Rittal Cables – the operation of power cable routes

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

The operating voltage of the cable

Generally speaking, there is a certain relationship between the operating voltage of the cable and the rated voltage. If some cable lines are not in use, they must be connected to the power grid to ensure that the cable lines are not exposed to moisture. In the event of a single-phase grounding when the neutral point is not grounded, the run time should be limited to less than 2 hours.

The operating temperature of the cable

From the perspective of the operation effect of the cable, if the cable running speed is too large, the temperature will rise, and the insulation and aging degree of the cable line will continue to improve. In addition, if the temperature of the cable route is too high, thermal expansion will occur. In severe cases, voids inside the cable can be formed, which will be free for a long time, and can also be directly damaged.

Therefore, during the operation of the cable, the staff should control the temperature of the conductor part of the cable core. In the case of the core of a 110KV oil-filled cable, its temperature should be controlled within the standard temperature range. However, since the temperature of the cable core cannot be measured, the staff should judge the temperature of the cable core based on the surface temperature of the cable. In general, the surface temperature difference should be controlled to around 15°C.

In addition, in the process of temperature measurement, the surveyor needs to take corresponding measures to limit the load, and the cables above and below the ground are inspected.

The operating load of the cable

Different cables ride in the voltage environment to operate the load is also different, under normal circumstances, the load is not allowed to be too large, but for the regular load current, less than the longest operating current can be used in a short period of time to meet the excess. In the case of cables less than 10KV, the maximum load current must not be greater than 110% of the rated current, and the residence time must not exceed 2 hours.

Other requirements for cable operation

In the process of cable operation, a reclosing structure is usually set up. After the circuit breaker trips, power cannot be sent directly. Mainly due to the permanence of the operation of the line, the staff needs to ensure the correctness of the phase after the cable line is connected.

The temperature of the cable is best measured in the summer, when the load on the cable route is greatest. In addition, in the process of application at the head and middle of the cable, it is not allowed to be electrified. If there is smoke in the cable or cable head, the staff should cut off the power supply as soon as possible and do a good job of extinguishing the fire.
Rittal Cables – the operation of power cable routes

More on that
Rittal cabinet - judgment and treatment of sudden trip fault in operation of high-voltage switchgear Rittal cabinet - judgment and treatment of sudden trip fault in operation of high-voltage switchgear

1) Fault phenomenon: The cause of this failure is the protection action. The high-voltage cabinet is equipped with protection against overcurrent, quick cut-off, gas and temperature. 2) Judgment method: The cause of the fault can be judged according to the relay card drop, remote signaling information, etc. After the action of gas and temperature protection in the high-voltage cabinet ...

Rittal wall-mounted air conditioner with high energy efficiency Blue e+ 1.6-5.8 kW with an average energy saving of 75% Rittal wall-mounted air conditioner with high energy efficiency Blue e+ 1.6-5.8 kW with an average energy saving of 75%

Rittal wall-mounted air conditioner Blue e+ 1.6-5.8 kW Product model 3185.830 The energy-efficient Blue e+ wall-mounted cooling unit with capacities ranging from 1600 W to 5800 W. Energy savings of 75% on average due to the use of speed control components and heat pipe technology. There are carbon steel and ...

Rittal won the Best Partner Award from Hengxin Software and Yokogawa Automation Rittal won the Best Partner Award from Hengxin Software and Yokogawa Automation

Sincere service, strength and responsibility In 2022, which was full of changes, Rittal and its partners Hengxin Software and Yokogawa Automation (part of the Yokogawa Group) withstood the challenges brought about by the pandemic and moved forward hand in hand. In the cooperation project, Rittal worked with the customer to overcome difficulties and complete the project delivery in a timely manner, ...

Rittal Cables – an introduction to the structure of industrial control cables Rittal Cables – an introduction to the structure of industrial control cables

1. Conductor It is the main component of the product to play its use function, and it is to transmit electricity or information, that is, to transmit electric current or electromagnetic waves on the conductor. The conductor is the basic and indispensable main component of the product for the transmission of electric current or electromagnetic wave information. 2. Insulation ...

Rittal cabinets - knowledge quiz on high and low voltage distribution cabinets (31-40) Rittal cabinets - knowledge quiz on high and low voltage distribution cabinets (31-40)

31. How many modes are there for the three-phase neutral point operation of China's power system? Answer: 1. Three-phase system with no grounding (insulation) at the neutral point; 2. Three-phase system in which the neutral point is grounded through the arc suppression coil; 3. Three-phase system with direct grounding at the neutral point. 32. Use current transformers ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is Phase Order? Answer: It is the order of the phases, which is the sequence in which the instantaneous value of alternating current changes from negative to positive through zero What is the safety distance of the human body grounding point when a grounding fault occurs in high-voltage equipment? A: Indoor should be larger than 4 m, outdoor should be larger than 8 ...

An introduction to the features of Rittal cabinet fans An introduction to the features of Rittal cabinet fans

Wide air volume range: 20-900m3/h Innovative diagonal flow fan and brushless DC EC motor technology for higher air flow and uniform distribution of cold air Comes with an interface module for controlling and monitoring fans The standard degree of protection is IP54, up to IP56 with a water spray cover ...

Rittal cables – common causes of cable failure Rittal cables – common causes of cable failure

1. External force damage. Judging from the operation analysis in recent years, especially in Haipudong, which is developing rapidly, a considerable number of cable failures are caused by mechanical damage. For example, the cable laying and installation is not standardized, which is easy to cause mechanical damage; Engage in direct burial on cables ...

Rittal cabinets – the uses and characteristics of commonly used low-voltage distribution cabinets Rittal cabinets – the uses and characteristics of commonly used low-voltage distribution cabinets

▲ GGD AC low-voltage distribution cabinet: (1) Use GGD type AC low-voltage distribution cabinet is suitable for substations, power plants, factories and mining enterprises and other power users AC 50Hz, rated working voltage 380V, rated working current 1000-3150A distribution system, as a power ...

What are the main classifications of Rittal cables – power cables? What are the main classifications of Rittal cables – power cables?

Classified by voltage level According to the voltage level, it can be divided into medium and low voltage power cables (35 thousand volts and below), high-voltage cables (above 110 thousand volts), ultra-high voltage cables (275-800 thousand volts) and ultra-high voltage cables (1000 thousand volts and above). In addition, it can also be divided into AC ...

What do you need to pay attention to when grounding the electrical control cabinet? What do you need to pay attention to when grounding the electrical control cabinet?

1. Make sure that all equipment in the electrical control cabinet is well grounded, and use short and thick grounding wires to connect to the common grounding point or grounding busbar. Any control equipment connected to the inverter should be co-grounded with it, and likewise ground with short and thick wires; 2. Flat conductors are used, e.g. ...

Rittal cables - the key points for the purchase of wires and cables Rittal cables - the key points for the purchase of wires and cables

1. Look at the packaging, the wires of the national standard are often better, neat, and have a sense of quality when you hold them. 2. To open the package and take a look at the wires inside, the wire requirements of the national standard wire 1.5——-6 square are required to be skin thickness (insulation thickness) is 0.7mm, and too thick is non-standard.

Rittal cabinets – what are the technical requirements for the cabinets? Rittal cabinets – what are the technical requirements for the cabinets?

1. It should have good technical performance. The structure of the cabinet should be designed according to the electrical and mechanical properties of the equipment and the requirements of the use environment, so as to ensure that the structure of the cabinet has good stiffness and strength, as well as good electromagnetic isolation, grounding, noise isolation, ...

Here's a quick overview of what products Rittal makes Here's a quick overview of what products Rittal makes

Many customers don't know what products Rittal makes, so today I will simply classify Rittal products. Rittal products are mainly divided into 6 categories below 6 (1) Rittal control cabinet: small cabinet (here can also be subdivided polycarbonate cabinet PK, junction box KL, compact control box EB, ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the classifications of different electrical experiments according to their roles and requirements? A: It can be divided into insulation test and characteristic test. What are the factors that affect the degree of harm to the human body of electric shock? Answer: The magnitude of the current, the duration of the current, the path of the current, the resistance of the human body, and the ...

Rittal cables – the difference between power cables and control cables Rittal cables – the difference between power cables and control cables

The power cable is used to transmit and distribute large-scale electrical energy in the main line of the power system, and the control cable directly transmits the electric energy from the distribution point of the power system to the power connection line of various electrical equipment and appliances. The rated voltage of power cables is generally 0.6/1KV and above, and the control cables are mainly 4 ...

Rittal enclosures – types of sheet metal enclosures Rittal enclosures – types of sheet metal enclosures

In terms of structure, there are two ways to classify sheet metal cabinets: According to the division of the cabinet frame, it can be divided into the whole plate type and the column and beam combination type; According to the way of cabinet angle connection, it can be divided into four forms: adhesive connection, screw connection, pin connection and welded connection. ...

Rittal cabinets – how network cabinets are organized and maintained Rittal cabinets – how network cabinets are organized and maintained

1. Preparation First of all, the user should be notified to organize the cabinet without affecting the normal operation of the user. Then, according to the topology of the network, the existing equipment, the number of users, the user group and other factors, the wiring diagram and equipment inside the cabinet are outlined.

The customized outdoor cabinet of the Rittal integrated pumping station was successfully delivered to build an ecological water environment The customized outdoor cabinet of the Rittal integrated pumping station was successfully delivered to build an ecological water environment

The handover ceremony of the customized outdoor cabinet of the integrated pumping station jointly developed by Rittal and Shu Pengshi was held in Rittal (China) Company. Mr. Tian Ming, General Manager of Shupenshi Environmental Technology (Changzhou) Co., Ltd., and Mr. Xue Boliang, Technical Director, attended the handover ceremony with technical engineers. Power...

Rittal takes you through the efficient and accurate configuration of your enclosure system Rittal takes you through the efficient and accurate configuration of your enclosure system

In the recent Winter Olympics, short track speed skating star Wang Meng helped lock the first gold medal of the Chinese team in the Winter Olympics in advance with "My eyes are rulers". So what is the "magic weapon" that can help engineers refine the "sharp eye" of error-free assembly in the assembly of Rittal cabinet systems? ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top