Air conditioner shows H1 fault code solution – Rittal

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

1. The air conditioner displays the H1 fault code - the reason

When the outdoor temperature is low and the humidity is high, the heat exchanger of the outdoor unit will be frosted after the air conditioner runs for a period of time, then the automatic defrost function will be activated, and the heating operation will be temporarily stopped for 5-10 minutes. Air conditioning heating and defrosting shows H1 This is a normal phenomenon, because the air conditioner heats up, the outside unit becomes cool, when the heat reaches a certain temperature, the condenser of the outside unit will be defrosted, at this time, the internal fan is stopped, the external fan is shut down, the compressor works, the four-way valve is reversed, and the external machine is heated after the reversal to melt the frost of the external machine, so the internal machine becomes refrigeration, but it will not blow the wind, and the heating will return to normal after the end of the external machine defrosting (3-5 minutes), please don't worry.

2. The air conditioner displays an H1 fault code - indicating that defrost is needed

First of all, we have to figure out what the H1 fault code means, what is the fault of the air conditioner H1, at this time, it means that the air conditioner is defrosting, and now basically every air conditioner has such a defrosting function. During the automatic defrost process, both the indoor and outdoor units of the fans are stopped, and steam may be emitted from the outdoor units during the defrosting process. This is caused by rapid defrosting, not a malfunction, and heating operation is resumed after defrosting.

3. The air conditioner displays the H1 fault code - the solution

The new defrosting function of the air conditioner is to press the mode key and the auxiliary heat key at the same time when the remote control is turned off, and H1 will be displayed, at this time, the remote control air conditioner has the new defrosting function, that is, after the remote control is turned off during defrosting, the air conditioner will continue to defrost, and it will not automatically shut down until the end to avoid defrosting the next time it is turned on.
Air conditioner shows H1 fault code solution – Rittal

More on that
Rittal cables – what are the types of industrial wires and cables commonly used? Rittal cables – what are the types of industrial wires and cables commonly used?

Industrial wires and cables include single-core wires and cables, rubber cables, shielded control cables, flame-retardant cables, fire-resistant cables, etc. Single-core wire and cable It means that there is only one conductor in the insulation layer, the common BV wire, and B represents the wiring; V stands for insulating polyvinyl chloride. Suitable for AC ...

Rittal enclosures – what are the functions of the enclosure? Rittal enclosures – what are the functions of the enclosure?

The function of the cabinet is security Packing mission-critical IT equipment into lockable cabinets makes it easier for network administrators to limit the number of people who can flip out the cabinets. The function of the cabinet is heat dissipation Estimate how much heat your device is ...

Rittal & Lithium Battery The industrial transformation of the trillion-dollar new energy vehicle market Rittal & Lithium Battery The industrial transformation of the trillion-dollar new energy vehicle market

The power of the 10 billion market   With the help of continuous favorable policies, China's new energy vehicles have maintained rapid growth this year. According to data from the China Association of Automobile Manufacturers, the production and sales of new energy vehicles reached a new high in October, with a year-on-year increase of 87.6% and 81.7% to 762,000 and 714,000 units, respectively.

How to set the temperature of the Rittal cabinet air conditioner SK 3332540 How to set the temperature of the Rittal cabinet air conditioner SK 3332540

1. Press and hold the H4 button for 5 seconds to enter programming mode and ST will be displayed on the screen. 2. Click the H4 button to display 35 on the screen, then click the H2 button to display Cod on the screen, and then click the H2 button continuously to display from 0 to 22 on the screen. 3. Click H2/H3 and press ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is the role of a DC system in a substation? Answer: The DC system provides reliable DC power supply for control signals, relay protection, automatic devices and accident lighting in the substation, and also provides reliable operating power for operation. The reliability of the DC system has a significant impact on the ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the precautions for using current transformers? Answer: 1. The secondary side shall not be open when working; 2. One end of the secondary side must be grounded; 3. The polarity of the terminal should be paid attention to when connecting. What are the precautions for using voltage transformers? A:1. When working, its secondary side shall not be short-circuited ...

Rittal's edge data centres inject new momentum into the digital development of enterprises Rittal's edge data centres inject new momentum into the digital development of enterprises

At the China International Information and Communication Exhibition (PT Exhibition) in Beijing, Rittal is showcasing its innovative "edge data center" solutions. In an era of increasing demand for high-speed processing and maximum flexibility, small, flexible edge data centers are digitizing enterprises in a steady stream of ...

Rittal Blue e+ cooling unit in the cooling of the Airbus A320 test plant Rittal Blue e+ cooling unit in the cooling of the Airbus A320 test plant

A new A320 Airbus aircraft must pass rigorous testing before it can be put into service, so to ensure a smooth flight, not only the aircraft itself needs to be protected from overheating, but also the test hardware needs to be properly protected. Airbus uses Rittal Blue e+ cooling units to make it ...

Rittal cabinets – heat dissipation and dust protection for electrical cabinets Rittal cabinets – heat dissipation and dust protection for electrical cabinets

1. Built-in air conditioner for heat dissipation The cabinet is equipped with a refrigeration system, the evaporator and power devices are installed inside the cabinet in a closed manner, and the condenser and compressor are placed in the external circulation air duct or outside the cabinet. Since the power unit is sealed in the cabinet, as long as the appropriate sealant is used ...

Rittal and Epan – the intelligent future of drive cabinet systems Rittal and Epan – the intelligent future of drive cabinet systems

"Promote the deep integration of the Internet, big data, and artificial intelligence with the real economy, and make the digital economy bigger and stronger." The new generation of information technology is accelerating the all-round and in-depth integration with the traditional manufacturing industry. Rittal and Epan, with "digital twins" from virtual to real, help control cabinets and open ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

How is an electric current formed? Answer: The free electrons in the conductor move regularly and directionally under the action of the electric field force, and an electric current is formed. What are the indicators of power quality? Answer: Voltage deviation, voltage fluctuation and flicker, voltage sine wave distortion rate, frequency deviation. ...

Rittal cables – the main use of power cables Rittal cables – the main use of power cables

Power system: The wire and cable products used in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables (basically replaced by plastic power cables), rubber cables, overhead insulated cables), branch cables, magnet wires and power equipment...

Rittal cabinets – the cause of moisture in electrical cabinets Rittal cabinets – the cause of moisture in electrical cabinets

(1) The cause of moisture in the cabinet 1) Environment shutdown. The ring main unit or the opening and closing station itself is a closed environment, because of the poor ventilation conditions, it is easy to gather moisture and generate condensation, and there are many large buildings today in order to reduce the occupied area, the opening and closing station, the power distribution room is built in the basement. Cause...

Rittal enclosures – considerations for control cabinet transfers Rittal enclosures – considerations for control cabinet transfers

First, the assembly process The assembly process is the guarantee of the assembly work, because only the assembly according to the process can ensure the quality of the assembly work. The process is the standard and requirement of assembly, and only the assembly according to the process can ensure the safety of assembly. However, before the assembly, the technical ...

Introduction to the process characteristics of the Rittal cabinet - PS frame universal control cabinet Introduction to the process characteristics of the Rittal cabinet - PS frame universal control cabinet

1. The cabinet door is 25mm from the ground and 2.5mm thick mounting plate, and there are 20mm wide U-shaped curved edges on both sides, which makes the mounting plate stronger and easy to handle. 2. The three cable introduction cover plates at the bottom of the box can be replaced with each other, which is easy to move, easy to import cables, and easy to open holes into the line. 3 ...

What are the advantages of Rittal enclosure processing – sheet metal cabinets? What are the advantages of Rittal enclosure processing – sheet metal cabinets?

The development of sheet metal cabinet and chassis processing industry is getting bigger and bigger, which is due to the rapid development of society, the popularity of high-tech products, server cabinets, computer main chassis, equipment shells, etc. What are the advantages of sheet metal cabinet enclosures? 1. Cabinet and chassis products provide space for ...

Rittal and the Fraunhofer Institute in Germany explain the implementation of the digital twin Rittal and the Fraunhofer Institute in Germany explain the implementation of the digital twin

How to promote the further development of smart factories and smart production? The Rittal Hager plant in Germany illustrates how the smart factory can be accelerated with a digital twin in manufacturing!   As one of the world's modern cabinet production bases, the Hager plant has a production capacity of 24,000 square meters.

Five hidden details you didn't know about Rittal cabinets and common Q&A Five hidden details you didn't know about Rittal cabinets and common Q&A

Five details that are easy to overlook: One of the hidden details: steel The most basic thing of a cabinet is to look at the steel, the Rittal standard cabinet is made of section steel, there are many masters who understand the cabinet to understand, the steel plate must be thick, just knock it with your fingers. General ...

For the first time, the Rittal Rittal and Circle B and Switch data centres have launched the European OCP Experience Centre For the first time, the Rittal Rittal and Circle B and Switch data centres have launched the European OCP Experience Centre

Circle B, Rittal and Switch data centres in Germany launch the first European Open Computing Project (OCP) Experience Centre. The full-featured OCP environment is located at one of the facilities of three switching data centers in the Amsterdam area. (The OCP Experience Center can be used as a demo center, but it is also ...

Rittal supports the "smart" and "low-carbon" development of new infrastructure Rittal supports the "smart" and "low-carbon" development of new infrastructure

In recent years, with the accelerated development of China's informatization process and the continuous expansion of its scale, the demand for digital centers, as the carrier of the digital economy, is also increasing day by day. The operation of the digital center needs the support of a stable and energy-saving power system.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top