0
The no-turn setting is 1
The rotatable setting is 2
Fourth, Mitsubishi inverter. Frequency settings
1. Select the frequency setting form first
2. Press the up and down arrow keys to add to decrease the setting frequency
3. Press the SET key to write the set frequency. The screen flashes ice to render the letter F, and the setting is successful
|
More on that
|
Explanation of Mitsubishi pIc source type and drain type
The source type is the power supply of the device, which has an input drive source and an output point with a power supply; Drain type means that the device does not have its own power supply, and the drive of the input point requires an external power supply, and the output is only a passive contact signal.
The general input points are ...
|
|
Mitsubishi PLC's communication inspection method
When you are ready to communicate through AJ71QE71, perform a ping in MS-DOS format to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. The support communicates with the Weilun touch screen through the serial port.
...
|
|
Mitsubishi Electric begins research and development of a Mars satellite probe probe
TOKYO, February 21, 2020 – Mitsubishi Electric Corporation (TOKYO:6503) announced today that it has been appointed by the Japan Aeronautics and Astronautics Agency (JAXA) as the contractor for the Mars Lunar Probe (MMX) space probe. Mitsubishi Electric has launched development activities for the project that will utilize MMX's system ...
|
|
The choice of industrial tablet case – Mitsubishi
Tablet PC can often be seen in today's daily life, it can be brought stronger, but also more popular with us, industrial tablet PC is gradually widespread, because industrial use will cause Tablet PC is very simple damage, so generally will use maintenance covers, so ...
|
|
The protection function of the inverter to the motor - Mitsubishi
The inverter is the control equipment for the operation of the motor, and it has a certain maintenance function for the motor. Most of the inverter appliances have functions such as overvoltage, overcurrent, undervoltage and overload maintenance.
Overcurrent maintenance function. In any link of motor acceleration, deceleration and constant speed operation, ...
|
|
Mitsubishi FX2N Series Extended PLC Module Selection Chart
|
|
Mitsubishi A800 series inverter realizes motor self-learning
Set it up as follows:
Press PU/EXT to switch to PU format
Pr.9 = additional current of the motor
Pr.71=3 (ordinary motor) or 13 (constant torque motor)
Pr.80 = motor power
Pr.81 = number of poles of the motor ( ...
|
|
Mitsubishi inverter FR-A800 operating environment
Comfortable operating environment for Mitsubishi inverter FR-A800
|
|
Confirmation and clearing of Mitsubishi inverter alarm history
When the FR-CS80 inverter detects an abnormality, it will display an error message or alarm in the operation panel according to the abnormal content, or maintain the function action and block the output of the inverter. When maintaining a function operation, please deal with the cause of its operation before resetting the inverter, and then start working. ...
|
|
Mitsubishi Electric develops satellites for greenhouse gas and water cycle observations
TOKYO, March 30, 2020 – Mitsubishi Electric Corporation (Tokyo: 6503) announced today that it has been appointed by the Japan Aerospace Agency (JAXA) as the contractor for the Global Satellite Observing Satellite for the Greenhouse Gas and Water Cycle (GOSAT-GW), the third satellite in the GOSAT series, ...
|
|
The role of PLC power module - Mitsubishi
Internal memory programs, logic operations, sequential manipulation, punctuality, counting, arithmetic operations, and other programmable memories are used to manipulate a variety of machinery or production processes with digital or analog inputs/outputs. PLC-related peripherals should be easy to operate with industry to form a whole, easy to expand...
|
|
Mitsubishi servo about the selection of robot methods
When evaluating which process is suitable for which approach in the production environment, it is important to carefully consider the problem you want to deal with and consider all the costs that the robot can save: cutting waste, improving efficiency, improving yield, improving safety, or reducing labor costs. These costs ...
|
|
Mitsubishi inverter pre-use debugging steps
1. No-load energizing test of Mitsubishi inverter.
1. Ground the ground terminal of the Mitsubishi inverter.
2 Connect the power input terminal of the Mitsubishi inverter to the power supply through the leakage maintenance switch.
3 Check whether the factory display window of Mitsubishi inverter is normal, if it is not correct.
|
|
What is the difference between the Mitsubishi PLC FX3U and FX5U
1. The speed of the system bus is different. Although the FX5U series is small but precise, compared with the previous product FX3U, the system bus speed is greatly increased by 150 times, and the maximum expansion module can be expanded by 16 intelligent expansion modules, built-in 2-in and 1-out analog functions, built-in Ethernet interface and 4-axis 200kHz high-speed positioning function.
...
|
|
Mitsubishi PLC control inverter method
1. Mitsubishi PLC's analog signal control inverter
Hardware: FX1N, FX2N PLC hosts, equipped with 1 simple FX1N-1DA-BD extended analog output board; or analog input-output hybrid module FX0N-3A; or FX2N-2DA with two outputs; or four outputs ...
|
|
Precautions for the use of Mitsubishi L series PLC terminal cover
Mitsubishi L series PLC is the same as Q series PLC is a modular PLC, in the specific engineering application, users according to the actual needs of the CPU, power supply, input and output and other special function modules for combination. However, there is a difference between the L series PLC and the Q series PLC in terms of hardware composition.
|
|
Introduction to the principle of Mitsubishi tension controller
The tension controller can be called the tension manipulator, which is generally equipped with magnetic powder brake, magnetic particle clutch and tension detector, and is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the ability to give a certain amount of output through the tension manipulator ...
|
|
Mitsubishi servo maintenance failure analysis
Major Failures and Analysis:
1. Motor encoder alarm
1. The cause of the failure
(1) Wrong wiring;
(2) electromagnetic interference;
(3) Encoder hardware damage caused by mechanical vibration;
(4) Pollution caused by the on-site environment;
2. Troubleshooting
...
|
|
Mitsubishi Electric develops production line improvement technology
TOKYO, March 26, 2020 – Mitsubishi Electric Corporation (TSE: 6503) announced today that it has developed a new technology for efficient design and material flow of production floor layouts and accurate estimates ® of productivity using Mitsubishi Electric's Maisart *AI.
|
|
Mitsubishi servo motor realizes positioning function
The motion control command of the PLC realizes the perfect positioning function. Briefly describe the Mitsubishi PLC positioning instructions, which can be divided into origin regression instructions DSZR, ZRN, positioning instructions PLSY, PLSR, DRVI, DRVA, variable speed operation PLSV.3 In the meantime, PLSY and PLSR are pulse output instructions, and their positioning functions are relatively ...
|
|