The model of the power cable
1. Use the capitalization of the first letter of Hanyu Pinyin to indicate the type of insulation, conductor material, inner sheath material and structural characteristics. For example, Z is used to represent paper (zhi); L stands for Aluminum (LV); Q is for lead (qian); F stands for fen; ZR stands for flame retardant (zuran); NH stands for refractory (naihuo).
2. Use numbers to indicate the composition of the outer sheath, with two digits. No number means no armor layer, no outer coat. The first digit indicates the armor, and the second digit indicates the outer coat, such as the outer jacket of the coarse steel wire armor fiber is represented as 41.
3. The cable model is generally arranged in order according to the cable structure: insulating material; conductor materials; inner sheath; Outer sheath.
4. Cable products are expressed by model number, rated voltage and specifications. The method is to add a description of the rated voltage, the number of cores and the nominal cross-sectional area to the model number.
Detailed description of the model
(1) Category: H - intra-city communication cable
HP – Wiring Cables
HJ - local cable
(2) Insulation: Y-polyethylene insulation
YF – Foam polyolefin insulation
YP – Foam/Solid Skin Polyolefin Insulation
(3) Inner sheath: A - plastic-coated aluminum tape bonding shielding polyethylene sheath
S - Aluminum, steel double metal with shielding polyethylene sheath
V - PVC sheath
(4) Features: T - petroleum paste filling
G - High frequency isolation
C - self-supporting
(5) Outer sheath: 23 - double-layer anticorrosive steel strip wrapping polyethylene outer coat
33--Single-layer thin steel wire armored polyethylene quilt layer
43-Single-layer coarse steel wire armored polyethylene quilt layer
53 - single-layer steel strip wrinkled longitudinal wrap armored polyethylene outer coat
553 - double-layer steel strip wrinkled longitudinal wrap armored polyethylene coat
2) BV copper conductor PVC insulated wire;
BLV aluminium core PVC insulated wire;
BVV copper conductor PVC insulated PVC sheathed wire;
BLVV aluminum core PVC insulated PVC sheathed wire;
BVR copper conductor PVC insulated flexible wire;
RV copper conductor PVC insulated installation cord;
RVB copper conductor PVC insulated flat connecting wire, flexible wire;
BVS copper conductor PVC insulated stranded flexible wire;
RVV copper conductor PVC insulated PVC sheathed flexible wire;
BYR Polyethylene Insulated Flexible Wire;
BYVR polyethylene insulated PVC sheathed flexible wire;
RY polyethylene insulated flexible wire;
RYV polyethylene insulated PVC sheathed flexible wire
3) WD: halogen-free and low-smoke type
ZR: Flame retardant
NH: Refractory type
DH: Fireproof type
|
More on that
|
Precautions for the use of Rittal electrical cabinets
1. When the electrical cabinet is used, the shell should be reliably grounded, and the electrical parts should be comprehensively inspected to eliminate the phenomenon of leakage and open circuit that may be caused by long-distance transportation, and check whether the voltage is consistent with the working voltage.
2. The electric cabinet is a non-explosion-proof oven, so it is flammable, explosive, volatile and corrosive.
|
|
Rittal Nonwovens filter mats product description
Product Introduction
Product name: Rittal Rittal
Product Type: Rittal Non Woven Filter Mats
Product Model: 3172.105
Spare filter mats for top-mounted fans, filter fans or thermoelectric coolers to protect control cabinet components from dirt, ash ...
|
|
Rittal cables – the basic structure of power cables
1. Core: The core is the conductive part of the power cable, which is used to transmit electric energy and is the main part of the power cable.
2. Insulation layer: The insulation layer is to electrically isolate the core from the ground and the cores of different phases to ensure the transmission of electric energy.
|
|
Rittal cables – the difference between power cables and control cables
The power cable is used to transmit and distribute large-scale electrical energy in the main line of the power system, and the control cable directly transmits the electric energy from the distribution point of the power system to the power connection line of various electrical equipment and appliances. The rated voltage of power cables is generally 0.6/1KV and above, and the control cables are mainly 4 ...
|
|
Rittal cabinets – what are the technical requirements for the cabinets?
1. It should have good technical performance. The structure of the cabinet should be designed according to the electrical and mechanical properties of the equipment and the requirements of the use environment, so as to ensure that the structure of the cabinet has good stiffness and strength, as well as good electromagnetic isolation, grounding, noise isolation, ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the precautions for using current transformers?
Answer: 1. The secondary side shall not be open when working; 2. One end of the secondary side must be grounded; 3. The polarity of the terminal should be paid attention to when connecting.
What are the precautions for using voltage transformers?
A:1. When working, its secondary side shall not be short-circuited ...
|
|
Rittal Cables – What do you need to pay attention to when wiring industrial control cables?
1. The weight of the cable in the industrial control cable drag chain should be evenly distributed, so as to avoid accidents caused by uneven weight during operation, and the principle of distributing the cable is that the heavier one is located on both sides and the lighter one is located in the middle. All industrial control cables must be securely fastened to one end of the energy chain, so that ...
|
|
Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring
1. Site selection. The location of the low-voltage distribution room should be close to the load center, set up in a place with less dust, less corrosive medium, dry and slight vibration, and should appropriately leave room for development;
Second, the layout of power distribution equipment. The layout of the distribution equipment in the low-voltage distribution room must follow the principle of safety, safety, and safety.
|
|
Rittal cables – what are the common cable faults?
Wire surface marking - according to the national standard, the wire surface should have the manufacturer name, product model and rated voltage continuous marking. This is conducive to finding the manufacturer in time when problems occur during the use of wires, and consumers must pay attention to this when purchasing wires. At the same time consume ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is the role of a DC system in a substation?
Answer: The DC system provides reliable DC power supply for control signals, relay protection, automatic devices and accident lighting in the substation, and also provides reliable operating power for operation. The reliability of the DC system has a significant impact on the ...
|
|
Rittal cabinets – what do you need to pay attention to when tidying up your cabinets?
1. In principle, the power cord and network cable of the cabinet should be sorted out separately;
2. The placement of the equipment should be appropriate, avoid squeezing each other, avoid being too high or too low, and avoid being too close to each other;
3. If there are too many devices in the cabinet, the equipment should be numbered;
4. For each line ...
|
|
Rittal cabinet fittings Rittal stainless steel rain cover for AE model 2472.000
Stainless steel rain top cover for AE
Product model 2472.000
Outdoor fixtures are safely and reliably protected with a drain channel at the back. Material: Stainless steel 1.4301 (AISI 304).
Product Description: Safe and reliable protection for outdoor installations, with ...
|
|
Rittal Cables – what are the ways to lay wires and cables?
1. Buried laying
The laying method of laying the cable immediately underground is called buried laying. The buried cable must be armored cable and anti-corrosion coating protection cable, and the bare cable cannot be buried. Generally, the depth of the cable trench shall not exceed 0.9m, and the buried laying shall be paved ...
|
|
Rittal enclosures – how to choose the size of the cabinet?
1. Determine the size of the server, such as depth size, height size (how many U), and whether it is a 19-inch rack-mounted installation.
2. Choose a cabinet according to the installation space: If the server is a 19-inch rack-mounted installation, then a standard cabinet can be used. Root...
|
|
Alarm code causes and diagnostic methods for Rittal cabinet air conditioners
Alarm code: A01
System message: Open the cabinet door
The cause of the Rittal air conditioner: the opening and closing of the door is not in the correct position
Diagnostic method: Check the changing position of the door and, if necessary, the connection status
Alarm code: A02
System message: The temperature in the cabinet is too high
...
|
|
What are the advantages of Rittal cables – power cables?
1. It occupies a small area. Generally, it is buried in the soil or laid indoors, ditches, tunnels, with a small insulation distance between lines, no towers, less land occupation, and basically no land on the surface.
2. High reliability. It is less affected by climatic conditions and surrounding environment, and the transmission performance is stable and the reliability is high. ...
|
|
What are the common faults of Rittal cables – control cables?
1. The impact of lightning
The armor components of the control cable are all metal conductors, and if the power line is short-circuited or lightning hits the metal parts, a strong current will be generated to destroy the optical cable line equipment, and even casualties will occur in serious cases.
2. Optical cable ...
|
|
Rittal X SF | Helping smart logistics airports set sail safely
Hello, your courier has been sent out and will be delivered tomorrow morning.
Perfect logistics network, intelligent sorting, digital control ...... The development of modern logistics has made logistics services increasingly efficient and fast, and timely delivery and next-day delivery are no longer slogans.
|
|
Rittal wall-mounted air conditioner with high energy efficiency Blue e+ 1.6-5.8 kW with an average energy saving of 75%
Rittal wall-mounted air conditioner Blue e+ 1.6-5.8 kW
Product model 3185.830
The energy-efficient Blue e+ wall-mounted cooling unit with capacities ranging from 1600 W to 5800 W. Energy savings of 75% on average due to the use of speed control components and heat pipe technology. There are carbon steel and ...
|
|
How to choose a distribution box for home renovation - Rittal
1. Determine the material of the distribution box
First of all, from the material selection, the distribution box on the market is divided into plastic and metal two materials, metal material is durable, strong resistance, but it is easy to rust and corrode when encountering water stains; Although plastic is light and cheap, it is not very durable. Therefore the root ...
|
|