Fluke infrared lenses

Create Date: 2024-8-30 12:03:23|Source: FLUKE

Infrared detection often requires the use of different lenses to view and analyze the temperature changes of certain extremely small or distant objects, and the lenses of the two newly released Fluke thermal imaging cameras provide a full view of these extreme targets. The 25 μm macro lens can identify ultra-micro targets, such as on printed circuit boards, even defects that are difficult to see with the naked eye. The new 4x telephoto lens allows users to see distant targets at 4x magnification, enabling easy detection of targets such as power lines or tall flare towers.

Two new lenses expand Fluke's selection of thermal imaging camera lenses for resolutions 320×240 and below. Now, the Fluke lens line includes standard, wide-angle, macro, 2x, and 4x telephoto lenses – all with precision-manufactured germanium optics. All of these lenses are interchangeable between compatible cameras, eliminating the need to send the camera back to the factory for calibration, eliminating the cost of transportation and additional calibration.

Compatible with Fluke® TiX560, TiX520, Ti400, Ti300, and Ti200 thermal imaging cameras, the 4x telephoto lens helps identify issues such as failed splicing on small to high-voltage power lines in power stations, while ensuring technicians on the ground maintain safe measurements. In the petrochemical and metallurgical industries, where conditions such as explosive gases, extreme heat or dangerous voltages are crucial, a safe distance is essential, and telephoto lenses allow details to be seen at a distance.

Compatible with the Fluke TiX560 and TiX520 thermal imaging cameras, the 25 μm macro lens allows technicians to distinguish between temperature changes in ultra-micro targets smaller than the diameter of a human hair, making it ideal for electronics/printed circuit board R&D or any application that requires near-microscope-level IR resolution. The LaserSharp® laser autofocus button is used to set the focus of the lens at the optimal distance to obtain the need for precise focusing images, thus improving inspection efficiency.
Fluke infrared lenses

More on that
【Application case】The use of multimeter in the new energy industry 【Application case】The use of multimeter in the new energy industry

1. New energy photovoltaic industry Zhang Gong is the equipment department of a new energy company, which mainly manufactures solar cells through photovoltaic automation equipment. Zhang's daily work includes electrical maintenance, mechanical maintenance and software maintenance. The company has 9 large production lines, each with more than 30 machines...

Launch of the flexible and stand-alone in-line thermal imaging camera - TV30 Launch of the flexible and stand-alone in-line thermal imaging camera - TV30

Flexible and independent online thermal imaging camera - TV30 released The ThermoView TV30 is a mid-to-high-performance industrial thermal imaging system for process automation applications and critical asset monitoring. The TV30SA is a rugged, edge-computing, and highly integrated thermal imaging solution.

Fluke LinkIQ Fiber Package Fluke LinkIQ Fiber Package

The LinkIQ family of products offers the following features: · Highest qualified 10G speeds · Graphical display of open circuits, short circuits, misconnections, and fault locations · One-click test, no need to log in to the switch, you can get the switch name, port, VLAN, rate, and duplex status ...

Diagnose faults in process control systems from 4 to 20 mA without opening the loop Diagnose faults in process control systems from 4 to 20 mA without opening the loop

Field test control design Anyone who works in a manufacturing plant knows that there's nothing more devastating than an unplanned shutdown. Lost production time means lower yields, which can lead to huge price differences. In a process plant, if a breakpoint occurs at a critical point in the process ...

Power Quality Measurement Technology Issue 4 - Causes and Hazards of Ultraharmonics? (Fluke) Power Quality Measurement Technology Issue 4 - Causes and Hazards of Ultraharmonics? (Fluke)

PWM converter equipment, the current waveform will produce distortion, ultra-harmonic current! Typical equipment that can produce ultraharmonic interference Grid-connected inverter for new energy Examples: photovoltaic, wind power, fuel cells, etc PWM rectifier equipment e.g. speed-regulating drive with active front-end (rectifier/feedback unit) ...

Emissivity Emissivity

Emissivity refers to the ratio of the energy radiated from the surface of an object to the energy radiated by a blackbody at the same temperature. (A blackbody is an idealized radiator that radiates all of its energy and has an emissivity of 1.00 on its surface) The emissivity of various substances is determined by the material of the object itself.

Fluke introduces the RaySafe 452 multifunction radiometer Fluke introduces the RaySafe 452 multifunction radiometer

The RaySafe 452 is a powerful and versatile radiation measuring instrument for all types of ionizing radiation detection, from searching for isotope radioactive sources, measuring leaked rays from X-ray machines and linear accelerators, to measuring various α, β surface contamination in nuclear medicine. Within seconds of turning on the instrument, ...

How to choose the right clamp meter? How to choose the right clamp meter?

When Fluke introduced its first true RMS current clamp timer in the early '90s, it was a huge breakthrough that helped technicians find the root cause of transformer overheating, thermal neutralization, and circuit breaker tripping for no apparent reason. Its true RMS capability in the diagnosis by PC, electronic ...

Fluke network cable tester principle and features Fluke network cable tester principle and features

Fluke network cable testers are usually used to test whether the connection mode of the crystal head connected to both ends of a network cable is smooth, which helps to determine whether the network cable is in good condition, and can also test whether the crystal head is connected correctly. There are usually two ends, one is the main test end and one is the remote ...

Fluke Endoscopes Application Guide + Precautions Fluke Endoscopes Application Guide + Precautions

An endoscope is an optical instrument that is fed into the body from outside the body through the human cavity and then examines for problems in the body. Through this examination, the lesions of the organs can be viewed, their location and extent can be determined, and biopsy or smear can be performed, which can not only effectively diagnose the disease, but also ...

In one second, it was found that the catchment drain of metallurgical equipment was blocked, and good equipment was comparable to "perspective eye"! In one second, it was found that the catchment drain of metallurgical equipment was blocked, and good equipment was comparable to "perspective eye"!

In the field of Fluke infrared thermal imaging, there is a classic product that has been sold for more than ten years - VT04 visual infrared thermometer. And now, Fluke actively listens to customers' voices, explores user needs, and has comprehensively upgraded this thermometer, which has become a hot seller as soon as it was launched.

Fluke teaches you how to quickly test counterfeit cables Fluke teaches you how to quickly test counterfeit cables

Background: The Okay Cable incident actually reflects the long-standing problem of counterfeiting and shoddy products in the cable industry. In fact, as Party A (owner) and Party B (project contractor), when selecting cable products or cable warehousing, you can do a quick test on the cable products that are planned to be purchased or have been purchased.

Fluke 418X - the calibration tool for infrared thermometers Fluke 418X - the calibration tool for infrared thermometers

Temperature and control in industrial production are very important, the accuracy of temperature measurement determines the quality of products, and temperature parameters also play a vital role in product production efficiency and safe and reliable operation of production lines. For example, advanced infrared measurement has been gradually adopted in heat treatment and thermal processing.

Fluke mA loop calibrator Fluke mA loop calibrator

The industry's most acclaimed and innovative precision loop calibrator Fluke offers the industry's broadest range of mA calibration and test tools for virtually all types of mA loop testing. The Fluke 710 combines pre-configured control valve testing capabilities, HART communication capabilities, and 0.0 ...

What is a real RMS? What is a real RMS?

A true RMS device (RMS = Root Mean Square) is one of three tools that can measure alternating current (AC) or alternating voltage: RMS Digital Multimeter (or Clamp Meter) Average Response Digital Multimeter (or Clamp Meter) oscillograph Only the first two tools are commonly used ...

What is a thermal imaging camera? What is a thermal imaging camera?

Infrared radiation (heat) emitted by the measured target is passively received and this heat is converted into a temperature number All objects above absolute zero (-273*C) emit infrared radiation). ...

New Product Releases | Photovoltaic multi-function IV curve tester New Product Releases | Photovoltaic multi-function IV curve tester

All-in-one functionality Competent in PV system performance and safety testing Ground on-resistance Visual inspection Save data locally Start the test with one click Automated testing polarity Open circuit voltage Voc Short-circuit current IsC AC/DC power Insulation resistance I-V curve Diodes and surges ...

The past and present of Fluke's popular multimeter The past and present of Fluke's popular multimeter

45 years of history Fluke has been in China for 45 years, and in those 45 years, we have served millions of engineers and become a good assistant to engineers, helping them solve problems quickly, improve efficiency, and achieve results. In Fluke's hand-held meters, the multimeter does ...

Fluke 55X0A High Performance Multi-Product Calibrator Fluke 55X0A High Performance Multi-Product Calibrator

· A single instrument constitutes a small calibration laboratory · Multiple signal output of single machine • Matching options to calibrate a wide range of electrical products · Full-color touch screen, friendly operation interface

【New Product Evaluation】Lighter, thinner, durable 【New Product Evaluation】Lighter, thinner, durable

The just-launched Fluke 301 blade series clamp watch has received a lot of attention and praise from engineers because of its lighter and thinner body design. What about the durability of the new plier meter, let's take a look! Xiaofu also shares with you, How does the Fluke 301 be lighter and more ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top