Tutorial on how to use a Fluke multimeter

Create Date: 2024-8-30 12:03:23|Source: FLUKE

Fluke Multimeter Tutorial.
Tutorial on how to use a Fluke multimeter
  Speakers, headphones, dynamic microphones: Using the R×1ω setting, any pen connected to one end and the other pen touches the other end, and it will normally make a crisp clicking sound. If it doesn't sound, the coil will break, and if the sound is small and sharp, there will be a problem of rubbing the coil and it can't be used.

Measuring capacitors: Use the resistance range, select the appropriate range according to the capacitor capacity, and pay attention to the black pen of the electrolytic capacitor when measuring, and connect the positive pole of the capacitor. (1) Estimate the capacity of microwave capacitors: according to experience or reference to standard capacitors of the same capacity, according to the maximum amplitude of pointer swing. The reference capacitors do not need the same withstand voltage values, as long as the capacitance is the same, for example, it is estimated that a 100μF/250V capacitor can be used as a reference with a 100μF/25V capacitor as a reference, as long as the maximum amplitude of their pointer swing is the same. (2) Estimate the size of the pico-level capacitance: to use the R×10kΩ range, but only the capacitance above 1000pF can be measured. For capacitors of 1000pF or a little larger, as long as the dial hand swings slightly, the capacity is considered sufficient. (3) Measure whether the capacitance leaks: for capacitors above 10,000 microfars, you can first use R×10Ω fast charging, and then preliminarily estimate the capacitance, and then change to R×100000pF or slightly larger capacitance, and then change to R×10000kΩ, then to R×1kΩ, then to R×1kΩ, and then to R×1kΩ.

The quality of drive test diodes, transistors and regulators: Because in the actual circuit, the bias resistance of the triode or the surrounding resistance of the diode and the regulator tube are generally relatively large, mostly above a few hundred ohms, we can use the R×10ω or R×1ω of the multimeter to measure the PN junction on the road surface. When measuring the pavement, the PN junction measured with R×10Ω should have obvious forward and reverse characteristics (if the difference between the forward and reverse resistance is not obvious, it can be measured with R×1Ω). In general, when the forward resistance is measured in the R×10Ω range, the gauge hand should indicate around 200Ω, and when the R×1 is measured, the gauge hand should be indicated at about 30Ω (it may vary slightly depending on the phenotype). If the forward resistance value is too large or the reverse resistance is too small, it means that there is a problem with the PN junction and there is also a problem with the pipe. This method is particularly effective when it comes to maintenance, where bad pipes can be found very quickly, and even pipes that have not been completely damaged but whose characteristics are damaged can even be measured. Compared to if you measure with a small resistance value, if you use a small resistance that is too large or the reverse resistance is too small, it will not work properly or work properly.

Measuring resistance: The important thing is the selection range. When the pointer indication is in the range of 1/3 - 2/3, the measurement accuracy is the highest and the reading is the most accurate. It should be noted that when measuring the European high resistance resistance with the R×10k resistance range, do not pinch your fingers at both ends of the resistance, so that the human resistance will make the measurement result smaller.

More on that
Fluke introduces the DSX Series for Versiv2 certification testing Fluke introduces the DSX Series for Versiv2 certification testing

You may be ready to get rid of the 2004 Toyota, which still uses a cassette recorder and has driven 280,000 kilometers and honestly, "It's a good car indeed!" Although you may still be using the now-discontinued DTX tester and have been working for the past few ...

Speed up air leak detection Speed up air leak detection

May 9, 2021 | Basics, Industrial Imaging, Troubleshooting, Energy Management Even the slightest air leak can add to product and energy waste and lose production time – for a production line that can't function properly without compressed air to run tools and processes...

Diagnose faults in process control systems from 4 to 20 mA without opening the loop Diagnose faults in process control systems from 4 to 20 mA without opening the loop

Field test control design Anyone who works in a manufacturing plant knows that there's nothing more devastating than an unplanned shutdown. Lost production time means lower yields, which can lead to huge price differences. In a process plant, if a breakpoint occurs at a critical point in the process ...

How to use Fluke Connect™ software with the Fluke 377 FC and Fluke 378 FC FieldSense™ clamps How to use Fluke Connect™ software with the Fluke 377 FC and Fluke 378 FC FieldSense™ clamps

The 377FC and 378FC clamp meters feature the new FieldSense™ technology, which enables you to measure voltage and current using the jaws. By integrating Fluke Connect software into many Fluke tools, including the 377 FC and 378 FC clamp meters, you can save on troubleshooting ...

Power Quality Measurement Technology Issue 4 - Causes and Hazards of Ultraharmonics? (Fluke) Power Quality Measurement Technology Issue 4 - Causes and Hazards of Ultraharmonics? (Fluke)

PWM converter equipment, the current waveform will produce distortion, ultra-harmonic current! Typical equipment that can produce ultraharmonic interference Grid-connected inverter for new energy Examples: photovoltaic, wind power, fuel cells, etc PWM rectifier equipment e.g. speed-regulating drive with active front-end (rectifier/feedback unit) ...

Fluke 301C Multi-Clamp Meter for Quality Control Engineers Fluke 301C Multi-Clamp Meter for Quality Control Engineers

"Before the test, the pump resistance of the machine should be measured, and the resistance diode capacitance can be switched by pressing the selection button, and the current and voltage can be measured at the same time, which is very convenient." 1. A variety of functions, one machine to get Before testing, the machine's water pump resistance should be ...

Why do Fluke DSX Series network testers need to be calibrated every year? Why do Fluke DSX Series network testers need to be calibrated every year?

A properly calibrated tester is a smart choice that can ultimately save you money. The right place to get your Fluke network tester calibrated is at one of our 13 authorized service centers around the world, just like those who drive long after the engine service light on the dashboard ...

Five test points to understand the efficiency and performance of the motor drive Five test points to understand the efficiency and performance of the motor drive

Motor drives are a ubiquitous technology that converts a constant voltage from an autonomous AC power source into a variable voltage that controls the torque and speed of the motor, making it ideal for use in motors that drive loads on mechanical equipment. Motor drives provide higher efficiency than simple in-line motors ...

Good news—Fluke 5560A high-performance multi-product calibrator wins the Automation Innovation of the Year Award Good news—Fluke 5560A high-performance multi-product calibrator wins the Automation Innovation of the Year Award

On February 24, the China Automation + Digital Industry Annual Conference and the 19th CAIMRS and Digital Leaders Forum hosted by the industrial control network were held in Suzhou. At the meeting, the new generation of high-performance multi-product calibrator 5560A brought by Fluke Metrology and Calibration Department won the "21st China Automation and Digital ...

Why is a Fluke multimeter so good? Why is a Fluke multimeter so good?

It continues to withstand a minute of 8KV high-voltage impact, it can withstand 3W plug-in test, it can withstand 5000 swing tests, it is unbeatable in the test test of millions of users, it is a Fluke multimeter! We all know that those who seem to have an effortless way to get the first ...

Fluke Networks announces the expansion of the network connectivity testing capabilities of the LinkIQ™ Smart Chainline + Network Tester Fluke Networks announces the expansion of the network connectivity testing capabilities of the LinkIQ™ Smart Chainline + Network Tester

Fluke Networks announced the upgrade of its LinkIQ™ Smart Link Pass Cable + Network Tester to expand its ability to test IP network troubleshooting and industrial Ethernet cabling with a user interface in 12 languages. New LinkIQ devices are equipped with the latest software. The product that has been purchased with ...

The Fluke II900 Industrial Acoustic Imager won the 2019 Product of the Year Award The Fluke II900 Industrial Acoustic Imager won the 2019 Product of the Year Award

On September 18, 2019, the authoritative annual new product selection activity in the field of industrial automation - CONTROL ENGINEERING China 2019 Best Product Award Ceremony was held in Shanghai Jinguyuan Howard Johnson Hotel, Fluke ii900 industrial acoustic imager, won the "Contr ...

Use the "sharp eye" to quickly find equipment failures and get twice the result with half the effort! Use the "sharp eye" to quickly find equipment failures and get twice the result with half the effort!

The Fluke VT08 portable thermal imaging camera can check the operation status of power distribution equipment, quickly locate the temperature measurement value of the observation target, take pictures to record the operation status of the equipment, and immediately find hidden dangers and problems in the equipment. Today we have invited a man who works in a cable company.

Fluke mA loop calibrator Fluke mA loop calibrator

The industry's most acclaimed and innovative precision loop calibrator Fluke offers the industry's broadest range of mA calibration and test tools for virtually all types of mA loop testing. The Fluke 710 combines pre-configured control valve testing capabilities, HART communication capabilities, and 0.0 ...

Fluke 5560A is a new generation of high-performance multi-product calibrator Fluke 5560A is a new generation of high-performance multi-product calibrator

Fluke Corporation of United States recently released a new generation of multi-product calibrators around the world, including three models: 5560A, 5550A and 5540A. This new series not only inherits the advantages and functions of the previous generation of products, but also makes many improvements, such as full Chinese color touch screen, full ...

Power Quality Measurement Technology Issue 6 - The Significance of THD at 40th, 50th and 100th Harmonics? Power Quality Measurement Technology Issue 6 - The Significance of THD at 40th, 50th and 100th Harmonics?

Everyone knows that THD is Total Harmonic Distortion, which is divided into voltage THD and current THD, which indicates the severity of voltage and current waveform distortion. The larger the harmonic content of the waveform, the more serious the waveform distortion and the larger the THD value. Conversely, the lower the THD value. That...

Fluke multimeter model Fluke multimeter model

A Fluke multimeter is a magnetoelectric meter that can measure a variety of electrical parameters such as AC and DC current, voltage and resistance.   Compared to other similar test tools, Fluke DMMs/multimeters are more widely used and have more comprehensive fault finding. All designs are tested to the limit: ...

How to choose the right clamp meter? How to choose the right clamp meter?

When Fluke introduced its first true RMS current clamp timer in the early '90s, it was a huge breakthrough that helped technicians find the root cause of transformer overheating, thermal neutralization, and circuit breaker tripping for no apparent reason. Its true RMS capability in the diagnosis by PC, electronic ...

Fluke infrared lenses Fluke infrared lenses

Infrared detection often requires the use of different lenses to view and analyze the temperature changes of certain extremely small or distant objects, and the lenses of the two newly released Fluke thermal imaging cameras provide a full view of these extreme targets. The 25 μm macro lens can identify ultra-micro targets on printed circuit boards, etc., ...

How to set up a mobile calibration lab - Fluke How to set up a mobile calibration lab - Fluke

It's no secret that to ensure the proper functioning of many industries, their equipment needs to be properly calibrated and a regular calibration schedule is implemented. Accurate measurement is always the key to the success of any manufacturing and production process. However, not every device can be sent to a calibration laboratory for calibration on a regular basis. Cause...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top