The difference between imitation Rittal and genuine Rittal
The quality and brand awareness of Rittal are good, and the application market is also large, but due to various reasons such as price, delivery time, service, etc., many customer groups do not want to use Rittal products, but choose to go to the manufacturer to order imitation Rittal products.
...
|
|
Rittal cabinets – judgment and handling of high-voltage switchgear closing faults
Closing faults can be divided into electrical faults and mechanical faults. There are two types of closing methods: manual and electric. Failure to close manually is generally a mechanical failure. Manual can be closed, electric can not close is an electrical fault.
1. Protection action: The protection action has been analyzed in front to trip the switch. ...
|
|
Rittal Cables – an introduction to the structure of industrial control cables
1. Conductor
It is the main component of the product to play its use function, and it is to transmit electricity or information, that is, to transmit electric current or electromagnetic waves on the conductor. The conductor is the basic and indispensable main component of the product for the transmission of electric current or electromagnetic wave information.
2. Insulation ...
|
|
A detailed presentation of Rittal's new smart electronic lock
With the development of data centers in the direction of more intelligent and high reliability, the information stored in the servers in the IT cabinet is becoming more and more important, and the operation and maintenance of the data center needs to be able to manage the door opening of the cabinet more effectively to avoid server downtime caused by human factors.
Traditional Mechanical Cabinet Locks ...
|
|
Rittal cabinet - judgment and treatment of sudden trip fault in operation of high-voltage switchgear
1) Fault phenomenon: The cause of this failure is the protection action. The high-voltage cabinet is equipped with protection against overcurrent, quick cut-off, gas and temperature.
2) Judgment method: The cause of the fault can be judged according to the relay card drop, remote signaling information, etc. After the action of gas and temperature protection in the high-voltage cabinet ...
|
|
How many fault codes does a Rittal cabinet air conditioner have?
There are a total of 9 fault codes for Rittal cabinet air conditioners,
They are: F1, F2, F3, FF, EH, EP, EL, SF, HC.
Among them, F1, F2, and F3 represent improper use or failure of internal components;
FF stands for Regulation Circuit Fault; EH stands for High Temperature Fault;
E ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the main parameters of the transformer?
Answer: (1) rated voltage; (2) Rated current; (3) Rated capacity; (4) No-load current; (5) No-load loss; (6) Short-circuit loss; (7) Impedance voltage; (8) Winding connection diagram, phasor diagram and ...
|
|
What you need to pay attention to when choosing a Rittal-like cabinet and a Rittal-like electrical cabinet
In recent years, Rittal cabinets have been increasingly used in important equipment and projects at home and abroad. This brand from Germany Rittal cabinet has always been a tall image in the industry, the fine quality is fascinating, and the high price makes us prohibitive. With the agility of China's manufacturing industry...
|
|
Rittal cables – the types of cables in detail
Flame retardant rubber sheathed cable
1. Use
This product is a series of mining rubber sheathed flexible cables. It is suitable for power connection of shearers and similar equipment devices with rated voltage Uo/U of 1.9/3.3KV and below. It is mostly used in coal mines.
2. Conditions of use
Long-term core ...
|
|
Rittal cables – type descriptions for power cables
The model of the power cable
1. Use the capitalization of the first letter of Hanyu Pinyin to indicate the type of insulation, conductor material, inner sheath material and structural characteristics. For example, Z is used to represent paper (zhi); L stands for Aluminum (LV); Q is for lead (qian); F stands for fen; ZR stands for Flame Retardant (zura...
|
|
Rittal cabinets – maintenance methods for low-voltage distribution cabinets
1. The purpose is to ensure the normal and safe operation of the low-voltage distribution cabinet and the control cabinet of each equipment.
Second, the scope is suitable for the low-voltage distribution room distribution cabinet, and the control cabinet of each equipment shall be implemented with reference to the relevant provisions according to the specific situation.
Third, the responsibility of the mechanical and electrical installation and maintenance engineering department maintenance team every six months ...
|
|
Running seamlessly, Rittal develops with reliable quality "pulsating" energy storage
Reliable supply wherever you are
Tesvolt's large-scale industrial battery storage systems are based on standard products made by Rittal and guarantee a continuous power supply on the top of a mountain, by the sea or in the desert.
The mountain peaks rise high above the crystal clear ...
|
|
Rittal Cables – the scope of application for wires and cables
Power system
The wire and cable products used in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables, which are basically replaced by plastic power cables), rubber sheathed cables, overhead insulated cables, branch cables (replacing part of the busbars), ...
|
|
How to use the Rittal basic controller for cabinet air conditioning
Carefully push the decorative panel back onto the monitor until you hear it snap into place.
· Reinsert the monitor into the panel or blind.
· Reinstall the louver pane or panel onto the cabinet air conditioner.
Reset the base controller
The air conditioner in the cabinet emits a high ...
|
|
Rittal Cabinet - Knowledge Q&A of High and Low Voltage Distribution Cabinet (21-30)
21. What does the workplace have to meet for high-voltage electrical appliances?
Answer: A. Rated voltage, B. Maximum working voltage, C. Rated current, D. Rated short-circuit interrupting current, E. Short-time withstand current and peak withstand current.
22. What are the basic requirements for a high-voltage circuit breaker?
Answer: A work ...
|
|
Rittal cables – classified according to the purpose of the cable and the environment in which it will be used
1. DC cable
(1) Tandem cables between components.
(2) Parallel cables between strings and between strings and DC distribution boxes (combiner boxes).
(3) The cable between the DC distribution box and the inverter.
The above cables are all DC cables, outdoor laying ...
|
|
What are the application areas of Rittal cabinets – cabinet air conditioners?
Indoor unit: suitable for all kinds of control boxes, distribution boxes and electrical cabinets in machinery, electric power, chemical industry, textile machinery, automation equipment, instrumentation and other industries with high requirements for temperature and humidity. It can also be used to regulate temperature and humidity in small spaces.
Outdoor unit: suitable for outdoor general base station, outdoor ...
|
|
What do you need to pay attention to when grounding the electrical control cabinet?
1. Make sure that all equipment in the electrical control cabinet is well grounded, and use short and thick grounding wires to connect to the common grounding point or grounding busbar. Any control equipment connected to the inverter should be co-grounded with it, and likewise ground with short and thick wires;
2. Flat conductors are used, e.g. ...
|
|
Rittal Cables - What are the main contents of cables?
1. SYV: solid polyethylene insulated RF coaxial cable, coaxial cable, radio frequency signal transmission in wireless communication, broadcasting, monitoring system engineering and related electronic equipment (including comprehensive coaxial cable)
2. SYWV(Y): Physical Foamed Polyethylene Insulated Cable TV System Cable, Video ...
|
|
What are the common faults of Rittal cables – control cables?
1. The impact of lightning
The armor components of the control cable are all metal conductors, and if the power line is short-circuited or lightning hits the metal parts, a strong current will be generated to destroy the optical cable line equipment, and even casualties will occur in serious cases.
2. Optical cable ...
|