Interpretation of Reynolds inverter models

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

Take the RNB2000 series inverter as an example.

                               Interpretation of Reynolds inverter models

The model number of the RNB2000 series 37kW inverter is: RNB2037-U

RN: on behalf of Reynolds;

B: low-voltage frequency conversion governor;

2: 2000 series;

037: The power of this inverter is 37kw;

-U: indicates the special inverter for oilfield pumping unit. -Z indicates the main line drive inverter in the paper industry, -Q indicates the special inverter for lifting, and the default represents the general machine and so on.
More on that
How to deal with the inlet water of the inverter - Reynolds How to deal with the inlet water of the inverter - Reynolds

Inverters are widely used in all walks of life, in a variety of applications, inverters will inevitably encounter rainy and humid climate, resulting in internal wetness, or accidentally into the water, in fact, as long as it is found in time, it can still be rescued. If it is in the unpowered state ...

Protection feature of overcurrent trip - Renol Protection feature of overcurrent trip - Renol

1. Maintenance objectives of overcurrent In the frequency conversion speed regulation system, there are two devices: the frequency converter and the motor. The degree of tolerance to overcurrent is not the same. The planners of the production machinery decide on the capacity of the motor based on the principle of heat. That is, as long as the electricity ...

The reason why the inverter controls the motor – Reynolds The reason why the inverter controls the motor – Reynolds

Q1: Why should I use VFD to control the motor? When it comes to this issue, let's take a brief look at these two devices. The motor is an inductive load that hinders the change of current, and when it is started, a large change in current is generated. VFD, which is actually made up of a rectifier inverter circuit, ...

General Purpose Inverter Repair Inspection – Reynolds General Purpose Inverter Repair Inspection – Reynolds

The first step is to check whether the appearance of the inverter is defective, including whether the indicator light is in normal operation, whether the mission control function of the operation panel is complete, and carefully observe the appearance of the inverter under the operating condition, and do the corresponding recording operation; When repairing the inverter, check whether the voltage value and current value exceed the ...

The difference between frequency converter and power saver - Reynolds The difference between frequency converter and power saver - Reynolds

Many people don't have a clear idea of the detailed differences and uses of AC converters and power savers. Power savers are generally divided into lighting appliances and power savers. Using high-voltage filtering and energy absorption skills, it automatically absorbs the energy of the reverse potential of high-voltage power equipment, and continuously feeds back ...

Inverter: The right inverter to use - Reynolds Inverter: The right inverter to use - Reynolds

Low pressure issues The VFD reports a low voltage issue when the drive's DC link voltage drops below 62% of the nominal level at the high setting (480 Vac) and 50% of the nominal value at the low setting (400 Vac). The +10% and -15% voltage tolerances in most manuals are the ones that claim to be ...

Reynolds EPS emergency power supply routine maintenance Reynolds EPS emergency power supply routine maintenance

1. EPS the first use of the emergency power supply, the battery pack should be charged continuously for 48 hours after discharging protection; 2. EPS emergency power supply to keep the whole machine dry, clean, free of dust and foreign objects, wipe with a soft cloth after shutting down, and strictly ...

Precautions for the use of frequency converters - Reynolds Precautions for the use of frequency converters - Reynolds

In order to ensure the safe, efficient and reliable operation of the inverter, the following keys should be grasped when using the inverter: 1) It is necessary for the grounding terminal of the inverter to be firmly grounded, so as to effectively press the radio frequency disturbance and enhance the reliability of the system: the frequency conversion speed regulation system is best to use independent grounding, grounding resistance...

Inverter control method - Reynolds Inverter control method - Reynolds

The output voltage of low-voltage general frequency conversion is 380-650V, the output power is 0.75-400kW, and the operating frequency is 0-400Hz. Its control methods have gone through the following four generations. 1U/f=C Sinusoidal Pulse Width Modulation (SPWM) Manipulation MethodIts Characteristics ...

Reynolds drive control panel description Reynolds drive control panel description

1. FUN button; Press the FUN button to enter the settings menu F00; 2. Press and hold the up button or down button to scroll to the code that needs to be set; 3. Press the FUN button to confirm at this moment, and adjust the entry parameters to the required value; 4、 ...

Inverter maintenance power-on test instructions - Reynolds Inverter maintenance power-on test instructions - Reynolds

First, the inverter is not repaired and the power test is tested (1) Inverter repair test rectifier circuit At the two ends of the inverter to detect the internal DC power supply, P and N ends, adjust the multimeter to the resistance RX10 gear, the red watch pen is connected to the P end, and the black watch pen is connected to R, S, T, and there are tens of ohms under normal conditions.

How to measure a frequency converter with a multimeter – Reynolds How to measure a frequency converter with a multimeter – Reynolds

How to use a multimeter to measure the quality of the inverter, it needs to be noted that for personal safety, it is necessary to ensure that the machine is powered off, and remove the inverter input power line R, S, T and output line U, V, W before operation! First of all, the multimeter is hit to the "secondary pipe" file, and then through the multimeter ...

The cause of overheating of servo motor bearings - Reynolds The cause of overheating of servo motor bearings - Reynolds

The motor itself: 1) The inner and outer rings of the bearing are too tightly cooperated. 2) There are problems with the shape and position tolerance of parts, such as the coaxiality of parts such as machine base, end cover, shaft and other parts is not good. 3) Improper selection of bearings. 4) The bearing is not smooth or the bearing is not clean, and there are impurities in the smooth grease. ...

The cause of bearing noise in different situations of frequency converters - Reynolds The cause of bearing noise in different situations of frequency converters - Reynolds

1. If the bearing is in good continuous rotation condition, it will emit a low whining or humming sound. Sharp hissing, squeaking and other irregular sounds often indicate that the bearing is in a bad continuous rotation condition. The sharp squeaky noise can be due to the formation of an inappropriately smooth ...

The difference between heavy-duty inverter and light-duty inverter The difference between heavy-duty inverter and light-duty inverter

1. The starting time is different: light load generally refers to the small inertia of the equipment load, and the energy storage balance time of the demand for start-up is short, that is, the starting time is short. Heavy load generally refers to the long time of energy storage balance when the equipment load inertia is large and needs to be turned on, that is, the time of start-up. 2. The requirements for working current are not ...

The main failure mode of mechanical parts – Reynolds The main failure mode of mechanical parts – Reynolds

The top failure modes of mechanical parts: Failure: The mechanical part cannot complete its normal function within the planning and booking period and under the regular conditions. Ways in which mechanical parts fail: overall cracking, plastic deformation, corrosion, abrasion, gluing, and touch exhaustion General ...

The inverter cannot adjust the frequency solution - Reynolds The inverter cannot adjust the frequency solution - Reynolds

1. The acceleration moment is too short. Theoretically, the longer the acceleration time, the stronger the load lifting capacity. If the acceleration time is set too short, some VFDs will show an overcurrent or overload, overtemperature alarm, while others will not, and will only be stuck in a certain frequency band. 2.The V/F ratio is too large Some of this ...

Characteristics and Discrimination of Resistance Damage - Reynolds Characteristics and Discrimination of Resistance Damage - Reynolds

I often see many beginners tossing on the resistor when overhauling the circuit, and it is dismantling and welding, in fact, it is repaired a lot, as long as you understand the damage characteristics of the resistor, you don't have to bother. Resistors are the most numerous in electrical equipment ...

The difference between inverter motor and ordinary motor - Reynolds The difference between inverter motor and ordinary motor - Reynolds

1. The heat dissipation system is different: Generally, the cooling fan in the fan is in the same line as the fan movement, while the two are separated in the inverter motor. Therefore, when the frequency conversion of the fan is too low, it may burn out due to overheating. 2. Frequency conversion ...

Reynolds soft starter fault code and fault handling Reynolds soft starter fault code and fault handling

Reynolds soft starter fault code Instantaneous stop -F 01 Instantaneous stop terminal 7 to terminal 10 open TOO LONG STARTING TIME -F 02 STARTING TIME IS TOO LOW AND THE STARTING TIME IS TOO LONG (GREATER THAN 60S) Overheating -F 03 Start too often, reduce the number of starts Input out of phase -F 04 ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top