The Fisher DVI desuperheater is injected with a water jet at the venturi outlet section to ensure thorough mixing as well as rapid atomization. DVI desuperheaters can be easily installed between flanges in steam pipes from DN25 to DN600 (1 to 24 inches). There are no moving parts, and the water fill mode allows for fast, thorough cooling. It is mainly used in applications with moderate load fluctuations and low flow rate steam.
specification
Certified PED, CRN
Severe service steam conditioning
Materials SA105, F22, F91
The operating temperature is high
Stress Rating ASME
Process connector type: flange type, butt welding, RTJ, socket welding
Valve sizes NPS 1 to 24
Valve size standard NPS
This article introduces Fisher/Fisher DVI vapor conditioning desuperheater products, if you are interested in Fisher/Fisher pressure regulators, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
Fisher/Fisher easy-e ES Control Valve
Fisher easy-e ES valves are the ideal solution for a wide range of applications, including sulfide and chloride stress cracking environments common in the oil and gas production industry. Available with ball or angle bodies, these valves provide up to Class V or Level VI shut-off.
specification
Certified in accordance with ...
|
|
Fisher/Fisher Models 1808 and 1808A Pressure Relief Valves or Back Pressure Regulators
Fisher's 1808 Spherical and 1808A Angle-Directed Back-Pressure Regulators or Relief Valves are economical and compact for use in gas or liquid applications to maintain pressure on oil-gas separators, or for pressure relief applications in gas distribution systems.
peculiarity
The design is simple and reliable
Compact and lightweight
Square...
|
|
Fisher/Fisher V280 Full Bore Ball Control Valve
The Fisher V280 is a three-piece, trunnion-style, full-bore control valve that handles all CL900 pressure drops. Optimized pressure, flow, and process control. An optional borehole silencer controls noise and vibration from high-pressure drop liquids and gases. The spline shaft is connected with the actuator, which reduces the ...
|
|
Fisher/Fisher Model 92C Self-Operated Control Valve
The Model 92C Self-Operated Valve is a cost-effective pressure reducer for use in steam applications. The valve can be equipped with a Model 6392 pilot or without a pilot for use as a pressure-loaded regulator. The commander-acting version uses the inlet pressure as the working medium; No need for a separate air ...
|
|
Fisher/Fisher V260 Control Valve
The Fisher V260 is a full-bore control valve with a bottom-up design that maximizes pressure, flow, and process control. Integral borehole silencers are used to control noise and vibration generated by high-pressure drop liquids and gases. The spline shaft is connected with the actuator, which reduces the movement loss. ...
|
|
Fisher/Fisher 4660 Pneumatic High and Low Pressure Conductor
The Fisher 4660 pneumatic pilot-operated pressure controller activates a safe shutdown system for flowlines, production vessels, and compressors. The pilot is available in single or dual setpoint capability models that use a switching point to maintain full output pressure when the process pressure is within the set point range. If the process ...
|
|
Fisher/Fisher Series 44-1300 Regulators
The 44-1300 Series is a high-pressure, high-flow pressure reducing valve that offers both bleed and balanced spool designs. The 44-1300 series is available with Cv = 0.8 and 2.0. Chamber-loaded and pneumatically compressed load models are available. Ideal for commercial diving, breathing air, special gas mixture regulation, rigid kit diving...
|
|
Fisher/Fisher 3582I Valve Positioner
Flexible module design – The 3582 Series units can be upgraded to the Model 3582i Electro-Pneumatic Positioner in the field to replace the measurement module with the Model 582i Electro-Ptic Converter Assembly (1). The Type 582i electric-gas converter is attached to the housing of the positioner and provides a very economical ...
|
|
Fisher/Fisher POSI-SEAL A11 rotary control butterfly valve
A control valve is a valve that is fully or partially opened or closed in a pipeline according to the process signal to control the flow, pressure, temperature and liquid level. Information on Fisher®, Baumann™ and POSI-SEAL™ brand control valves can be found via the links on this page.
...
|
|
Fisher/Fisher V270 Full Bore Ball Control Valve
The Fisher V270 is a three-piece, full-bore control valve fitted with a bottom shaft designed from the bottom up to optimize pressure, flow, and process control. The V270 full-bore ball valve provides automated control in bypass, batch application, monitor, and emergency shut-off valve applications with virtually no ...
|
|
Fisher/Fisher 1052 Rotary Actuator
The Fisher 1052 spring-return diaphragm rotary actuator operates a splined shaft rotary valve for on/off or throttling applications. The easy-to-install design offers a wide range of options: limit switches, position indicator switches, positioners, and manual overrides.
specification
Actuation method Spring back ...
|
|
Fisher/Fisher GX Control Valve Valve size standard NPS
Introduction: Fisher/Fisher GX control valve and actuator systems are designed with state-of-the-art technology in a small form factor for a wide range of process gases, vapors, and fluids, and are rugged, reliable, and user-friendly. It does not need to adjust the size of the actuator, once the valve ...
|
|
Fisher/Fisher OSE Quick Release Valve Remote alarm function
Introduction: The Fisher/Fisher OSE quick shut-off valve quickly shuts off the airflow in the event of overpressure or loss of pressure. It is ideal for applications that require complete cut-off protection, precise sealing, fast response, high impact and shock resistant gases, top-mounted design, easy in-line maintenance, and savings.
|
|
Fisher/Fisher A11 High Performance Butterfly Valve Stem Dynamic Loading
Introduction: The Fisher/Fisher A11 High Performance Butterfly Valve is a reliable, high-performance butterfly valve for throttling and switching applications. Available in a pair of clamp or single flange designs to maintain tight shut-off over long periods of time, the valve is specific for a wide range of pressure and temperature conditions, including cryogenic applications.
|
|
Fisher/Fisher DST-G trims
Fisher DST-G trims are designed for clean or dirty applications where dissolved gases are released from solution when pressure drops (outgassing). Outgassing typically causes two types of damage: cavitation and erosion of the fluid stream. The DST-G trim has a graded pressure drop, similar to the DST trim, to prevent ...
|
|
Fisher/Fisher R622, R642 and R652 Series Secondary Regulators - LP - Gas
The R600 series secondary regulators are UL listed for use to reduce the outlet pressure of primary regulators in residential installations. The R622 model is designed for use in residential installations with two-stage pressure regulation and can reach a maximum flow rate of 1 400 000 BTU / 15.8 SCMH per hour. Model R622 contains a high-performance pressure relief valve and ...
|
|
Fisher/Fisher Model SR5 Sanitary Pressure Regulator
The Fisher Model SR5 Regulator is a compact, high-flow, self-acting pressure reducer. It is designed for applications where hygienic design is extremely important, such as in the pharmaceutical, biotechnology or food and beverage industries. The unit is available in body sizes NPS 1/2 to 3 / DN 15 to 80 as well as ...
|
|
Fisher/Fisher Whisper Trim I Valve Cage™
The Fisher Whisper Trim I cage provides control of aerodynamic noise, especially in water, gas, or steam flow applications. The Whisper Trim I valve cage utilizes multiple specially shaped, dimensional, and spaced orifice to remove the noise generated by the water, gas, or steam flowing through the control valve.
|
|
Fisher/Fisher DMA Mechanical Atomizing Desuperheater
The Fisher DMA Desuperheater is a simple, mechanically atomized desuperheater with one or more nozzles with a fixed geometry for load-stabilized applications. The DMA is flanged to the side of the pipe in size DN 150 (NPS 6) or larger.
specification
Certified PED, CRN
...
|
|
Fisher/Fisher Model 252 filter
The Model 252 filter is designed to clean supply gas or air in a pilot, pneumatic instrument, or other device that requires clean gas to function properly when it is about to enter a pilot-acting regulator. This is an extended version of the filter with a larger drainage chamber that can hold more moisture and ...
|
|