Description: The Fisher CSB700 Pressure Reducing Regulator Direct Acting Spring-Loaded Regulator is designed for a wide range of pressure reduction applications. The regulator offers great flexibility because it offers a variety of body sizes and end connections, outlet pressure settings, and internal and external take-off options. The CSB600 series also offers a variety of overvoltage protection options to meet your application needs.
Product parameters
Body size and face connection ball
Graphite cast iron: 1-1/2 or 2 NPT, Rp 1-1/2 or 2, NPS 2 / DN 50 CL125 FF, NPS 2 / DN 50 CL150 FF, NPS 2 / DN 50 PN 10/16, NPS 1-1/2 / DN 40 PN 16 slide
WCC steel: 1-1/2 or 2 NPT, Rp 1-1/2 or 2, NPS 2 / DN 50 CL150 RF, NPS 2 / DN 50 PN 10/16
Maximum operating inlet pressure
Internal Strength (IS): 5 bar / 73 psig
Differential Compressive Strength (DS): 16 bar / 232 psig
Maximum emergency inlet pressure
Internal Strength (IS): 5 bar / 73 psig
Differential Compressive Strength (DS): 20 bar / 290 psig
Outlet pressure range: 9 mbar to 4.0 bar / 0.13 to 58 psig
Maximum Emergency Outlet (Housing) Pressure: 5.0 bar / 73 psig
Maximum Outlet Pressure to Avoid Damage to Internal Metal Parts: 1.5 bar / 21.8 psig - not exceed the maximum emergency outlet pressure
Temperature range
According to PED standards: -20 to 66°C / -4 to 151°F
Non-PED: -30 to 66°C / -22 to 151°F
Approximate weight
Threaded body:
Model CSB700: 13 kg / 29 lb
Model CSB704: 14 kg / 31 lb
Flanged body: Add 5.2 kg / 11 lb to the weight listed
Features:
A variety of body sizes and end connections are available
A model VSX8 shut-off valve option is available
No special tools are required to adjust the pressure and perform orifice removal
This article introduces Fisher/Fisher CSB700 pressure regulator products, if you are interested in Fisher/Fisher pressure regulator, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only by being professional and careful in every process, every action and every detail of the service can we meet or even exceed customer expectations and make customers satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy. Safety relay products, if you are interested in Fisher/Fisher pressure reducer, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Fisher/Fisher 2052 Spring & Diaphragm Rotary Valve
The Fisher 2052's highly versatile features and compact actuator design assist with throttling or on/off applications. It can be installed on any valve, even when space is limited.
specification
Actuation method: spring return, quarter-angle rotation, rotation
Certified PED compliant ...
|
|
Fisher/Fisher Model 92S Self-Operated Control Valve
The Model 92S self-actuated control valve is piston-actuated and can be used in high circulation steam applications. The base of the Model 92S control valve and pilot has an abrasive surface that has been shown to minimize base leakage. Both the 6492H and 6492L commanders are equipped with bellows to reduce guide rod friction ...
|
|
Fisher/Fisher 8580 High Performance Butterfly Valve
Fisher™ 8580 High Performance Butterfly Valve |
The Fisher 8580 High Performance Butterfly Valve features enhanced shut-off with an eccentric mounting butterfly plate with soft or metal seals. This control valve provides an excellent throttling and switching performance experience.
Authentication...
|
|
Fisher/Fisher D2T FloPro Control Valve 2250 psig pressure drop force
Introduction: The Fisher/Fisher D2T valve is best suited for use as a dump valve for gas separators and scrubbers. It is also suitable for other high-pressure applications in natural gas production, compression and processing.
Features:
Optional 1 NPT end connection.
Have a C ...
|
|
Fisher/Fisher Series 912 Pressure Reducing Regulator - LPG
The Series 912 direct-acting, spring-loaded regulators are United States Safety Testing Laboratories Corporation (UL) certified regulators for use in a variety of applications and industrial applications. The valve membrane of these regulators has some internal pressure relief to help minimize overpressure.
peculiarity
...
|
|
Fisher/Fisher DMA/AF desuperheaters in a variety of shapes
The Fisher DMA/AF is a multi-shaped, mechanically atomized, backpressure-activated superheater interstage desuperheater. Designed for applications that require control of moderate load fluctuations and high thermal cycling.
specification
Certified PED, CRN
Severe service steam conditioning
Materials SA105, F22, F91
Job...
|
|
Fisher 167D-2594-179127 Switching Valve 167DA Position Retention Valve
Fisher 167D-2594-179127 Switching Valve 167DA Retaining Valve The 167D Series Switching Valve is typically used to provide reduced, stable vaporized liquid pressure to pilot-acting controllers and other pneumatic instruments.
Models 167D and 167DS valves are two-way switching valves. 167DA and 167DA ...
|
|
Fisher/Fisher Series 1805 Series Back Pressure Regulators and Relief Valves
The Series 1805 pressure relief valve is ideal for farm faucet applications where a pressure relief valve is required between the primary and secondary regulators. The Series 1805 pressure relief valve is suitable for use with natural gas, air, propane, or any medium that is compatible with internal valve components. Relief ranges from 5 to 125 psig/0. ...
|
|
Fisher/Fisher Model R231A Integrated Two-Stage Regulator
The Model R232A regulator is certified by Underwriters Laboratories (United States Safety Testing Laboratories, Inc.) for use in LPG systems. The regulator is designed to reduce tank pressure through an integrated two-stage system that provides an 11-inch water column of outlet pressure. For the people ...
|
|
Fisher/Fisher Model MR105 Direct-Acting Vacuum Liquid Regulator
The Model MR105 Direct Acting Pressure Reducing Regulator is a high-flow, multi-purpose regulator designed to provide fast and economical pressure control for a wide range of applications with different fluid media such as liquids, air, and gases. The MR105 valve is the most important for response speed.
|
|
Fisher/Fisher H200 Series Pressure Relief Valves
The H200 Series Pop-Up Pressure Relief Valve is a direct-acting pressure relief valve with a pre-installed and fixed spring retaining ring. When the inlet gas pressure exceeds the spring set value, the lift assembly and disc assembly will be pushed away from the valve hole. The H200 Series Pop-Up Pressure Relief Valve is easy to operate and has a spring setting of ...
|
|
Fisher/Fisher A31D double flange butterfly valve
The Fisher A31D is a double-flanged high performance butterfly valve with either a splined or flat key actuated shaft. The A31D is used in throttling or on/off applications and models include NPS 3 to 12, CL150, and CL300.
Certified PED, CRN, Fugitive Emissions, NACE, ATEX, CUTR, Fire Safety...
|
|
Fisher/Fisher 67C Series High Pressure Regulator LPG
Description: The Fisher/Fisher 67C series of high-pressure regulators is a high-pressure regulator for a variety of liquid or vapor applications. The Series 67C basic regulator is equipped with wrench adjustment, handwheel adjustment, dial adjustment pattern with calibration scale or non-adjustable vandal spring ...
|
|
Fisher/Fisher 3610J Pneumatic, Single-Acting Positioner
The Fisher 3610J pneumatic positioner can be used with a single-acting rotary actuator to precisely locate control valves used in throttling applications. These positioners are rugged and provide valve positioning proportional to the pneumatic input signal or DC current input signal and as a whole ...
|
|
Fisher 3610JP Pneumatic Double Acting Valve Positioner
The Fisher 3610JP pneumatic positioner can be used with a double-acting rotary actuator to locate control valves used in throttling applications. These positioners are rugged and provide valve positioning proportional to the pneumatic input signal or DC current input signal and as a whole ...
|
|
Fisher/Fisher Model 630R Pressure Relief Valve Internal Pressure Extract
Introduction: Model 630R is a general purpose pressure relief valve available in NPS 1 and 2 / DN 25 and 50 body sizes for compressor stations, refineries and similar plants requiring back pressure gas regulation settings up to 250psi/7.2bar. A variety of high and low voltage structures are available. Low-voltage equipment ...
|
|
Fisher/Fisher dirty service trims
Fisher dirt service trims are designed for dirt and cavitation applications. Cavitation is eliminated with a range of flow limits and extensions, allowing particles up to 19mm (3/4in) in diameter to pass through without clogging. Each trim stage has a sequentially increasing flow ...
|
|
Fisher/Fisher DSA Vapor Regulated Desuperheater Pressure Rating ASME
Introduction: The Fisher/Fisher DSA steam conditioning desuperheater uses high-pressure steam to rapidly and thoroughly atomize water jets in a low-flow steam line. The desuperheater is flanged to a pipe with DN 200 (NPS 8) or larger. This desuperheater is suitable for applications that require a high turndown ratio.
...
|
|
Fisher/Fisher Valve DVC6010F-SCAD
F1 ELDVUEDVC6000 Series Digital Valve Controller (Fig. 1) and Actuator. The digital valve controller receives the valve stroke position in Figure 2) is a communicative, microprocessor-based conversion of electrical signals into feedback, as well as air supply pressure and pneumatic pressure of the actuator. This makes ...
|
|
Fisher/Fisher GX Control Valve Valve size standard NPS
Introduction: Fisher/Fisher GX control valve and actuator systems are designed with state-of-the-art technology in a small form factor for a wide range of process gases, vapors, and fluids, and are rugged, reliable, and user-friendly. It does not need to adjust the size of the actuator, once the valve ...
|
|