The Rittal SE 8 system cabinet shows you what efficiency looks like

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

SE 8 system cabinet

Lightweight, yet still strong
The Rittal SE 8 system cabinet shows you what efficiency looks like

Industry applications are becoming increasingly complex, and there is a demand for low-complexity cabinet systems for efficient assembly in all industry applications. To meet the needs of the market, Rittal has launched the new SE8 freestanding enclosure.

SE 8 system cabinet

Dramatically reduce your installation time

Clever design

Installing the side panels? No, you don't! Self-supporting integral construction technology, the top and sides are a whole plate, and the stability performance is excellent.

High degree of protection (up to NEMA 4X)

Available in carbon steel and stainless steel, they are suitable for almost all areas of application

The internal installation is simple and time-saving

The side panels are roll-formed to minimize assembly effort

Compatible with the TS 8 Consolidation System for unified project management

Choose from a variety of sizes

Instead of two cabinets being combined, it adopts a single-piece monolithic design with a larger width

Cabinets range in width from 600 to 1800mm, with 1600 and 1800mm width cabinets limited to SE 8

Cabinets are available in 1600, 1800 and 2000 mm heights

Cabinet depths are 400, 500 and 600mm

Install whatever you want

Automatic potential equalization

The cable entry fits perfectly into the cabinet

A wide range of accessories based on the TS 8 system platform

Multiple base/base variant options: Flex-Block, cable chamber or steel or stainless steel standard base/base
More on that
Rittal cabinets – heat dissipation and dust protection for electrical cabinets Rittal cabinets – heat dissipation and dust protection for electrical cabinets

1. Built-in air conditioner for heat dissipation The cabinet is equipped with a refrigeration system, the evaporator and power devices are installed inside the cabinet in a closed manner, and the condenser and compressor are placed in the external circulation air duct or outside the cabinet. Since the power unit is sealed in the cabinet, as long as the appropriate sealant is used ...

Rittal enclosures – how to choose the size of the cabinet? Rittal enclosures – how to choose the size of the cabinet?

1. Determine the size of the server, such as depth size, height size (how many U), and whether it is a 19-inch rack-mounted installation. 2. Choose a cabinet according to the installation space: If the server is a 19-inch rack-mounted installation, then a standard cabinet can be used. Root...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is Peak Load? What is trough load? What is Average Load? A: Peak load refers to the maximum load that can occur on the grid and the user in a day. The trough load is the hourly average of the least amount of usage that occurs in the grid and the users in a single day.

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the basic requirements for a high-voltage circuit breaker? A: A. Reliable work; B. Have sufficient circuit breaking capacity C. Have the shortest possible cut-off time; D. Simple structure and low price. What is the purpose of the disconnector? Answer: A. Electrical...

How many fault codes does a Rittal cabinet air conditioner have? How many fault codes does a Rittal cabinet air conditioner have?

There are a total of 9 fault codes for Rittal cabinet air conditioners, They are: F1, F2, F3, FF, EH, EP, EL, SF, HC. Among them, F1, F2, and F3 represent improper use or failure of internal components; FF stands for Regulation Circuit Fault; EH stands for High Temperature Fault; E ...

Rittal cabinets – the operation process of power outages in low-voltage distribution cabinets Rittal cabinets – the operation process of power outages in low-voltage distribution cabinets

1. Normal power transmission operation process of low-voltage distribution cabinet: 1. All load switches are disconnected, confirm that the switches have at least one breakpoint; 2. Confirm that the power switch is in the disconnected position; 3. Send the power supply to the operation circuit, and the status indication is normal; 4. The incoming switch is - isolated ...

Rittal cabinet - judgment and treatment of high-voltage switchgear opening faults Rittal cabinet - judgment and treatment of high-voltage switchgear opening faults

Opening faults can also be divided into mechanical faults and electrical faults. Electrical faults mainly include open control loops, coil faults, auxiliary switch faults, etc. 1. Fault phenomenon: when the red light is not on, the electric cannot be opened, which is the fault of the auxiliary switch. When the opening coil burns out, there is smoke, odor, insurance ...

Rittal cabinets – what do you need to pay attention to when tidying up your cabinets? Rittal cabinets – what do you need to pay attention to when tidying up your cabinets?

1. In principle, the power cord and network cable of the cabinet should be sorted out separately; 2. The placement of the equipment should be appropriate, avoid squeezing each other, avoid being too high or too low, and avoid being too close to each other; 3. If there are too many devices in the cabinet, the equipment should be numbered; 4. For each line ...

Rittal cabinets - judgment and handling of common faults in high-voltage switchgear Rittal cabinets - judgment and handling of common faults in high-voltage switchgear

1. Judgment and treatment of sudden tripping fault of high-voltage switchgear during operation 1) Fault phenomenon: The cause of this failure is the protection action. The high-voltage cabinet is equipped with protection against overcurrent, quick cut-off, gas and temperature. 2) Judgment method: judging the cause of the fault can be based on the relay off, remote ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

Power distribution circuits? Answer: From the regional substation to the substation of the electricity unit or the power supply line of the city and township, it is the line used to distribute electric energy. Power lines can be divided into according to the erection method? A: Overhead power lines and cable lines. ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is eddy current? What are the harms of eddy currents? Answer: When an alternating current is passed through a wire, an alternating magnetic field is created around the wire. An induced current is generated inside the whole conductor in an alternating magnetic field, and because this induced current forms a closed loop inside the whole conductor, ...

Rittal innovates the Ri4Power top-of-the-line distribution cabinet system Rittal innovates the Ri4Power top-of-the-line distribution cabinet system

Ri4Power satisfies four specifications of the system Rittal Ri4Power has developed this concept as a complete system solution for the safe and fast installation of low-voltage switchgear for machines, systems and buildings. Rittal Ri4Power It is a device that covers high-current power distribution ...

Rittal cables – the common code for cables Rittal cables – the common code for cables

Usage code - not marked as power cable, K- (control cable), P- (signal cable); Conductor material code - not marked as copper (can also be marked as CU), L- (aluminum); Inner Sheath Code – Q-(Lead Packed), L- (Aluminum Cladding), H- (Rubber Jacket), V-(Polyvinyl Chloride ...

An introduction to the features of Rittal cabinet fans An introduction to the features of Rittal cabinet fans

Wide air volume range: 20-900m3/h Innovative diagonal flow fan and brushless DC EC motor technology for higher air flow and uniform distribution of cold air Comes with an interface module for controlling and monitoring fans The standard degree of protection is IP54, up to IP56 with a water spray cover ...

Advantages of Rittal cabinets Advantages of Rittal cabinets

1. Rittal cabinet can be divided into three series from the structure, ES cabinet (five-fold profile cabinet), PS cabinet (nine-fold profile cabinet), TS cabinet (sixteen-fold profile cabinet), the biggest feature is that the Rittal cabinet is the selection of profile structure structure, the structure of the cabinet is welded first, and then the top plate, bottom plate, side panel, door...

Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring

1. Site selection. The location of the low-voltage distribution room should be close to the load center, set up in a place with less dust, less corrosive medium, dry and slight vibration, and should appropriately leave room for development; Second, the layout of power distribution equipment. The layout of the distribution equipment in the low-voltage distribution room must follow the principle of safety, safety, and safety.

How to use Rittal cabinets How to use Rittal cabinets

1. Tie the cable tie at the beginning of the root of the cable with a cable tie, if there are too many cables, the number of the network cable is divided into two or many parts from the center, but the demand ensures that each part of the network cable is connected, because the next step is simple. 2. According to ...

What is the daily maintenance method of the air conditioner? - Rittal air conditioning What is the daily maintenance method of the air conditioner? - Rittal air conditioning

1. Filter maintenance of the indoor unit: The filter screen of the indoor unit generally needs to be replaced once every two months. It is not recommended to continue to use it after rinsing, because the rinsed filter is easy to stick, so that ventilation and ventilation are not smooth, and air circulation is affected. So if it's a one-off, direct replacement, not ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

How is an electric current formed? Answer: The free electrons in the conductor move regularly and directionally under the action of the electric field force, and an electric current is formed. What are the indicators of power quality? Answer: Voltage deviation, voltage fluctuation and flicker, voltage sine wave distortion rate, frequency deviation. ...

A basic introduction to a very popular explosion-proof box in Rittal A basic introduction to a very popular explosion-proof box in Rittal

As a commonly used box in Rittal, many users do not understand the material and structure of this series of boxes. Now I would like to introduce the Rittal explosion-proof enclosure Apply: – Zones 1 and 2 or Zones 21 and 22 according to 94/9/EG – Ambient temperature range: -30°C.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383