Precautions for long-term idle use of Delta inverter

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems:

1. After the equipment is energized, the inverter will blow up the machine and the pre-circuit breaker will jump off.

2. After starting, the inverter panel is not displayed

3. The inverter runs normally after starting, but it fails after operation

4. The inverter runs normally after starting, but it appears to be a frying machine after operation

                               Precautions for long-term idle use of Delta inverter

Why is there a phenomenon of inverter failure described above?

1. The improper placement environment of the inverter will lead to the above problems.

2. The inverter is composed of rectifier module, IGBT and electrolytic capacitor and other primary components, during which if the electrolytic capacitor is not energized for a long time, it will cause the electrolyte in the electrolytic capacitor to dry up, so that the capacity decreases and the leakage increases. In this way, when the inverter is powered, the switching power supply operation will be abnormal or damaged, and in serious cases, this will lead to the electrolytic capacitor of the main circuit being damaged, resulting in the explosion of the inverter.

Why do some inverters still work normally after being placed for a period of time?

1. The inverter storage environment is good

2. The inverter has not been working for a long time under overheat or overload conditions

3. The service life of the inverter is short

4. The capacitance characteristics inside the inverter are better than **

How to prevent the inverter from powering failure?

1. If the inverter is not used for a long time, it should be sealed and stored in a dust-proof and moisture-proof environment, and the storage temperature is -25C-65C.

2. It is safer and more useful to use special equipment to charge the inverter regularly (once every 3 months) and check the input and output ports. 220 volts are supplied to a 380 volt inverter (110 volts are supplied to a 220 volt inverter) and the voltage slowly rises from 0 volts to 220 volts. The duration is determined according to the power of the inverter. Then, supply 380 volts (220 volts) to the drive and look at the input voltage. Only an imbalance of +/- 3% was promised.

More on that
The inverter reported the cause of the grounding fault - Delta The inverter reported the cause of the grounding fault - Delta

Regarding the grounding problem, it can generally be swept away after the following steps (because most of the inverters are not easy to detect the current measurement of Hall components, it is very important to sweep the grounding caused by external conditions, and alternative methods can be selected if there are conditions, and it is still an external problem to change a normal load to see whether it is a problem of frequency conversion or an external problem ...

Measures to avoid soft failure of inverters - Delta Measures to avoid soft failure of inverters - Delta

The ways to reduce the soft fault of the inverter are: 1. Detect the overvoltage and undervoltage of the inverter; 2. Detecting overcurrent is the most frequent phenomenon of frequency conversion alarm. Generally, the overvoltage alarm is generally presented at the time of shutdown, and the primary reason is that the deceleration time is too short or the braking resistance and braking unit have ...

Delta's soft starter component role Delta's soft starter component role

The soft starter is a device used to control the start and stop of the motor, which is composed of a number of components, including the soft starter controller, the soft starter conditioner, the soft starter power supply, the soft starter input and output module, the soft starter interface module, etc. ...

The inverter sets the characteristic parameters of the motor The inverter sets the characteristic parameters of the motor

1. Parameters to be set for the motor When the inverter (hereafter referred to as the -VFD) is operating in the "vector control" (F0-03=1) mode, it is highly dependent on accurate motor parameters, which is one of the important differences from the "VF controlled" (F0-03=2) mode. In order for the VFD to have outstanding driving ...

Inverter maintenance and accessories should be replaced regularly – Delta inverters Inverter maintenance and accessories should be replaced regularly – Delta inverters

1. Before the inverter is energized The temperature and humidity of the surrounding environment should be detected first. Too high a temperature will cause the inverter to overheat the alarm. When severe, it will directly lead to damage to the power supply device of the inverter and short circuit of the circuit; Excessive humidity of the air can lead to a direct short circuit inside the inverter. When the inverter is in operation ...

Debugging Delta's inverter method Debugging Delta's inverter method

In order to ensure the reliability of production, when Delta's inverter is planned to be equipped with power drive, in addition to meeting the power drive requirements, the remaining torque increases the consumption of active power. When using cost-effective Delta inverters to regulate the speed, if the flow requirements are reduced, by reducing the rotation of the pump or fan...

Precautions for the use of Delta inverters Precautions for the use of Delta inverters

1. The inverter must be selected correctly. 2. Read the product manual carefully, and wiring, device and application in accordance with the requirements of the manual. 3. The inverter device should be firmly grounded to suppress radio frequency disturbance and avoid electric shock caused by leakage of the inverter. 4、 ...

Advantages of sensorless vector control - Delta inverter Advantages of sensorless vector control - Delta inverter

Excellent open-loop speed control without slip compensation There is high torque at low degree, so there is no need to supply too much torque to enhance c. Lower loss, higher power Higher power echoes – especially for stepped loads Big...

Characteristics of common models of Delta inverters Characteristics of common models of Delta inverters

Delta MS300 Inverter Series: Delta's compact standard vector-operated inverter MS300 combines the advantages of miniaturization, high functionality, high trust, and simple installation, transforming every investment in industrial resources into abundant results. Optimized structure with lock-free screw terminals to plan the supply of bento ...

The technical advantages of the three-axis positioner - Delta The technical advantages of the three-axis positioner - Delta

1. The welding station is actively handed over, and the operator has been loading and unloading parts in a fixed position, which effectively reduces the labor and logistics intensity of the operator, and the welding products of the whole set of equipment have strong compatibility and strong automatic welding scalability. 2. All ...

How to choose the right Delta inverter for the motor How to choose the right Delta inverter for the motor

Delta's inverter has made the motor drive system complete two hopes: first, the motor has completed the operation of higher power; The second is to make the motor controllable and prevent the problem of the big cow pulling the trolley. But the problem in front of the engineer is: there are so many types of motor loads, and the frequency converter ...

Inverter Troubleshooting Skills - Delta Inverter Troubleshooting Skills - Delta

(1) The inverter drives the motor to jitter When repairing an Yaskawa 616PC5-5.5kW inverter, the customer indicated that the motor was shaking when sending it for repair, and the output voltage was unbalanced. After checking the power equipment, it was found that there was no damage, the inverter was energized and the display was normal, the inverter was operated, and the measurement ...

Precautions for storage of Delta inverter VFD-VE Precautions for storage of Delta inverter VFD-VE

It must be placed in a ventilated, dust-free, dry place. The ambient temperature of the storage location must be in the range of -10°C to +40°C The relative humidity of the storage location must be in the range of 0% to 90% and be free of dew. ...

Delta's inverter speed regulation application site Delta's inverter speed regulation application site

Inverter is a kind of speed regulating device, where to use the motor speed regulation, especially asynchronous motor speed regulation, will use the inverter, now mainly in industrial equipment has been used on a large scale, because the motor is the heart of the industry, and the three-phase asynchronous motor occupies the vast majority of the share, ...

Delta's inverter product model Delta's inverter product model

Delta's VFD inverters have established extensive brand awareness in industrial automation stores. Each series of products is designed for different operating needs such as torque, loss, overload, overspeed operation, etc., and is adjusted according to the characteristics of different industrial machinery; It can provide customers with a variety of choices, and a wide range of ...

The case of Delta's multi-axis motion controller The case of Delta's multi-axis motion controller

The non-standard manipulator can be customized according to the practical needs of customers, because the non-standard manipulator has no specifications to follow, and there is no such kinematic model in the controller, so the development of the control system is difficult. Delta recently provided non-standard manipulators for pharmaceutical board manufacturers to supply control solutions ...

The cause of the damage of the inverter - Delta inverter The cause of the damage of the inverter - Delta inverter

First, the heat dissipation of the inverter is not good In fact, we all know that too high a temperature has a damaging effect on any equipment, just like a human brain, too high a temperature will also burn out the brain, in fact, the same is true for inverters. When the temperature rises, because of the sensitivity of semiconductors to temperature, the inverter ...

Delta unveiled the ASDA-A2 series of AC servo motors and drives Delta unveiled the ASDA-A2 series of AC servo motors and drives

New Delhi, September 2, 2010 – Delta Group, the world's largest supplier of switching power supplies and brushless DC fans, is committed to innovation, energy efficiency and environmental protection, and has launched a new and advanced high-performance ASDA-A2 series of servo motors and servo drives for motion control and networking in India.

The robot reducer accessories are faulty The robot reducer accessories are faulty

Robot harmonic reducer is a kind of power transmission organization, which uses the speed converter of the gear to reduce the number of revolutions of the motor (motor) to the required number of revolutions, and obtains a larger torque organization. The scale of use of the reducer is quite extensive, if the noise of the reducer is too loud, it will hinder people ...

How to quickly master Delta servo? How to quickly master Delta servo?

  1: What is the difference between servo motor and general motor? The biggest difference between servo motors and general motors is the motor rotor and reaction equipment. The surface of the servo motor rotor is pasted with a strong magnetic steel sheet, so that it can be produced by the stator coil.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top