Xinjie inverter maintenance method

Create Date: 2024-8-30 12:03:23|Source: XINJE

In the instruction manual of the inverter, there is a column that discusses in detail the fault code display of the inverter.
Xinjie inverter maintenance method
  1. Short-circuit maintenanceIf there is short-circuit maintenance on the side of the inverter's operation, "0" means that the inverter has short-circuit elements inside or outside. There are several reasons for this:

(1) In this case, if the load is thrown off, the inverter and the load are disconnected, and the inverter is opened empty, and the inverter should work normally. At this time, we use a megohmmeter (or a shake meter) to measure the motor insulation, the motor winding will be short-circuited to the ground, or the insulation of the motor wire and terminal board will deteriorate, and the motor and auxiliary equipment should be checked at this moment.

(2) Internal problems of the inverterIf there is no problem with the load after the above detection, and the inverter is still short-circuited and maintained when it is empty, this is an internal problem of the inverter and should be swept away. On the side of the module of the inverter bridge, if a certain junction of the IGBT breaks down, it will form a short circuit maintenance, which can cause the bridge arm to break down, or even fail to power it, and the front circuit breaker will trip. In this case, it is generally only allowed to send electricity again to prevent the expansion of the fault and the formation of a greater loss, and the manufacturer should be contacted for repair.

(3) There is a problem with the internal disturbance or detection circuit of the inverter, and the internal disturbance of some machines is also easy to form such problems, and the inverter is not too big a problem at this moment, only uninterrupted and irregular short-circuit maintenance, that is, the so-called mismaintenance, which is the formation of disturbance. The short-circuit maintenance of the inverter is generally shunted and sampled from the positive and negative buses of the main circuit, and the current sensor is transmitted to the main control chip for maintenance through the detection of the main control board.  Regarding the problem of disturbance, the current low-voltage and high-power and medium and high-voltage inverters are equipped with photoelectric isolation, but there are also disturbances, mainly because the control line of the current sensor is unreasonable, and the line can be routed alone, away from the power line, strong voltage, high current line and other lines with strong electromagnetic radiation, or choose shielded wires to enhance the ability to resist disturbance and prevent mismaintenance.

More on that
Explanation of some common fields of inverter - Xinjie inverter Explanation of some common fields of inverter - Xinjie inverter

1. The inverter is used in the air conditioning load class Office buildings, shopping malls and some supermarkets and factories have central air conditioning, and the electricity consumption of air conditioning is very large at the peak of electricity consumption in summer. In the hot climate, Beijing, Shanghai, Shenzhen air conditioning ...

Xinjie plc programming software XCPPro Xinjie plc programming software XCPPro

XCPPro is a professional XCPPl programming software, which is a new XC series PLC programming software, which can be used normally by making corresponding configurations in XCPPro. The software supports WindowsXP32-bit Win764-bit system. ...

A brief introduction to some XD series PLCs of Xinjie A brief introduction to some XD series PLCs of Xinjie

XDM Series Sport Control (Control Points: 24/32/48/60) Support basic motion control instructions, can realize two-axis linkage, interpolation, follow-up and other functions, can achieve 4-axis independent pulse output, up to 10-axis pulse output, together to support almost all of the standard PLC...

Introduction to PLC debugging steps - Xinjie Introduction to PLC debugging steps - Xinjie

Input and output loop debugging 1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply mode (internal power supply or external power supply) is consistent with the field instrument; Use a signal generator to add a signal to each channel at the field end, generally taking 0, 5 ...

Xinjie six-station stator internal winding system solution Xinjie six-station stator internal winding system solution

As one of the important equipment for manufacturing motors, the six-station high-speed inner winding machine is widely used in electric fans, range hoods, purifiers, automobiles and other occupations. Now there are single station, double station, four station and six station winding machine types, and the six-station inner winding machine launched by Xinjie can reach up to 1200 times/i ...

The difference between motion controller and PLC - Xinjie The difference between motion controller and PLC - Xinjie

The motion control mainly touches the control of stepper motors and servo motors, and the control structure mode is generally: control equipment + driver + (stepper or servo) motor. The control equipment can be a PLC system, or a special automation device.

The way the PLC controller works - Xinjie The way the PLC controller works - Xinjie

Although many relays, timers and counters are often used in the ladder diagram programs used by PLCs, PLC does not have these hardware physically, but uses memory and program programming methods to do logic control and editing, and connects external mechanical devices to make physical devices through output components.

Causes and solutions of inverter leakage - Xinjie Causes and solutions of inverter leakage - Xinjie

1. The cause of the leakage problem Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reason for this problem is explained and stated as follows. Depend on...

VFD Configure Braking Resistor step VFD Configure Braking Resistor step

Confirm the rated power and resistance value of the braking resistor. The rated power of the braking resistor should be determined according to the power and moment of inertia of the motor, and the resistance value should be selected according to the specifications of the VFD. In the VFD's parameter settings, find the parameters related to the braking resistor, such as the braking resistor selection ...

Xinjie launched a professional solution for tapping machines Xinjie launched a professional solution for tapping machines

Tapping machine is a kind of machine tool that uses taps to process internal threads, and it is the most widely used internal thread processing machine tool. The tapping machine avoids the limitations of lathes, drilling machines or manual tapping, and saves time, labor, is not easy to rot teeth, and taps are not easy to break.

Internal interference in PLC remote module system - Xinjie Internal interference in PLC remote module system - Xinjie

The internal disturbances of the PLC system are mainly caused by the mutual electromagnetic radiation between the internal components and circuits of the system, such as the mutual radiation of logic circuits and their influence on the imitation circuit, the interaction between imitation and logic, and the mutual mismatch between components. How to deal with PLC long distances ...

The application field of PLC - Xinjie The application field of PLC - Xinjie

At present, PLC has been widely used in various industries such as steel, petroleum, chemical industry, electric power, building materials, machinery manufacturing, cars, textile, transportation, environmental protection and culture and entertainment at home and abroad. 1 ...

XDH | XLH series of 16-axis high-performance EtherCAT controllers XDH | XLH series of 16-axis high-performance EtherCAT controllers

The XDHI XLH series of 16-axis high-performance EtherCAT controllers is the perfect choice for small motion control. Product model XDH-30A16-E/XDH-30A16L-E Small/16-axis type Frequency: 600MHz Program Capacity: ...

Troubleshooting methods for unsuccessful touch screen penetration Troubleshooting methods for unsuccessful touch screen penetration

A:a. Now only the TGM series touchscreen supports penetration as well as network connectivity b. At present, the penetration function only supports the PLC class of Xinjie that supports the Xnet protocol, and other models do not support it temporarily c. Check whether the computer has the latest version of config installed serial port equipment tool (soft ...

The main functions of the Xinjie touch screen and PLC control system The main functions of the Xinjie touch screen and PLC control system

(1) The entire control process works under the Chinese system, and the handling is completely Chinese (2) Realize the active control of batching, blanking, mixing and concrete displacement (3) The mixing time and blanking sequence can be adjusted immediately (4) Batching, blanking, mixing ...

Precautions for installation of Xinjie servo motor Precautions for installation of Xinjie servo motor

The MS series of servo motors can be installed in either the horizontal or vertical direction. However, if it is installed incorrectly, or in an unsuitable place, it can shorten the life of the motor or cause unexpected accidents.   Storage temperature In the unpowered state ...

PLC control back troubleshooting method - Xinjie PLC control back troubleshooting method - Xinjie

1. PLC input and output A small PLC controls a complex system with agility, and what can be seen is the upper and lower rows of staggered input and output relay terminals, corresponding lamps and PLC numbers, just like a piece of integrated electricity without dozens of feet. If any ego doesn't look at reason...

Thermal Relay Current Tuning - Xinjie Thermal Relay Current Tuning - Xinjie

(1) What is the current setting value of the thermal relay? The setting current of the thermal relay refers to its action current, that is to say, it is adjusted between 0.95 - 1.05 times of the rated current of the motor being maintained.

Introduction of XC series of Xinjie PLC products Introduction of XC series of Xinjie PLC products

The XC series includes XC1 (Economy), XC2 (Basic), XC3 (Standard), XC5 (Enhanced), XCM (Sport), XCC (High Performance) and their corresponding expansion modules. XC series PLC can be ...

The difference between the models of Xinjie TG series touch screen The difference between the models of Xinjie TG series touch screen

The suffix is XT and only supports RS232 communication, 4 inches out. The suffix MT supports RS 232/485/422 communication. The suffix is UT on the basis of MT, and a U disk port is added, which can be used to import and export engineering and CSV data from U disk. The suffix is named ET and is added to the UT ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top