Fisher/Fisher 4660 Pneumatic High and Low Pressure Conductor
The Fisher 4660 pneumatic pilot-operated pressure controller activates a safe shutdown system for flowlines, production vessels, and compressors. The pilot is available in single or dual setpoint capability models that use a switching point to maintain full output pressure when the process pressure is within the set point range. If the process ...
|
|
Fisher/Fisher 4300 TempLow Steam Desuperheater
Fisher Yarway probe TempLow desuperheaters automatically introduce cooling water into the steam stream based on pneumatic or electrically controlled signals, providing precise and cost-effective control of steam temperature.
specification
Critical maintenance steam conditions
Equal percentages of flow characteristics, linearity, corrections, etc
Operating temperature ...
|
|
Fisher/Fisher V500 Clamp Offset Eccentric Control Valve
Simple installation—The one-piece body flange can be matched with many different types of pipe flanges to meet a variety of pipe requirements. Flanges help reduce exposed pipe flange bolting, shorten alignment and installation time, facilitate safety valve installation, and improve pipe tightness. Clamp valves in the pipeline ...
|
|
Fisher/Fisher Model SR5 Sanitary Pressure Regulator
The Fisher Model SR5 Regulator is a compact, high-flow, self-acting pressure reducer. It is designed for applications where hygienic design is extremely important, such as in the pharmaceutical, biotechnology or food and beverage industries. The unit is available in body sizes NPS 1/2 to 3 / DN 15 to 80 as well as ...
|
|
Fisher/Fisher Control-Disk™ Rotary Valve Flanged Version
Introduction: Fisher/Fisher Control-Disk™ rotary valves have excellent regulation performance. Compared to segmented ball valves, its equal percentage flow characteristics allow for a wider range of adjustments. This improved performance allows the valve to be controlled without process interference, allowing for better control of the target.
|
|
Fisher/Fisher 4320 Wireless Position Monitor
The Fisher 4320 Wireless Position Monitor requires no wiring to connect to a pneumatically actuated on/off valve. It utilizes the percentage of range and on/off indication to indicate the device position with a precise wireless feedback signal. The 4320 can be used to control and/or monitor valves, linear pressure regulators, displacements, and floats.
|
|
Fisher/Fisher A31A Low Temperature High Performance Butterfly Valve Double D Drive Shaft
Introduction: Fisher/Fisher A31A low-temperature, high-performance butterfly valves are designed for extreme temperature, cryogenic applications, with an extended body that keeps encapsulated systems and actuators away from extreme temperatures. The valve also features a metal NOVEX eal seal that provides tight shut-off, low operating torque and ...
|
|
Fisher/Fisher 6060 WhisperTube Modal Denoiser
The WhisperTube is a passive reactance silencer that is installed downstream of a control valve or other device that generates system noise. The pressure drop across the device has a negligible effect on the WhisperTube, so the system can be reduced in a wide range of operating conditions without impacting flow or process.
Peculiarity...
|
|
Fisher/Fisher Vee-Ball™ V150E Control Valve
The Fisher V150E Vee-Ball Control Valve features a flanged enlarged outlet design. The outlet flange has a standard pipe size diameter that is larger than the inlet diameter. The streamlined structure of the expanded outlet geometry helps the liquid flow smoothly through the valve as the flow area from the inlet to the outlet increases. ...
|
|
Fisher/Fisher 657 and 667 diaphragm actuators
The Fisher 657 and 667 actuators are designed to ensure stable on/off or throttling operation of the control valve. These spring-balanced diaphragm actuators determine the position of the valve spool in response to a changing pneumatic output signal from the controller or valve positioner. 657 Actuators ...
|
|
Fisher/Fisher Model R622 Pressure Reducing Regulator
The Fisher Model R622 direct-acting, spring-loaded regulator provides economical pressure reduction control in a variety of residential, commercial, and industrial applications. These regulators can be used for natural gas, manufactured gas, or LPG with the same inlet and outlet pressure capabilities.
peculiarity
Compact...
|
|
Fisher/Fisher R222 Series Secondary Regulators
The R222 series regulators are certified by Underwriters Laboratories (United States Safety Testing Laboratories, Inc.) for use in LPG two-stage pressure regulating systems. The unit reduces the outlet pressure of the primary regulator (typically from 10 psig / 0.69 bar) to 11-in ...
|
|
Fisher/Fisher 2052 Spring & Diaphragm Rotary Valve
The Fisher 2052's highly versatile features and compact actuator design assist with throttling or on/off applications. It can be installed on any valve, even when space is limited.
specification
Actuation method: spring return, quarter-angle rotation, rotation
Certified PED compliant ...
|
|
Fisher/Fisher POSI-SEAL A11 rotary control butterfly valve
A control valve is a valve that is fully or partially opened or closed in a pipeline according to the process signal to control the flow, pressure, temperature and liquid level. Information on Fisher®, Baumann™ and POSI-SEAL™ brand control valves can be found via the links on this page.
...
|
|
Fisher/Fisher 8590 High Performance Butterfly Valve Multiple connections
Introduction: The Fisher/Fisher 8590 High Performance Butterfly Valve maintains tight shut-off and can be specified for a wide range of pressure and temperature conditions. The 8590 valve is available in a lug-style body design. The splined shaft can be connected to a variety of springs and valve membranes or pneumatic pilot actuators, and the square shaft or keyway shaft can be ...
|
|
Fisher/Fisher 1301 regulator
The 1301 series is a high-pressure pressure regulator used to supply air to instruments. It is equipped with a pressure gauge interface and can be equipped with a pressure gauge as an option.
Connection size: NPS 1/4
Regulated pressure range: .0.69 to 34.5 bar/10 to 500 psig
Maximum inlet pressure: 414bar/6000psig
This article describes the fee ...
|
|
Fisher/Fisher Series 289 Pressure Relief Valve or Back Pressure Regulator
The Fisher Series 289 Pressure Relief Valve is a spring-loaded, throttled pressure relief valve that can be used as a downstream pressure regulator to prevent overpressure in the system. Smooth throttling during pressure relief operation minimizes pressure shocks in the system. The Series 289 Pressure Relief Valve is ideal for low pressure settings.
|
|
Fisher/Fisher Model R222H Primary Regulator for LPG
Introduction: The Fisher/Fisher Model R222H is a one-stage regulator that offers 65% higher flow and 40% smaller volume than standard compact regulators for use in underground tanks or airchambers where space is limited. Approved by Underwriters Laboratories (UL) (United States Safety Testing Laboratories Inc. ...
|
|
Fisher/Fisher 1077 Manual Handwheel Actuator
Locking it by adjusting the stroke limiter provides accurate disc and ball positioning in both the closed position (0 degrees) and the open position (90 degrees). For 60-degree operation, a stroke limiter can be used to establish a valve disc or ball closure stop at any angle between 0 and 30 degrees.
|
|
Fisher/Fisher pipe silencer
Complete Fisher pipe silencers provide superior noise reduction performance for applications where valves generate a lot of noise. Once installed, the total system pressure drop is split between the valve and the silencer. This allows the valve to operate at a lower pressure drop ratio, reducing the noise generated during the flow through the control valve.
|