Rittal RBT cooling units – the most economical option for you! If a limited budget makes you extremely cost-conscious, then RBT is the choice for your ambition. After large-scale assembly line production and the excellent functions of the cooling unit itself, the RBT has achieved a very high price-performance ratio. Despite its affordable price, the RBT cooling unit is in no way inferior to other Rittal cooling products in terms of cooling functions, functional design and electronic control. Rittal RBT side-mounted cooling unit: ● Useful cooling output of up to 3000 W
● It can be installed neatly next to all cabinets
● High cooling power
● Optimize the airflow in the cabinet
● Built-in condensate transpiration device (type optional)
● CE certified
The Rittal RBT side-mounted cooling unit is particularly commendable in terms of a number of functional details:
● Can be easily installed on any suitable vertical panel
● The vent is equipped with a polyurethane filter to ensure clean air circulation
● The air outside the cabinet is directed to the upper part to achieve the optimization of the cooling effect
● Detachable filter and finger protection screen for external fans, faster and safer
● Full metal shell
● Environmentally-friendly refrigerant (R134a)
● Functional test specification DIN 3168/EN815/EN14511 to ensure useful refrigeration
talent
● Built-in transpiration device: Deal with condensate problems
|
More on that
|
Rittal cables – the meaning of the first letter of the number of the control cable
First of all, the number of the control cable often starts with the letter "C", which indicates that the control cable is specially designed to connect different sensors and control devices as a medium for signal transmission. This cable can transmit data signals and has a certain resistance to wear and chemical corrosion, so ...
|
|
Rittal X SF | Helping smart logistics airports set sail safely
Hello, your courier has been sent out and will be delivered tomorrow morning.
Perfect logistics network, intelligent sorting, digital control ...... The development of modern logistics has made logistics services increasingly efficient and fast, and timely delivery and next-day delivery are no longer slogans.
|
|
Rittal cabinets – the role of network cabinets and how to wiring them
What is a Network Cabinet?
The network cabinet is a kind of rectangular cabinet composed of two parts: frame and cover, which can install switches, optical fiber adapters, optical fiber distribution frames and other equipment in a cabinet, with electromagnetic isolation, noise isolation, ventilation and heat dissipation, anti-vibration, anti-corrosion, etc.
|
|
Rittal cables – common faults in power cables
Short-circuit fault: There are two-phase short circuits and three-phase short circuits, which are mostly caused by hidden dangers left in the manufacturing process.
Grounding fault: one or more cores of the cable break down to the ground, and the insulation resistance is lower than 10kΩ is called low-resistance grounding, and higher than 10kΩ is called high-resistance grounding. Mainly due to cable corrosion, lead ...
|
|
What factors need to be taken into account when choosing a Rittal cabinet – outdoor enclosure?
1. Safety: As the carrier of electrical equipment, the outdoor cabinet must have excellent structural design, solid materials, and firm bottom fixation to meet the requirements of strong typhoons, strong rainstorms, and even strong earthquakes. At the same time, the cabinet should have anti-leakage, anti-short circuit, anti-cut and other requirements.
2. Rainproof and dustproof ...
|
|
Rittal cabinet - knowledge quiz of high and low voltage distribution cabinet (41-50)
41. Can power lines be divided into according to the erection method?
A: Overhead power lines and cable lines.
42 What is a protective relay?
Answer: It can reflect the failure or abnormal operation of electrical equipment in the power system, and act on the switch to trip or send out a signal ...
|
|
The solution to the A17 fault reported by the Rittal cabinet air conditioner
1. The Rittal air conditioner does not start when it is turned on, and the A17 is faulty.
Check that the power supply voltage is 220V, normal; Detect that the battery voltage of the remote control is 3V, which is normal; Measure the fuse resistance value of the air conditioner compressor with a multimeter as infinity, which is normal.
2. The Rittal air conditioner does not start when it is turned on, and the display is not started.
|
|
Rittal enclosures – operating precautions for low-voltage distribution cabinets
First, set posts and responsibilities. The power department of distribution box equipment should number, register, file, hierarchical management, clear responsibilities, and regularly carry out technical inspection and maintenance of the distribution box.
|
|
Rittal Cables – an introduction to the performance of industrial control cables
Thermal function: Due to the existence of thermal expansion and contraction, we should also pay attention to the thermal function of industrial control cables, that is, the temperature resistance level of industrial control cables, the heating and heat dissipation characteristics of cables for power transmission at working temperatures, current carrying capacity, short circuit and overload capabilities, the thermal deformation and thermal impulse resistance of the constituent materials.
|
|
A detailed presentation of Rittal's new smart electronic lock
With the development of data centers in the direction of more intelligent and high reliability, the information stored in the servers in the IT cabinet is becoming more and more important, and the operation and maintenance of the data center needs to be able to manage the door opening of the cabinet more effectively to avoid server downtime caused by human factors.
Traditional Mechanical Cabinet Locks ...
|
|
Rittal cabinet - distribution cabinet installation method, installation process and precautions
First, the construction process
Equipment unpacking inspection→ equipment handling, → cabinet (plate), basic installation, → above the cabinet (plate), bus preparation, → cabinet (plate), secondary circuit wiring, → cabinet (plate) test adjustment, → power transmission operation acceptance
Second, the construction process
1. Equipment unpacking inspection, installation ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the advantages of microcomputer automatic monitoring?
Answer: The device is small in size, high in reliability, has the functions of information storage, memory, calculation and logical judgment, and can collect, process, print and display the data.
What is overvoltage?
Answer: Put the pair of insulated ...
|
|
Running seamlessly, Rittal develops with reliable quality "pulsating" energy storage
Reliable supply wherever you are
Tesvolt's large-scale industrial battery storage systems are based on standard products made by Rittal and guarantee a continuous power supply on the top of a mountain, by the sea or in the desert.
The mountain peaks rise high above the crystal clear ...
|
|
Rittal Cables – the operation of power cable routes
The operating voltage of the cable
Generally speaking, there is a certain relationship between the operating voltage of the cable and the rated voltage. If some cable lines are not in use, they must be connected to the power grid to ensure that the cable lines are not exposed to moisture. When the neutral point is not grounded ...
|
|
Rittal Cables – precautions for the installation and wiring of control cables
Precautions for the installation and wiring of control cables:
1. Under the eaves. Cables can only be used if they are not directly exposed to sunlight or ultra-high temperatures, and it is recommended to use pipes. Ultraviolet (UV) – Do not apply cables without UV protection to direct sunlight rings ...
|
|
Rittal cables – classified according to the purpose of the cable and the environment in which it will be used
1. DC cable
(1) Tandem cables between components.
(2) Parallel cables between strings and between strings and DC distribution boxes (combiner boxes).
(3) The cable between the DC distribution box and the inverter.
The above cables are all DC cables, outdoor laying ...
|
|
Rittal cabinets – maintenance methods for low-voltage distribution cabinets
1. The purpose is to ensure the normal and safe operation of the low-voltage distribution cabinet and the control cabinet of each equipment.
Second, the scope is suitable for the low-voltage distribution room distribution cabinet, and the control cabinet of each equipment shall be implemented with reference to the relevant provisions according to the specific situation.
Third, the responsibility of the mechanical and electrical installation and maintenance engineering department maintenance team every six months ...
|
|
Rittal Cables - Introduction to the performance characteristics of control cables
1. DC resistance: 20°C, 0.4mm copper wire, less than or equal to 148Ω/km, 0.5mm copper wire, less than or equal to 95Ω/km.
2. Insulation electrical strength: 1min 1kv between conductors does not break down, conductors and shields 1min 3kv do not break down
3. Insulation resistance: each core and the rest of the core ...
|
|
To help industrial upgrading with ingenuity and quality, Rittal and liquor companies talk about smart brewing
China has a long history of winemaking. "Shuo Wen Jie Zi" once said: The ancients Yi Di made wine mash, Yu tasted it and was beautiful, so Yi Di was sparse. Du Kang made rice wine.
Counting from the Yu period, liquor has a history of more than five or six thousand years in China, it is not only the inheritance of good taste, but also the long history of the Chinese nation.
|
|
Rittal Cables – the main classification of wires and cables
Bare wire body products
The main characteristics of this type of products are: pure conductor metal, no insulation and sheath layer, such as steel core aluminum stranded wire, copper-aluminum busbar, electric locomotive line, etc.; The processing technology is mainly pressure processing, such as smelting, calendering, drawing, stranding/pressing stranding, etc.; The main products ...
|
|