Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

What are the precautions for using current transformers?

Answer: 1. The secondary side shall not be open when working; 2. One end of the secondary side must be grounded; 3. The polarity of the terminal should be paid attention to when connecting.

  What are the precautions for using voltage transformers?

A:1. When working, its secondary side shall not be short-circuited; 2. One end of its secondary side must be grounded; 3. Pay attention to the polarity of its terminals when connecting.
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

More on that
Rittal cables – type descriptions for power cables Rittal cables – type descriptions for power cables

The model of the power cable 1. Use the capitalization of the first letter of Hanyu Pinyin to indicate the type of insulation, conductor material, inner sheath material and structural characteristics. For example, Z is used to represent paper (zhi); L stands for Aluminum (LV); Q is for lead (qian); F stands for fen; ZR stands for Flame Retardant (zura...

What is the difference between a control cabinet and a distribution box? What is the difference between a control cabinet and a distribution box?

One. The nature is different Distribution box: There is a large amount of parameter data in the distribution box. It generally constitutes a low-voltage distribution box. Control cabinet: The control cabinet is to assemble the switch cabinet, measuring instruments, protection devices and auxiliary equipment in a closed or semi-enclosed metal cabinet or screen according to the requirements of electrical wiring.

Rittal cabinet - distribution cabinet installation method, installation process and precautions Rittal cabinet - distribution cabinet installation method, installation process and precautions

First, the construction process Equipment unpacking inspection→ equipment handling, → cabinet (plate), basic installation, → above the cabinet (plate), bus preparation, → cabinet (plate), secondary circuit wiring, → cabinet (plate) test adjustment, → power transmission operation acceptance Second, the construction process 1. Equipment unpacking inspection, installation ...

Rittal cables – common causes of cable failure Rittal cables – common causes of cable failure

1. External force damage. Judging from the operation analysis in recent years, especially in Haipudong, which is developing rapidly, a considerable number of cable failures are caused by mechanical damage. For example, the cable laying and installation is not standardized, which is easy to cause mechanical damage; Engage in direct burial on cables ...

Rittal enclosures – how to choose the size of the cabinet? Rittal enclosures – how to choose the size of the cabinet?

1. Determine the size of the server, such as depth size, height size (how many U), and whether it is a 19-inch rack-mounted installation. 2. Choose a cabinet according to the installation space: If the server is a 19-inch rack-mounted installation, then a standard cabinet can be used. Root...

Rittal cables – safety requirements for cables Rittal cables – safety requirements for cables

1. When the cables cross each other, the high-voltage cable should be below the low-voltage cable. If one of the cables is protected by a pipe or separated by a partition within 1m before and after the intersection, the minimum allowable distance is 0.25m. 2. When the cable is close to or crosses the thermal pipeline, if there are thermal insulation measures, the flat ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

How many types of protection devices are there for transformers? A: Overcurrent protection, current quick break protection, differential protection and gas protection. What are the requirements for relay protection? Answer: In order to be able to remove the fault correctly and quickly, it is required that the relay protection has sufficient selectivity ...

How to deal with the A02 fault reported by Rittal air conditioner How to deal with the A02 fault reported by Rittal air conditioner

1. Check whether the filter screen of the Rittal air conditioner is blocked, if it is blocked, clean the lower filter in time. 2. Check whether there is any remaining freon in Rittal air conditioner, and if not, inform the professional maintenance personnel of the air conditioner to add fluoride in time. 3. Check the function of Rittal air conditioner.

Rittal Cables - Causes and countermeasures of line faults of power cables Rittal Cables - Causes and countermeasures of line faults of power cables

External damage: In the process of storage, transportation, laying and operation of cables, they may suffer external damage, especially the directly buried cables that have been run, and are prone to damage in the ground construction of other projects. Such accidents often account for 50% of cable accidents. In order to avoid such accidents, in addition to strengthening the cable ...

Rittal cables – the performance difference of control cables Rittal cables – the performance difference of control cables

The control cable has the characteristics of moisture-proof, anti-corrosion and anti-damage, and can be laid in tunnels or cable trenches. Power cables are used to transmit and distribute high-power electric energy in the main line of the power system, and the control cable transmits the electric energy directly from the distribution point of the power system to the power supply of various electrical equipment and appliances.

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is the material of the busbar? A: Copper busbar, aluminum busbar and steel busbar. What is the significance of busbar coloring? Answer: It can increase the radiation capacity, which is conducive to heat dissipation, and the allowable load current can be increased by 12-15% after coloring. ...

Rittal Cables – what are the ways to lay wires and cables? Rittal Cables – what are the ways to lay wires and cables?

1. Buried laying The laying method of laying the cable immediately underground is called buried laying. The buried cable must be armored cable and anti-corrosion coating protection cable, and the bare cable cannot be buried. Generally, the depth of the cable trench shall not exceed 0.9m, and the buried laying shall be paved ...

Reliability ceiling - Rittal and the maritime industry talk about China's "ship talk" Reliability ceiling - Rittal and the maritime industry talk about China's "ship talk"

The Age of Discovery, which began at the end of the 15th century, linked the world and was one of the most important historical steps in the process of human civilization. In the 21st century, in the development trend of global interconnection and China's intelligent manufacturing, the shipbuilding industry has ushered in high-energy development prospects.   Smart ships, low...

Some advantages of the Rittal compact AE enclosure Some advantages of the Rittal compact AE enclosure

The Rittal compact AE cabinet with its new internal expansion rails –Supplementary internal expansion for machining – Can be done in a time-saving manner in the side, bottom and top cover areas Installation – Two rows of adjustable TS 8 system holes for installation capacity Outer space...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the main technical parameters of the fuse? Answer: A. Rated voltage, B. Rated current, C. Breaking capacity, D. Melting characteristics, E. Overvoltage. What are the main products of low-voltage power distribution equipment? Answer: Low-voltage distribution panels, switch cabinets, switch boards, lighting boxes, power boxes and electrical ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is a busbar? Answer: In the voltage distribution devices at all levels of power plants and substations, the wires connecting engines, transformers and various electrical appliances are called busbars. What is the classification of busbars? Answer: soft bus (mostly used in outdoor power distribution room with high voltage) and hard bus (low ...

Alarm code causes and diagnostic methods for Rittal cabinet air conditioners Alarm code causes and diagnostic methods for Rittal cabinet air conditioners

Alarm code: A01 System message: Open the cabinet door The cause of the Rittal air conditioner: the opening and closing of the door is not in the correct position Diagnostic method: Check the changing position of the door and, if necessary, the connection status Alarm code: A02 System message: The temperature in the cabinet is too high ...

How to choose a distribution box for home renovation - Rittal How to choose a distribution box for home renovation - Rittal

1. Determine the material of the distribution box First of all, from the material selection, the distribution box on the market is divided into plastic and metal two materials, metal material is durable, strong resistance, but it is easy to rust and corrode when encountering water stains; Although plastic is light and cheap, it is not very durable. Therefore the root ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is a protective relay? Answer: It can reflect the failure or abnormal operation of electrical equipment in the power system, and act on the device that trips the switch or sends out a signal. What are the commonly used relays? A: Current Relay, Voltage Relay, Signal ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is eddy current? What are the harms of eddy currents? Answer: When an alternating current is passed through a wire, an alternating magnetic field is created around the wire. An induced current is generated inside the whole conductor in an alternating magnetic field, and because this induced current forms a closed loop inside the whole conductor, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top