Industrial wires and cables include single-core wires and cables, rubber cables, shielded control cables, flame-retardant cables, fire-resistant cables, etc.
Single-core wire and cable
It means that there is only one conductor in the insulation layer, the common BV wire, and B represents the wiring; V stands for insulating polyvinyl chloride. It is suitable for wires and cables used in meters, household appliances, and telecommunication equipment with an AC voltage of 450/750V and below.
Rubber sheathed cable
Refers to the flexible cable whose outer sheath is made of rubber, common YQ, YC, YZ, YH, suitable for the transmission and distribution of shearers or high-power mobile equipment with a rated voltage of 6/10kV and below, and this kind of cable can withstand large mechanical external force.
Shielded control cables
Refers to the cable shielded from external signal interference, KVVP is the code name of the shielded control cable, which is suitable for the connection between the electrical instrument with the voltage of AC rated 450/750V and below and the transmission line of the automatic control system; The KVVP cable itself has the functions of oil resistance, wear resistance, aging resistance, waterproofing and so on.
Flame retardant cables
It refers to the addition of flame retardant to the PVC insulation layer, even if it is burned in an open flame, its insulation layer will not burn, and it is mainly used for cable lines of 10kV and below.
Fire-resistant cables
In the event of a fire, the wires and cables can still be kept running for a certain period of time, providing time for extinguishing the fire and reducing losses.
|
More on that
|
Rittal X Kongsberg | Smart ship "Wei" can be expected
Smart ships are a key area clearly supported by national policies. Driven by policy guidance and innovation, China has achieved phased results in the research and construction of smart ships. As the world's leading provider of enclosure systems, Rittal has a wide range of applications in the marine and port sectors.
|
|
Rittal enclosures – Q&A on the basics of high- and low-voltage distribution cabinets
What is a substation?
A: It is a power supply hub that receives electrical energy from the power system, transforms (boosts or downgrades), and then distributes the power.
What is the main role of transformers in the power system?
Answer: The main function is to convert the voltage to facilitate ...
|
|
What do you need to pay attention to when wiring your Rittal cabinet – electrical control cabinet?
1. About the electrical part:
1. The input side and output side of the miniature circuit breaker are inverted.
2. The voltage of the coil of the electrical parts does not match the voltage of the drawing, especially the voltage of the small relay and indicator light is easy to error.
3. The positive and negative polarity of electrical appliances is reversed, and the internal polarity of DC electrical appliances is reversed.
|
|
How to deal with the A02 fault reported by Rittal air conditioner
1. Check whether the filter screen of the Rittal air conditioner is blocked, if it is blocked, clean the lower filter in time.
2. Check whether there is any remaining freon in Rittal air conditioner, and if not, inform the professional maintenance personnel of the air conditioner to add fluoride in time.
3. Check the function of Rittal air conditioner.
|
|
How do two Rittal cabinets fit together?
1. The power cords of the two cabinets are connected to the power socket at the rear of the cabinet.
2. The RS232 interface of the two cabinets is connected together with a communication cable.
3. Lock the door of the main cabinet, and turn on the power from the cabinet and the main cabinet in turn.
...
|
|
Rittal cables – the main use of power cables
Power system: The wire and cable products used in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables (basically replaced by plastic power cables), rubber cables, overhead insulated cables), branch cables, magnet wires and power equipment...
|
|
Rittal cabinets – the uses and characteristics of commonly used low-voltage distribution cabinets
▲ GGD AC low-voltage distribution cabinet:
(1) Use
GGD type AC low-voltage distribution cabinet is suitable for substations, power plants, factories and mining enterprises and other power users AC 50Hz, rated working voltage 380V, rated working current 1000-3150A distribution system, as a power ...
|
|
Rittal rittal stage coating method and function
Rittal coating method and function degreasing, nano-ceramic pretreatment, washing, used for anti-rust maintenance, used to improve the adhesion characteristics of lacquer. The conversion coating anodic dip primer of the nano-ceramic is evenly applied to the individual surfaces, edges and cavities. This constitutes a high corrosion protection ...
|
|
Presentation of the features of the Rittal cabinet TS8 seismic kit
Since ancient times, truss planning has been the way to create a stable and earthquake-tolerant mechanical structure. This plan consists of individual members connected at two ends, which form a triangle. The members are almost exclusively subjected to compressive or tensile forces, which makes the entire structure very strong.
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the main differences between electronic control equipment and power distribution equipment products?
Answer: The function of electronic control equipment is mainly control, and the function of power distribution equipment is mainly transmission.
How much is the external design of domestic electronic control equipment products?
Answer: Control panel, control cabinet, control box and console ...
|
|
Rittal cables – the types of cables in detail
Flame retardant rubber sheathed cable
1. Use
This product is a series of mining rubber sheathed flexible cables. It is suitable for power connection of shearers and similar equipment devices with rated voltage Uo/U of 1.9/3.3KV and below. It is mostly used in coal mines.
2. Conditions of use
Long-term core ...
|
|
Rittal cabinets – what do you need to pay attention to when tidying up your cabinets?
1. In principle, the power cord and network cable of the cabinet should be sorted out separately;
2. The placement of the equipment should be appropriate, avoid squeezing each other, avoid being too high or too low, and avoid being too close to each other;
3. If there are too many devices in the cabinet, the equipment should be numbered;
4. For each line ...
|
|
Rittal Cables – the operation of power cable routes
The operating voltage of the cable
Generally speaking, there is a certain relationship between the operating voltage of the cable and the rated voltage. If some cable lines are not in use, they must be connected to the power grid to ensure that the cable lines are not exposed to moisture. When the neutral point is not grounded ...
|
|
Rittal Cables – the main classification of wires and cables
Bare wire body products
The main characteristics of this type of products are: pure conductor metal, no insulation and sheath layer, such as steel core aluminum stranded wire, copper-aluminum busbar, electric locomotive line, etc.; The processing technology is mainly pressure processing, such as smelting, calendering, drawing, stranding/pressing stranding, etc.; The main products ...
|
|
Running seamlessly, Rittal develops with reliable quality "pulsating" energy storage
Reliable supply wherever you are
Tesvolt's large-scale industrial battery storage systems are based on standard products made by Rittal and guarantee a continuous power supply on the top of a mountain, by the sea or in the desert.
The mountain peaks rise high above the crystal clear ...
|
|
Rittal cabinets – the steps to organize your cabinets
1. Preliminary preparation
First of all, notify the user to label the cable and organize the cabinet without affecting the normal operation of the user.
Then, according to the topology of the network, the existing equipment, the number of users, the user group and other factors, the internal lines of the cabinet are delineated.
|
|
Analysis of the reasons why the Rittal Rittal cabinet air conditioner shows OL
The probable cause is the phenomenon of the compressor protection device tripping.
Compressor overload protection will trip, indicating that the system is too high-pressure, the pressure is too high, or the overheating current is too high.
Causes and elimination of high pressure and overheating:
1. Too much refrigerant. Reduce the refrigeration dose appropriately.
2, ...
|
|
Common faults and solutions for Rittal cabinet air conditioners
If the indoor temperature is higher than the outdoor one, or the indoor temperature is higher than the set temperature, the air conditioner will not start;
Solution: Test the temperature comparison between indoor and outdoor to check whether the indoor temperature is too high.
The voltage of the air conditioner is unstable, and the compressor cannot be started normally.
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the basic requirements for a high-voltage circuit breaker?
A: A. Reliable work;
B. Have sufficient circuit breaking capacity
C. Have the shortest possible cut-off time;
D. Simple structure and low price.
What is the purpose of the disconnector?
Answer: A. Electrical...
|
|
Rittal Cabinet - Knowledge Quiz of High and Low Voltage Distribution Cabinet (51-60)
51 What are the factors that affect the degree of harm to the human body caused by electric shock?
Answer: Factors such as the magnitude of the current, the duration of the current, the path of the current, the resistance of the human body and the frequency of the current.
52 Types of electric shock?
Answer: Direct electric shock, indirect electric contact, inductive ...
|
|