Nazhi VR teaching

Create Date: 2024-8-30 12:03:23|Source: NACHI / Nachi Fujikoshi

NACHI is a long-distance teaching system that integrates VR technology and robots.
Nazhi VR teaching
  VR teaching is a teaching that wears VR glasses and sets the virtual space (VR) to a situation that is highly similar to the actual situation, and the obstacles on the way to transfer are restored under the simulated situation, so as to complete the imitation and teaching of the transfer of objects in the virtual space.

By giving instructions easily through the VR device, the robot can reproduce the transfer action, and the details are determined by AI.

It is possible to avoid interference between the robot and obstacles in advance, such as the movement of the robot itself, and plan a more suitable transfer path.

The operator is not on site, but the VR glasses can also complete the long-distance control of the robot. After VR teaching, perhaps one day in the future, robots will be able to show their powers in the distant universe.

NACHI's VR teach-in system solves the need for long-distance control of the robot, and the robot can be controlled by simple teach-in in the virtual space.

More on that
Nazhi PVD series piston pump Nazhi PVD series piston pump

Features of PVD series piston pumps: Compact Easy to use The internal oil drain structure does not need an oil drain pipe, and the pump is simple to exhaust Get the most out of your engine Constant power control for mini excavators is standard Multiple choices Can be combined with 1 or 2 ...

The Nachi Spot Welding Robot SRA series has been upgraded The Nachi Spot Welding Robot SRA series has been upgraded

In recent years, under the background of rising labor costs in China and Southeast Asian countries, the demand for automated spot welding robotization has increased year after year. When commissioning a robot in a unit, you will encounter problems with handling the cables and hoses of the unit. These pipelines will shake in response to the robot's movements, and the ...

Nazhi servo motor fault maintenance Nazhi servo motor fault maintenance

How to deal with the fact that the servo motor does not work when there is pulse output?   (1) Supervise the current value of the pulse output of the controller and whether the pulse output light is flashing, and admit that the command pulse has been executed and the pulse is now output normally; (2) Check the control cable from the controller to the drive, and ...

How to stop the Fujikoshi robot in operation How to stop the Fujikoshi robot in operation

In the process of manually operating the movement of the robot through the teach pendant, what should be done if the temporary demand aborts the robot?   Some friends may say that using the lever button can make the robot stop, this method is indeed ...

Nachi Fujikoshi LP130F high-speed palletizing robot Nachi Fujikoshi LP130F high-speed palletizing robot

Features:   High-speed handling Instantaneous maximum processing capacity: 1,800 bags/h (when handling 130 kg) 20% improvement compared to previous High-speed performance is achieved through a large-capacity motor and optimal enhancement of motion control ※Mode of action: Vertical ...

Take you to understand the characteristics of the Nachi Fujikoshi robot Take you to understand the characteristics of the Nachi Fujikoshi robot

Company Description: Founded in 1928, NACHI Fujikoshi has been engaged in the development of mechanical skills and machine manufacturing since its inception. The main factory is located in Toyama, Japan, and also has production bases in North America, South America, Europe and Asia, and has set up permanent representative aircraft around the world.

Measurement of the control cabinet of the Nachi Fujikoshi MZ12 Measurement of the control cabinet of the Nachi Fujikoshi MZ12

Nachi Fujikoshi MZ12 control cabinet measurement   1. Power supply voltage measurement, measure the incoming line voltage, driving voltage, and power module voltage of the robot, and sample the waveform of each voltage through the oscilloscope, so as to analyze the voltage as a whole. 2. Safety loop detection, check the safety ...

Advantages of the Nachifukoshi compact superspeed robot MZ04 Advantages of the Nachifukoshi compact superspeed robot MZ04

Clever cable arrangement for hollow wrists The robot cable is intelligently wired by means of a hollow wrist*. By simplifying the interspersed wiring to avoid interference with surrounding devices, the reliability of the equipment has been greatly improved. Compact, wide range of action Lightweight and compact ...

Nazhi PZH-1B-16N5-10 series new piston pump Nazhi PZH-1B-16N5-10 series new piston pump

Nazhi PZH series piston pump realizes continuous drive with an output pressure of 35MPa PZH-3B (2018-) Sold as our first high-pressure variable displacement piston pump for motors up to 90kW, it has low friction loss and internal leakage of each sliding part. ...

Analysis of the causes of the white screen of the teaching pendant of the Nazhi robot Analysis of the causes of the white screen of the teaching pendant of the Nazhi robot

1. The internal problems of the teaching pendant of Nazhi robot mainly include: LCD panel drive circuit problems, LCD panel power supply circuit problems, poor screen line contact, motherboard control circuit problems, etc. Second, the white screen of the teaching pendant of the robot may also be the video line contact...

Nazhi energy-saving hydraulic station Nazhi energy-saving hydraulic station

The main culprit of the greenhouse effect is "greenhouse gases", and the emission of carbon dioxide, one of the greenhouse gases, has become a global issue that needs to be solved urgently.   In order to alleviate the global warming effect, the Chinese government has strengthened its carbon dioxide emission control measures since 2015, and strives to achieve carbon dioxide emission control measures in 2015.

Analysis and diagnosis of the black screen fault of the MC50 teaching board Analysis and diagnosis of the black screen fault of the MC50 teaching board

1. Whether the power supply of the robot teach pendant is connected. Check whether the power supply of the Nazhi robot teach pendant is connected to the power supply and whether there is a short circuit in the power connection. 2. Whether the brightness, contrast and display position knobs of the Nazhi robot teach pendant are adjusted in the normal position. Will the robot teach ...

How to shut down the robot in case of emergency How to shut down the robot in case of emergency

During the operation of the robot, if there is an emergency accident, the operation of the machine can be forcibly suspended by an external emergency stop device.   1. External emergency stop device In the event of an emergency, how to quickly and accurately shut down the operation of the robot In each will be organic ...

NACHI Fujikoshi - ZT extrusion taps NACHI Fujikoshi - ZT extrusion taps

NACHI Fujikoshi--ZT Extrusion Taps Extrusion tap series No chips are generated, and stable machining is possible Extrusion taps for enhanced thread strength ZT coating It has excellent wear resistance, heat resistance, and low friction properties Sump ZT Blade (PAT. P) ...

How to deal with the inaccurate positioning of the position control of the servo motor? How to deal with the inaccurate positioning of the position control of the servo motor?

First of all, check whether the current value of the actual pulse emitted by the controller is as expected, and if not, check and correct the program: Monitor whether the number of pulse instructions received by the servo driver and the efficiency of the controller are checked in the control line cable; Check Servo Commands ...

Expert mode settings for Nachi bots Expert mode settings for Nachi bots

Expert mode settings The robot system is divided into several user levels: INTEGRATOR, SPECIALIST, and USER, and the user permission levels we commonly use are generally SPECIALIST and USER 2. After the robot is powered on and running, the default user level of the system is USE...

Matters that should be paid attention to when operating the robot Matters that should be paid attention to when operating the robot

The eyes are looking at the robot, not the screen. Pay attention to the direction of the robot while operating. There will be situations where the cable will be entangled in the direction of the wrist rotation, and the tool will touch the robot, so be sure to handle it carefully. In order to prevent these situations, the operator's visual vision is the only ...

Nachi Fujikoshi - GMS100 skiving gear machining center Nachi Fujikoshi - GMS100 skiving gear machining center

Nachi Fujikoshi skiving gear machining center   GMS100 Designed for electrical and electronics, EVs, reducers, aircraft, Multitasking machines developed for small parts in medical-related fields Specialty Skiving, hobbing, turning, drilling, etc Gear Fabricator ...

The setting of the working coordinates of the Nachifukoshi robot The setting of the working coordinates of the Nachifukoshi robot

Debug all the points in the empty program first The number of points needs to be 5 or more Select a constant setting Mechanical constants Tool settings Select the tool you want to modify Simple setup Enter the program number and click Execute ...

The fault solution of Nazhi servo motor The fault solution of Nazhi servo motor

How to deal with the inaccurate positioning of the intelligent servo motor for azimuth control?   (1) First of all, confirm whether the current value of the pulse announced by the controller is as expected, and if not, check and correct the program: (2) Supervise whether the number of pulse instructions received by the servo driver and the controller announce the ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top