1. Built-in air conditioner for heat dissipation
The cabinet is equipped with a refrigeration system, the evaporator and power devices are installed inside the cabinet in a closed manner, and the condenser and compressor are placed in the external circulation air duct or outside the cabinet. Since the power unit is sealed in the cabinet, as long as the appropriate sealing strip is used, it can completely isolate the outside dust ingress, so the dust protection level of the power unit can reach IP6X. This form of heat dissipation scheme can keep the cabinet at the best working temperature, but the structure of the air conditioner is complex, and the cost and use of energy consumption are large.
2. Heat exchanger heat dissipation
The cabinet with heat exchanger is completely isolated from the outside of the cabinet by sealing strips around the door panel, and the air in the cabinet is circulated internally, and the heat exchange is carried out between the heat exchanger and the outside air, which avoids dust from entering the cabinet and can achieve IP6X protection level. However, because the air in the cabinet and the air outside the cabinet can conduct the heat of the power unit to the outside of the cabinet for a second time of heat exchange, there is always a temperature difference between the ambient temperature of the cabinet and the outside of the cabinet, resulting in a higher ambient temperature of the electronic devices in the cabinet, so the failure rate of the electronic equipment is also greatly increased.
3. Liquid cooling and heat dissipation
Liquid cooling heat dissipation is mainly the use of liquid cold plate, centrifugal pump drives liquid flow through the liquid cold plate to achieve heat dissipation of power devices, compared with the traditional air conditioning and refrigeration system to save energy consumption, but the safety of this method is low, so the design and installation requirements are very strict. The dustproof method of this heat dissipation method is similar to that of air conditioner heat dissipation, and the cabinet is directly sealed to isolate the inside and outside, which can achieve IP6X protection level.
4. Forced air cooling and heat dissipation
Fan forced air cooling is suitable for high-power electrical equipment, easy to install and maintain, and low cost compared with other heat dissipation methods, so it is widely used in electrical cabinets. At the same time, because the forced air cooling adopts the mode of direct ventilation inside and outside the cabinet, the dust from the outside will inevitably enter the cabinet, so the position of the fan in the cabinet, the position of the air inlet and the air outlet, the layout of the power device, the installation direction of the board, and the smoothness of the air duct all affect the dustproof effect.
Among the above heat dissipation methods, only the cabinet with forced air cooling is more affected by dust and needs to be considered.
|
More on that
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the advantages of microcomputer automatic monitoring?
Answer: The device is small in size, high in reliability, has the functions of information storage, memory, calculation and logical judgment, and can collect, process, print and display the data.
What is overvoltage?
Answer: Put the pair of insulated ...
|
|
What are the common faults of Rittal cables – control cables?
1. The impact of lightning
The armor components of the control cable are all metal conductors, and if the power line is short-circuited or lightning hits the metal parts, a strong current will be generated to destroy the optical cable line equipment, and even casualties will occur in serious cases.
2. Optical cable ...
|
|
Rittal cabinet - judgment and treatment of energy storage faults in high-voltage switchgear
In the high-voltage cabinet with the spring energy storage operating mechanism, the energy storage must be stored in advance before closing. The energy storage mechanism is driven by an electric motor and the gear mechanism lengthens the spring. There are two types of operation methods: electric and manual. Manual failure to store energy should be due to a mechanical failure of the mechanism. Manual energy storage ...
|
|
What are the advantages of Rittal enclosure processing – sheet metal cabinets?
1. The cabinet and chassis products provide space for power supplies, motherboards, various expansion boards, floppy disk drives, optical disk drives, hard disk drives and other storage devices, and these spare parts are firmly fixed through the internal supports, brackets, various chassis screws or clips and other connectors inside the cabinet and chassis.
|
|
Introducing the Rittal Product Configuration System (RiCS).
The Rittal Configurator (RiCS) is a new system configurator for the Rittal system product. It will allow you to quickly select a custom-configured cabinet that meets your application needs. During the configuration process, you can view the configuration in real time through the visual 3D model. After the configuration is complete ...
|
|
Rittal cabinets – what do you need to pay attention to when tidying up your cabinets?
1. In principle, the power cord and network cable of the cabinet should be sorted out separately;
2. The placement of the equipment should be appropriate, avoid squeezing each other, avoid being too high or too low, and avoid being too close to each other;
3. If there are too many devices in the cabinet, the equipment should be numbered;
4. For each line ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is the material of the busbar?
A: Copper busbar, aluminum busbar and steel busbar.
What is the significance of busbar coloring?
Answer: It can increase the radiation capacity, which is conducive to heat dissipation, and the allowable load current can be increased by 12-15% after coloring.
...
|
|
What are the classifications of Rittal cabinets? What is the difference with a general cabinet?
1. What are the classifications of Rittal cabinets?
1. According to the function, it can be divided into: fireproof and anti-magnetic cabinet, power cabinet, monitoring cabinet, shielding cabinet, safety cabinet, waterproof cabinet, safe, multimedia console, file cabinet, wall-mounted cabinet.
2. According to the scope of application, it can be divided into: outdoor cabinets, ...
|
|
Rittal enclosures – operating precautions for low-voltage distribution cabinets
First, set posts and responsibilities. The power department of distribution box equipment should number, register, file, hierarchical management, clear responsibilities, and regularly carry out technical inspection and maintenance of the distribution box.
|
|
Rittal's new Maxi-PLS busbar system is launched!
In electrical switchgear, the external connection of high-current frame circuit breakers (ACBs) is usually achieved by connecting multiple cables per phase in parallel. When the conventional flat copper bar scheme is adopted, it is necessary to cut a number of bolt fastening holes on the standard copper bar to complete the connection of the cable.
|
|
Rittal & Lithium Battery The industrial transformation of the trillion-dollar new energy vehicle market
The power of the 10 billion market
With the help of continuous favorable policies, China's new energy vehicles have maintained rapid growth this year. According to data from the China Association of Automobile Manufacturers, the production and sales of new energy vehicles reached a new high in October, with a year-on-year increase of 87.6% and 81.7% to 762,000 and 714,000 units, respectively.
|
|
Rittal Cables – the scope of application for wires and cables
Power system
The wire and cable products used in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables, which are basically replaced by plastic power cables), rubber sheathed cables, overhead insulated cables, branch cables (replacing part of the busbars), ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is eddy current? What are the harms of eddy currents?
Answer: When an alternating current is passed through a wire, an alternating magnetic field is created around the wire. An induced current is generated inside the whole conductor in an alternating magnetic field, and because this induced current forms a closed loop inside the whole conductor, ...
|
|
Alarm code causes and diagnostic methods for Rittal cabinet air conditioners
Alarm code: A01
System message: Open the cabinet door
The cause of the Rittal air conditioner: the opening and closing of the door is not in the correct position
Diagnostic method: Check the changing position of the door and, if necessary, the connection status
Alarm code: A02
System message: The temperature in the cabinet is too high
...
|
|
Reliability ceiling - Rittal and the maritime industry talk about China's "ship talk"
The Age of Discovery, which began at the end of the 15th century, linked the world and was one of the most important historical steps in the process of human civilization.
In the 21st century, in the development trend of global interconnection and China's intelligent manufacturing, the shipbuilding industry has ushered in high-energy development prospects.
Smart ships, low...
|
|
Common faults and troubleshooting methods of oil coolers - Rittal cabinets
Fault symptom 1: insufficient cooling capacity
Cause analysis
(1) The room or box is not sealed or the thermal insulation performance is poor
(2) The evaporator frost is too thick
(3) The efficiency of the compressor deteriorates
(4) The expansion valve is too large or too small
(5) There are more ...
|
|
How many fault codes does a Rittal cabinet air conditioner have?
There are a total of 9 fault codes for Rittal cabinet air conditioners,
They are: F1, F2, F3, FF, EH, EP, EL, SF, HC.
Among them, F1, F2, and F3 represent improper use or failure of internal components;
FF stands for Regulation Circuit Fault; EH stands for High Temperature Fault;
E ...
|
|
Rittal X Kongsberg | Smart ship "Wei" can be expected
Smart ships are a key area clearly supported by national policies. Driven by policy guidance and innovation, China has achieved phased results in the research and construction of smart ships. As the world's leading provider of enclosure systems, Rittal has a wide range of applications in the marine and port sectors.
|
|
Rittal presents its modular data centre solutions
Now AI has been widely used in many fields, and while we enjoy the convenience brought by AI skills, we should also know that behind these AI skills are a huge amount of data processing and communication by weak servers, and then find the most efficient solutions.
|
|
What are the common cable management methods for Rittal cabinets – network cabinets?
1. The network cabinet distribution frame is fixed in place, the panel paper is loaded into the distribution frame on the front, and the tray is installed on the back.
2. Positioning of the cable management board, the direction of the cable management board should be determined before threading when positioning the cable management board, so that the cable management board does not need to twist the direction in the process of line management, and it can enter the ...
|
|