Five hidden details you didn't know about Rittal cabinets and common Q&A

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

Five details that are easy to overlook:

One of the hidden details: steel

The most basic thing of a cabinet is to look at the steel, the Rittal standard cabinet is made of section steel, there are many masters who understand the cabinet to understand, the steel plate must be thick, just knock it with your fingers. In order to save costs, domestic cabinets are generally made in terms of thickness, while the thickness of Rittal's steel, ordinary side panels or back panels is as high as 1.5-2mm, and the galvanized mounting plate has reached a thickness of 3mm, which is far more than many competitors. Only with enough steel will the life and mechanical resistance of the cabinet be greatly enhanced.

Hidden detail number two: spray paint

Painting is a problem that is easy to ignore, most of the cabinet's painting is very similar in appearance, in fact, there are essential differences between the paintings, and most of the cases of spray paint, only after a period of use, such as paint peeling. Most domestic cabinets are sprayed, resulting in uneven paint, and are affected by the on-site environment, which is prone to quality problems. The Rittal cabinet uses the same electrophoretic paint as the car to ensure that the outer paint is uniform and not easy to fall off, which can give the Rittal cabinet a great advantage in rust and dust prevention. And the electrophoretic paint is particularly outstanding in anti-fingerprint.

Hidden detail 3: Complete certification

Many people may scoff at certification and think it is useless, but behind the certification is a myriad of tests and standards. The certification of Rittal cabinets is also not available to many cabinet manufacturers. Rittal's certifications, from United States UL to Russian Classification Society to European standards, guarantee the high quality of the Rittal enclosures and their ability to maintain an edge in a wide range of tender scenarios.

Hidden detail number four: modular design

In order to ensure quality, Rittal uses standard assembly lines. The problem with standard production lines is that it is difficult to meet the increasing requirements of non-standard and flexible production, so Rittal has carried out a modular design for the industrial market, and realizes non-standard functions through easy installation. For example, Rittal bases and side panels can be assembled at any length with the enclosure frames. The modular design can not only ensure that the product has the quality of standard products, but also meet the requirements of flexible production, which many similar competitors do not have.

Hidden detail number five: localization

Rittal cabinets are currently in China, most of the cabinets have domestic foundry factories, as early as many years ago, Rittal cabinets were localized, localized products are cheap, and can even reach the price of domestic cabinets with the support of certain needs. The local domestic Rittal cabinets are produced using Rittal's standards and technical patents, and the quality is quite good. Although the overall quality control and quality are slightly inferior to the cabinets imported from Germany, they can also outperform most domestic cabinets, and can enjoy the same after-sales and imported products, which is very suitable for customers considering the cost of procurement. At present, the main OEM product models in China are PS4000 cabinets and Compact air conditioners, which can meet the needs of most customers.
Five hidden details you didn't know about Rittal cabinets and common Q&A
  Frequently Asked Questions and Answers:

  1.

What accessories are included in a Rittal cabinet?

Answer: The cabinet consists of a frame, a top plate, a back plate, a mounting plate, a three-section base plate, an eye, a door, a standard lock and a key. Side panels and base are not included, and need to be equipped separately

  2.

What if you want a size or color that doesn't exist in your sample?

You can go through the non-standard customization process, but the delivery time and price will increase

  3.

What are the different levels of protection available for Rittal?

IP54 (economy), IP55, IP66

  4.

Do Rittal accessories come with mounting accessories?

All come with their own pack

  5.

How tall is the base of the Rittal?

There are two models: 10CM and 20CM

  6.

What are the precautions for opening holes?

Hole opening will increase the lead time and cost, and it is also necessary to provide a hole positioning map

Note: The articles and pictures and videos on this site are from the Internet, if there is any infringement, please contact this site to delete, this website will quickly respond to you and deal with it

More on that
How to set the temperature of the Rittal air conditioner How to set the temperature of the Rittal air conditioner

1. Set the target temperature: the default temperature of the original factory is 35°C, you can press and hold the set button for more than 1 second after starting, the parameters start to flash, complete the temperature adjustment by pressing the UP and DOWN buttons, and after adjusting to the target temperature, press the set button to store the set parameters. 2. High temperature alarm: ...

Presentation of the features of the Rittal cabinet TS8 seismic kit Presentation of the features of the Rittal cabinet TS8 seismic kit

Since ancient times, truss planning has been the way to create a stable and earthquake-tolerant mechanical structure. This plan consists of individual members connected at two ends, which form a triangle. The members are almost exclusively subjected to compressive or tensile forces, which makes the entire structure very strong.

Rittal enclosures – what should I consider when choosing a cabinet? Rittal enclosures – what should I consider when choosing a cabinet?

1. Reliable quality assurance Choosing the right server and cabling cabinet is important, and the slightest negligence can lead to huge losses. No matter which brand of product it is, quality is the first thing that users should consider. 2. Load-bearing guarantee With...

Rittal cabinets – judgment and handling of high-voltage switchgear closing faults Rittal cabinets – judgment and handling of high-voltage switchgear closing faults

Closing faults can be divided into electrical faults and mechanical faults. There are two types of closing methods: manual and electric. Failure to close manually is generally a mechanical failure. Manual can be closed, electric can not close is an electrical fault. 1. Protection action: The protection action has been analyzed in front to trip the switch. ...

The Rittal TS8 system solution is designed to cope with extreme mining conditions The Rittal TS8 system solution is designed to cope with extreme mining conditions

Energy consumption planning continues to grow, and countries around the world have significantly increased the supply of low-carbon power such as nuclear, hydro, wind, and solar energy in order to achieve energy conservation and emission reduction. But now that natural resources are simply being exploited, what are the important developments of green energy that are lacking? The answer is: geothermal energy ...

What are the moisture-proof measures for Rittal cabinets – electrical cabinets? What are the moisture-proof measures for Rittal cabinets – electrical cabinets?

1. Improve the environment inside and outside the cabinet 1. We not only need to keep the electrical cabinet dry and clean, but also need to do a good job of cleaning and sanitation in the distribution room where the distribution cabinet is placed to prevent water and dust from entering the cabinet 2. The lighting environment of the distribution cabinet should be good, and it should be equipped with professional cabinet lighting ...

Rittal cables – the meaning of the first letter in the number of the control cable Rittal cables – the meaning of the first letter in the number of the control cable

First of all, the number of the control cable often starts with the letter "C", which indicates that the control cable is specially designed to connect different sensors and control devices as a medium for signal transmission. This kind of cable can transmit data signals, and has a certain resistance to wear and chemical corrosion, so it is widely ...

How to choose a distribution box for home renovation - Rittal How to choose a distribution box for home renovation - Rittal

1. Determine the material of the distribution box First of all, from the material selection, the distribution box on the market is divided into plastic and metal two materials, metal material is durable, strong resistance, but it is easy to rust and corrode when encountering water stains; Although plastic is light and cheap, it is not very durable. Therefore the root ...

Rittal cables – common faults in power cables Rittal cables – common faults in power cables

Short-circuit fault: There are two-phase short circuits and three-phase short circuits, which are mostly caused by hidden dangers left in the manufacturing process. Grounding fault: one or more cores of the cable break down to the ground, and the insulation resistance is lower than 10kΩ is called low-resistance grounding, and higher than 10kΩ is called high-resistance grounding. Mainly due to cable corrosion, lead ...

What are the functions on the operation panel of the inverter control cabinet? What are the functions on the operation panel of the inverter control cabinet?

Display parameters: The control panel can display various parameters of the inverter, such as input/output voltage, current, frequency, speed, etc. Parameter setting: The control panel can set various parameters of the inverter, such as operating mode, frequency range, acceleration time, deceleration time, etc. ...

Rittal cabinet - judgment and treatment of high-voltage switchgear opening faults Rittal cabinet - judgment and treatment of high-voltage switchgear opening faults

Opening faults can also be divided into mechanical faults and electrical faults. Electrical faults mainly include open control loops, coil faults, auxiliary switch faults, etc. 1. Fault phenomenon: when the red light is not on, the electric cannot be opened, which is the fault of the auxiliary switch. When the opening coil burns out, there is smoke, odor, insurance ...

What do you need to pay attention to when grounding the electrical control cabinet? What do you need to pay attention to when grounding the electrical control cabinet?

1. Make sure that all equipment in the electrical control cabinet is well grounded, and use short and thick grounding wires to connect to the common grounding point or grounding busbar. Any control equipment connected to the inverter should be co-grounded with it, and likewise ground with short and thick wires; 2. Flat conductors are used, e.g. ...

Some precautions should be taken in the installation and setting of Rittal air conditioning Some precautions should be taken in the installation and setting of Rittal air conditioning

The arrangement of the electronics in the cabinet Note: Condensation is dangerous! When the electronics are arranged in a Rittal cabinet, the cold air from the air conditioner must not flow directly to the live device. Cold air must not be allowed to flow directly to a hot exhaust gas stream from a live device such as a frequency converter. Because this will lead to ...

Rittal won the Best Partner Award from Hengxin Software and Yokogawa Automation Rittal won the Best Partner Award from Hengxin Software and Yokogawa Automation

Sincere service, strength and responsibility In 2022, which was full of changes, Rittal and its partners Hengxin Software and Yokogawa Automation (part of the Yokogawa Group) withstood the challenges brought about by the pandemic and moved forward hand in hand. In the cooperation project, Rittal worked with the customer to overcome difficulties and complete the project delivery in a timely manner, ...

What is the difference between a control cabinet and a distribution box? What is the difference between a control cabinet and a distribution box?

One. The nature is different Distribution box: There is a large amount of parameter data in the distribution box. It generally constitutes a low-voltage distribution box. Control cabinet: The control cabinet is to assemble the switch cabinet, measuring instruments, protection devices and auxiliary equipment in a closed or semi-enclosed metal cabinet or screen according to the requirements of electrical wiring.

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the common decompression starting methods of cage asynchronous motors? Answer: (1) Three-phase resistance decompression start. (2) The reactor starts under reduced pressure. (3) Autotransformer decompression start. (4) Star delta decompression start. (5) Extension ...

Rittal guards the clear sea with the power of "wisdom". Rittal guards the clear sea with the power of "wisdom".

Under the development trend of "green + intelligence", the maritime industry is seizing innovation opportunities, promoting the use of information technology and artificial intelligence in onboard equipment, and actively exploring the development of green ships and intelligent ships. Rittal makes intelligence ubiquitous, empowers ship digitalization with technology, ...

What are the main classifications of Rittal cables – power cables? What are the main classifications of Rittal cables – power cables?

Classified by voltage level According to the voltage level, it can be divided into medium and low voltage power cables (35 thousand volts and below), high-voltage cables (above 110 thousand volts), ultra-high voltage cables (275-800 thousand volts) and ultra-high voltage cables (1000 thousand volts and above). In addition, it can also be divided into AC ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

How many types of protection devices are there for transformers? A: Overcurrent protection, current quick break protection, differential protection and gas protection. What are the requirements for relay protection? Answer: In order to be able to remove the fault correctly and quickly, it is required that the relay protection has sufficient selectivity ...

Rittal cabinets – maintenance rules for network cabinets Rittal cabinets – maintenance rules for network cabinets

1. Once a month (8 hours at the end of the month), and make a maintenance record. 2. Clean the gears of the whole machine to ensure the cleanliness and normal clearance of the gears. 3. Check the gap between the two gears at the punching device of the processing department and adjust the clearance. 4. Adjust the gap between each ink roller to ensure that ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top