1、CPU。 The CPU of the plc is actually the central processing unit, which can carry out the operation and processing of various data, convert various input signals into input registers, and then carry out logical operation, timing, counting, arithmetic operation, data processing and transmission, communication networking and various operations, compile and execute commands for the prepared program, and transmit the results to the output end to echo various external devices.
2. Memory. The memory in the PLC system is mainly used to store system programs, user programs, and job status data. The memory of a PLC includes system program memory and user memory.
3. Input/output interface (I/O) of switching quantity. The input and output interfaces of switching quantities are the interfaces connected to the control appliances in the industrial production field. The input and output interfaces of the switching quantity adopt optical resistance isolation and RC filtering, which realizes the electrical barrier between the internal circuit and the external circuit of the PLC and reduces the electromagnetic disturbance, and meets the matching needs of various signals in the industrial field.
4. a power module. The power module of the PLC can process the external input power supply and convert it into the DC power supply required for the internal circuit operation of the PLC, such as the CPU, memory, and input and output interfaces.
|
More on that
|
The four main functions of the PLC control cabinet - Xinjie
1. Power switching and maintenance: There is a circuit breaker in the PLC cabinet, which is connected to the incoming power supply. In addition to making and disconnecting circuits, circuits can also be maintained for short circuits and overloads. Cut off the power supply during repairs.
2. Start and stop control function: The panel of the PLC inverter cabinet is equipped with a man-machine interface, and the inverter start and stop button ...
|
|
Interference within the PLC remote module system - Xinjie PLC
The internal disturbance of the PLC system is mainly caused by the mutual electromagnetic radiation between the components and circuits inside the system, such as the mutual radiation of logic circuits and their influence on the imitation circuit, the interaction between the imitation ground and the logical ground and the mutual mismatch between components. How to deal with PLC long distances effectively ...
|
|
What protocols does the PLC wireless transmission module support?
1. Japanese PLC special wireless communication terminal
DTD435M embedded RS232/RS485 dual interfaces, adaptive Mitsubishi N:N: protocol, Omron HOST Link protocol, Delta and Yonghong and other Modbus RTU protocols. No programming, no secondary development, can directly replace RS232/RS48 ...
|
|
The application field of PLC - Xinjie
At present, PLC has been widely used in various industries such as steel, petroleum, chemical industry, electric power, building materials, machinery manufacturing, cars, textile, transportation, environmental protection and culture and entertainment at home and abroad.
1 ...
|
|
New models such as IoT industrial controllers and smart cameras have been launched
From 14:00 to 15:20 on May 14 last year, the X-SIGHT visual brand conference with the theme of "Vision, Light Up Intelligent Manufacturing" was held online, officially announcing that Wuxi Xinjie and Intel will join hands to create a new era of intelligent manufacturing. X-SIGHT unveiled a new Intel chip-based ...
|
|
Xinjie developed professional solutions for sealing lines
Introduction to the glass sealing industry
As a relatively old industry, the vitality of the glass industry has further burst out in the modern society, due to the social development and the improvement of people's aesthetics, the demand for glass in all walks of life is also increasing, which is also more abundant.
|
|
The difference between the models of Xinjie TG series touch screen
The suffix is XT and only supports RS232 communication, 4 inches out.
The suffix MT supports RS 232/485/422 communication.
The suffix is UT on the basis of MT, and a U disk port is added, which can be used to import and export engineering and CSV data from U disk.
The suffix is named ET and is added to the UT ...
|
|
Xinjie PLC failure and solution
Xinjie PLC conditions are established, why is the corresponding coil not in place? There are two possible reasons for this:
(1) The same coil may be used in multiple places to perform the double coil output, and when the double coil is output, the coil on the rear side will operate first.
(2) ...
|
|
Introduction of PLC explosion-proof control cabinet
1. The use field of PLC explosion-proof control cabinet: PLC explosion-proof control cabinet inverter explosion-proof control cabinet
PLC explosion-proof control cabinet is generally used in Zone 1 and Zone 2; Class IIA, IIB, IIC, Baozha gases with temperature groups from T1 to T4; Suitable for combustible dust applications; Indoor, outdoor ...
|
|
The range of use of universal frequency converters
A universal inverter is an electronic device used to control the speed of an electric motor, which can change the speed of the motor as needed, and then achieve higher production efficiency and power savings. The universal inverter has a wide range of application scales and can be used in various types of motors, including communication motors, direct motors, ...
|
|
The main functions of the Xinjie touch screen and PLC control system
(1) The entire control process works under the Chinese system, and the handling is completely Chinese
(2) Realize the active control of batching, blanking, mixing and concrete displacement
(3) The mixing time and blanking sequence can be adjusted immediately
(4) Batching, blanking, mixing ...
|
|
Inverter protection and display function - Xinjie
1. Maintenance of the inverter itself:
Instantaneous overcurrent, overvoltage, undervoltage, overload, short circuit to ground, abnormal control circuit, then for the maintenance of the inverter itself, the overcurrent, overvoltage, undervoltage and so on set the limit value, when the inverter is running, if ...
|
|
Introduction of Xinjie MS6G-130 series inertia servo motor
For the 130 frame same service motor, the MS6H-130 series high inertia servo motor previously launched by Xinjie is mainly used in large inertia load occasions, in order to enrich the application scenario, the MS6G-130 series medium inertia servo motor is launched, which is suitable for DS5 series servo drive
...
|
|
Xinjie released MS6 series B3 motors
Since the advent of the MS6 series B1 and B2 servo motors, they have been widely recognized by customers for their outstanding performance advantages, and their performance in terms of temperature rise, overload ability, overspeed range and protection level is far better than that of MS5 series servo motors.
This MS6 series B3 motor released will ...
|
|
PLC installation precautions - Xinjie
Of course, PLC control is much more reliable than relay control, but if the device does not meet the requirements, it will not work. Therefore, the PLC machine should be installed correctly outside.
(1) Pay attention to the environment of the installation
The temperature should not be lower than 0°C and above 55°C, for example, not installed by a large stove, and ...
|
|
XDH | XLH series of 16-axis high-performance EtherCAT controllers
The XDHI XLH series of 16-axis high-performance EtherCAT controllers is the perfect choice for small motion control.
Product model
XDH-30A16-E/XDH-30A16L-E Small/16-axis type
Frequency: 600MHz
Program Capacity: ...
|
|
Thermal Relay Current Tuning - Xinjie
(1) What is the current setting value of the thermal relay?
The setting current of the thermal relay refers to its action current, that is to say, it is adjusted between 0.95 - 1.05 times of the rated current of the motor being maintained.
|
|
The solution to the overcurrent of the inverter - Xinjie
1. On the premise of satisfying the production equipment and process requirements, the acceleration or deceleration time should be increased as much as possible, and then the overcurrent generation in the process of acceleration or deceleration can be avoided.
2. Check whether the inverter, motor, and production equipment are well matched, whether the transmission part is sensitive, and whether the material is ...
|
|
Inverter technology strategy in electromechanical control
In the process of century industry, the more top-level software and hardware planning for the suspension of frequency conversion skills, first according to the characteristics of traditional air compressor motors, comprehensively analyze the causes of energy consumption and operation characteristics, so as to plan the control of frequency conversion skills speed regulation, air skill tightening, pressure sensing skills improvement, etc.
|
|
Common faults of wires and cables - Xinjie
The most direct cause of cable problems is the breakdown due to the loss of insulation. First of all, there are:
a. Overload operation. Long-term overload operation will increase the temperature of the cable, aging the insulation, resulting in breakdown of insulation and degradation of construction quality.
b. Electrical: the construction process of the cable head does not meet the requirements.
|
|