One of the characteristics of the Wiener low-voltage switchgear is the multi-functional busbar system. The bus bar is a conductor that connects large electrical equipment such as generators and transformers with various electrical devices. The role of the bus bar is to transmit electric energy with the, and the bus bar is the main equipment constituting the electrical wiring. Today, Hangzhou Weiner Electric Co., Ltd. will tell you about the technical key of the main bus in the low-voltage switchgear.
Now special-shaped main bus is widely used in low-voltage switchgear, such as MNS rear outlet cabinet using "I" shaped main bus. The technical key to the main bus in the low-voltage open light cabinet is:
1. Focus on improving the bending strength of the bus system and improving the ability of the main bus to resist short-circuit current;
2. The non-porous connection between the branch bus and the main bus bar is selected, which simplifies the assembly method of the bus system. Together, the branch bus and the drawer circuit also choose the plugging method without punching, which facilitates the use and protection of the low-voltage switchgear.
The bus system is an important part of the low-voltage switchgear. The bus system determines the electrical parameters such as the thermal stability of the low-voltage switchgear, the inlet and outlet methods of the low-voltage switchgear, the connection method of each main circuit, and the heating of the low-voltage switchgear.
|
More on that
|
220V DC Hazard of Bus System – Wiener
The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system.
In the DC system, the positive and negative poles of the DC are insulated from the ground, and when the ground of one pole is generated, there is no grounding current due to the fact that there is no grounding current.
|
|
220V DC Hazard in Busbar System – Wiener
The grounding of the DC system should include two conditions: the one-point grounding of the DC system and the two-point grounding of the DC system.
In the DC system, the positive and negative poles of DC are insulated from the ground, and they do not cause any harm when generating a ground current because there is no path to constitute a grounding current, but the ground of one pole is long.
|
|
Introduction to the Wiener data center bus system
Although the service life cost of the bus system is usually lower than that of the traditional wiring method, the bus system still bears a considerable cost compared with other structural elements of the water supply and drainage or HVAC system.
In addition, customized busbar equipment allows the busbar system to be routed around obstacles ...
|
|
Wiener DC power supply busway classification
In general, the DC power supply system is composed of a communication screen, a rectifier screen, and a DC screen. After selecting a dense bus duct, it is necessary to adjust the conventional DC power supply system: one or two large-capacity DC split-screens are installed in the communication room, and a large loop output is set in the DC split-screen; In the power room ...
|
|
The operation procedure of the dual power supply automatic transfer switch
The dual-supply ACT is a new generation of products. Beautiful appearance, good quality, long life, simple It is composed of two three-pole or four-pole shell graders and their parts/mechanical interlocking transmission arrangements, intelligent controllers, etc., which are divided into two structures: integral and split.
|
|
Distribution cabinet bus connection method - Wiener
When users use the distribution cabinet, they must understand the circuit device of the busbar, and many users are not very well understood, so let's talk about the bus connection mode of the distribution cabinet.
The bus bar is used for the internal and external electrical appliances of the distribution cabinet.
|
|
The application of Wiener bus system wiring technology in box transformer
The bus system is to directly connect the components to the bus, the bus does not need to be perforated, at this time, the bus is not only the conductor of the component, but also the support of the component, the current can reach 2500A, so that the box transformer function has the following progress:
1 ...
|
|
Characteristics of single bus wiring in the switchgear - Wiener
In power distribution equipment such as voltage distribution cabinets and switchgear at all levels of power plants and substations, the conductors connected between large electrical equipment such as generators and transformers and various electrical equipment are called busbars. Busbars, also known as busbars, are used to gather, distribute, and transmit electrical energy. The connection methods of the bus bar are ...
|
|
The difference between busway and busbar - Vernal
The busway and busbar are actually closed one after the other, and the other is not closed.
Closing the busbar is referred to as the busway, which means that the busway is the vest that closes the busbar, and the closing busway and the busbar refer to the same thing.
...
|
|
Busbar differential protection switching operation – Wienal
1. Whether the maintenance scale of the bus differential is confirmed, and whether the maintenance target is unchanged
Generally, differential maintenance includes bus differential maintenance, transformer differential maintenance, generator differential maintenance and line differential maintenance. The basic principle of completing differential maintenance is the same, that is, each side or each ...
|
|
Advantages of pluggable busway
1. The plug-in bus duct has strong overload capacity
The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105 is selected for the insulation data used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed.
|
|
Advantages of a shared DC bus system – Wienal
The shared DC bus system is the future development direction in the application of multi-drive motors, which makes reasonable use of the regenerative energy of the system together with better dynamic and static functions and speed regulation accuracy, eliminating a lot of braking units and braking resistors, and the energy efficiency ratio of the system has been greatly improved.
|
|
Laminated busbar system – Wiener
In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar.
...
|
|
The advantages of busway are used in cable tray installations
At the time of the cable tray installation, the wiring is not very convenient. This phenomenon can be avoided by using busway. The 5 advantages of using busway in the cable tray device are as follows:
1. Convenient connection of bus duct: the so-called plug-in bus...
|
|
Wiener looks at the busway drawing method
First, in the CAD system drawing, it is a plan of the bus duct, and two parallel polylines can indicate the bus duct.
2. The busway includes the following parts:
1. Feeder busbar, which is used to transmit electricity
2. Plug-in busbar with plug-in interface above, ...
|
|
The advantage of busway over cable in construction - Wienal
Modern power supply lines play a very important role like the aorta of the human body, and if something goes wrong, it can have serious consequences. Before the 80s of the 20th century, many stable cables were used in modern construction. With the rapid development of the city, the power load of the building ...
|
|
Busbar system reverse operation – Wiener
1. For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this moment, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a smaller one, so as to facilitate the bus tie circuit breaker when there is a problem, the bus tie circuit breaker can quickly trip, cut ...
|
|
Connector box features of the busbar system – Wiener
1. Rapid device
Today, busway adapters cannot be flipped at the time of installation, and the two busway sections are not out of phase when flipped when connected.
2. High protection level
The coupling box has a protective function, ...
|
|
Precautions for terminal block wiring - Wiener
1. The fastening wiring force should be moderate, avoid sliding the bolts and nuts with excessive force, and replace the bolts and nuts that have been slid in time, and prohibit the operation.
2. When tightening or loosening the screws with a screwdriver, it is necessary to force the screws to ...
|
|
Difference Between Grounding Electrode and Grounding Busbar – Vernal
The grounding electrode is a discharge channel that connects current or voltage to the earth, and in order to reduce the grounding resistance, the electrodes that form the grounding grid are generally used in groups.
The grounding bus refers to the connecting wire that connects the current or voltage to the grounding grid, or the conductor that connects the grounding electrode into one.
...
|
|