The difference between inverter motor and ordinary motor - Reynolds

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

1. The heat dissipation system is different: Generally, the cooling fan in the fan is in the same line as the fan movement, while the two are separated in the inverter motor. Therefore, when the frequency conversion of the fan is too low, it may burn out due to overheating.

                                 The difference between inverter motor and ordinary motor - Reynolds

2. The inverter motor is higher than the general motor because it has to accept the high-frequency magnetic field, so the insulation level is higher than that of the general motor, in principle, the general motor can not be driven by the inverter, but in order to save money in practice, the general motor is used to replace the inverter motor in many occasions that need speed regulation, but the speed regulation accuracy of the general motor is not high, and it is often done in the energy-saving transformation of fans and pumps. When replacing the inverter motor with a general motor, the carrier frequency of the inverter should be as low as possible to reduce the insulation damage to the motor by high frequencies. The inverter motor strengthens the slot insulation, one is the insulation material is strengthened, and the other is to increase the thickness of the slot insulation to improve the level of receiving high-frequency voltage.

3. The electromagnetic load is increased. Generally, the motor operation point is basically at the inflection point of magnetic fullness, if it is used as a frequency conversion, it is easy to be full, and a higher excitation current occurs, and the frequency conversion motor increases the electromagnetic load when designing, so that the magnetic circuit is not easy to be full. In addition, frequency conversion motors are generally divided into constant torque special motors, special motors with speed measurement devices and intermediate frequency motors with feedback vector control.

More on that
Inverter maintenance and undervoltage fault handling - Reynolds Inverter maintenance and undervoltage fault handling - Reynolds

In the repair of the inverter, we often hear about overpressure problems, but underpressure problems are also common problems encountered in the use of inverters. The reason is that the main circuit voltage is lower than the lower limit caused by the maintenance action or the damage of a rectifier bridge or the instantaneous power failure of the power grid, and the input is flat. Inverter after-sales ...

Reynolds inverter overhaul process Reynolds inverter overhaul process

1) Query and query fault phenomena. The fault phenomenon of the inverter is varied, for example, the same type of problem may have different problem phenomena, and different types of problems may have the same kind of problem, which brings difficulties to find the problem. However, the problem phenomenon is the fundamental basis for repairing the inverter ...

Servo drive failure and solution Servo drive failure and solution

1. When the servo motor of the robot is running at a very low speed, it is fast and slow, just like a creeping machine. Low-speed prostrate servo motors are usually caused by low system gain. Please adjust the parameter N.10.N.11.N.12 to adjust the system gain appropriately, or the automatic gain adjustment function of the running driver ...

Frequency conversion cabinet external conduit wiring method - Reynolds Frequency conversion cabinet external conduit wiring method - Reynolds

When it is required to wiring outside the frequency conversion cabinet, it is generally necessary to use the conduit for wiring, which requires suitable mechanical pressure and unsuitable mechanical damage, moisture-proof and corrosion-resistant. Conduits include the following two wiring methods: 1. Kim ...

Reynolds drive control panel description Reynolds drive control panel description

1. FUN button; Press the FUN button to enter the settings menu F00; 2. Press and hold the up button or down button to scroll to the code that needs to be set; 3. Press the FUN button to confirm at this moment, and adjust the entry parameters to the required value; 4、 ...

Renault is available in a variety of product ranges Renault is available in a variety of product ranges

JJR1000系列:   JJR1011;JJR1017;JJR1022;JJR1030;JJR1037;JJR1045;JJR1055;JJR1075;JJR1090;JJR1115;JJR1132;JJR1160;JJR1200;JJR1250;JJR1320;JJR1400;JJR1500;JJR1600 ...

Inverter leakage solution - Reynolds Inverter leakage solution - Reynolds

1. The cause of the leakage problem Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reasons for this shortcoming are theoretically expounded and stated as follows. Depend on...

Inverter power and box structure selection - Reynolds Inverter power and box structure selection - Reynolds

First, the selection of inverter power The system power is equal to the product of the inverter power and the motor power, and the system power is higher only when both are operating at a higher power. From the perspective of power, when selecting the power of the inverter, we should pay attention to the following points: 1) ...

Water pump inverter pressure adjustment method - Reynolds Water pump inverter pressure adjustment method - Reynolds

Water pump inverter pressure conditioning steps: 1. Open PID closed-loop control; 2. Close the pressure circuit; 3. Set the pressure feedback and set the given pressure; When the pump speed is changed, the outlet pressure can be changed. Adjust the operating frequency of the VFD. The higher the frequency, the higher the pump speed and the higher the pressure. About ...

How to measure a frequency converter with a multimeter – Reynolds How to measure a frequency converter with a multimeter – Reynolds

How to use a multimeter to measure the quality of the inverter, it needs to be noted that for personal safety, it is necessary to ensure that the machine is powered off, and remove the inverter input power line R, S, T and output line U, V, W before operation! First of all, the multimeter is hit to the "secondary pipe" file, and then through the multimeter ...

The difference between servo and inverter - Reynolds The difference between servo and inverter - Reynolds

Overload can be different Servo drives generally have 3 times the overload ability, which can be used to overcome the inertial moment of the inertial load at the moment of start-up, while the frequency converter generally allows 1.5 times the overload. Handling precision Servo control ...

The structure of the low-voltage circuit breaker - Reynolds The structure of the low-voltage circuit breaker - Reynolds

Low-voltage air circuit breaker, also known as active air switch or air switch, belongs to the switch electrical appliance, is used when the circuit is overloaded, short circuit and undervoltage can actively break the circuit of the electrical appliances, can also be used as infrequent start of the motor or opening and closing circuit, low-voltage air circuit breaker has an all-round circuit breaker ...

Common faults and solutions of vector inverter - Reynolds Common faults and solutions of vector inverter - Reynolds

The following faults may be encountered during the use of the inverter, please refer to the following methods for simple fault analysis: 1. No manifestation at power-on: 1) Use a multimeter to check whether the input power supply of the inverter is consistent with the rated voltage of the inverter, and check the cleaning problem. 2) ...

Key points for the selection of Reynolds servo motors Key points for the selection of Reynolds servo motors

Each type of servo motor has additional torque, maximum torque and servo motor inertia and other parameters in the standard items, each parameter and load torque and load inertia must have a relevant connection, the output torque of the servo motor should meet the requirements of the movement conditions of the load organization, such as the speed of the acceleration ...

"RNB6000 frequency conversion governor" was included in the National Torch Program "RNB6000 frequency conversion governor" was included in the National Torch Program

Recently, in the "2012 National Torch Program Project" issued by the Ministry of Science and Technology of the People's Republic of China, the "RNB6000 Frequency Conversion Governor" independently developed by Reynolds was included in the "2012 National Torch Program Project" with its domestic leading skills and efficient energy-saving conversion power.

AC servo motor with inverter control method - Reynolds AC servo motor with inverter control method - Reynolds

Because the inverter and servo are different in performance and function, and the use is not very different, it is not possible: 1) In the case of speed control and torque control, the general frequency converter is not very high, and there are also frequency converters that are used to react signals in the upper position to form a closed loop.

Lightning protection measures for Reynolds frequency converters Lightning protection measures for Reynolds frequency converters

The lightning protection measures of the inverter equipment are another important peripheral measure to ensure the safe operation of the inverter, especially in the area where lightning is active or in the lively season, this problem is particularly important. Today's inverter products are generally equipped with mines.

DCS and PLC and other control cabinets are inspected before leaving the factory DCS and PLC and other control cabinets are inspected before leaving the factory

1. Test preparation: 1. It is necessary to remove all power switches before powering on the PLC control cabinet or IO cabinet. 2. It is necessary to completely cut off the connection between the PLC or DCS card and the outside. All front adapters are to be loosened and raised. 3. Check the power terminal wires and connectors.

The main failure mode of mechanical parts – Reynolds The main failure mode of mechanical parts – Reynolds

The top failure modes of mechanical parts: Failure: The mechanical part cannot complete its normal function within the planning and booking period and under the regular conditions. Ways in which mechanical parts fail: overall cracking, plastic deformation, corrosion, abrasion, gluing, and touch exhaustion General ...

Inverter power modification method - Reynolds Inverter power modification method - Reynolds

1. Yaskawa inverter G5-G7 power correction: enter the menu and then return to 02-04 after A01=4 is the power data, and the factory voltage of rehabilitation has also changed after the change. 2. Sanken inverter IHF-IPF-SHF series: enter the CD900 parameter and enter 365 to confirm (change 2 times...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top