Fisher/Fisher Type B Pressure Regulator Internal Pressure

Create Date: 2024-8-30 12:03:23|Source: Fisher

  • Brand:
    Fisher
    Origin:
    United States
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    Type B pressure reducer
    Product Introduction
    Fisher/Fisher Type B Pressure Regulator Inlet: Spherical quadratic curve or flat joint connection outlet: Flat gauge joint connection
Product Description
Introduction: Fisher/Fisher Type B Regulator Direct-acting, spring-loaded regulators provide economical pressure reduction control in a variety of residential, commercial, and industrial applications, as well as a wide range of vaporized fluids. This compact regulator can be installed in a ground-level pressure reducing cabinet, a pressure reducing and metering cabinet, or an underground module.
Fisher/Fisher Type B Pressure Regulator Internal Pressure
       Features:

Integrated quick shut-off valve

Compact design

Internal pressure reducing valve

Constant output pressure: two-stage decompression

Inlet strainer

Product parameters

Optional configuration B25: Regulator min. inlet pressure 50 mbar

B40: Regulator minimum inlet pressure 70 mbar

B50: Contains a battery with two B25 regulators

BCH 30: Regulator minimum inlet pressure 80 mbar

Body size DN20 x 32 | NPS 3/4 x 1-1/4

End connection inlet: spherical quadratic curve or plane joint connection

Outlet: Flat gauge connector connection

Inlet pressureMaximum inlet pressure: 4,0 bar | 58 psig

Inlet pressure range: 0,50 to 4,0 bar | 7,3 to 58 psig

Outlet pressureMaximum outlet pressure: 400 mbar | 161-inches w.c.

Pressure extraction method: internal pressure

Temperature range - 30° to 60°C | -200° to 140°F

This article introduces Fisher/Fisher Type B pressure reducer products, if you are interested in Fisher/Fisher pressure reducer, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.

Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only by being professional and careful in every process, every action and every detail of the service can we meet or even exceed customer expectations and make customers satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy. Safety relay products, if you are interested in Fisher/Fisher pressure reducer, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.

More on that
Fisher/Fisher CSB700 Pressure Reducing Regulator Overvoltage Protection Fisher/Fisher CSB700 Pressure Reducing Regulator Overvoltage Protection

Description: The Fisher CSB700 Pressure Reducing Regulator Direct Acting Spring-Loaded Regulator is designed for a wide range of pressure reduction applications. The regulator offers a great deal of flexibility because it offers a variety of body sizes and end connections, outlet pressure settings, and ...

Fisher/Fisher D4 Control Valve Flanged Fisher/Fisher D4 Control Valve Flanged

Introduction: The Fisher/Fisher D4 Control Valve is a compact, rugged straight-through valve designed primarily for high-pressure throttling applications, with pneumatic or electric control. This valve is best suited for pressure and flow control applications in the oil and gas production industry. These valves are particularly suitable for ...

Fisher/Fisher EZH and EZHSO series Fisher/Fisher EZH and EZHSO series

The EZH (Spring Closed) and EZHSO (Spring Open) series regulators are precision-piloted, pressure-balanced soft-seat regulators. These regulators are used for high-pressure natural gas transmission/city gate stations, high-flow distribution systems, and power plant gas supply. They have the ability to run smoothly and ...

Fisher/Fisher Model ACE95 Steam Storage Tank Seal Valve Fisher/Fisher Model ACE95 Steam Storage Tank Seal Valve

The Model ACE95 is a pilot-acting steam storage tank seal valve for precise pressure control in low-pressure sealing systems. Constructed of stainless steel, the unit is actuated by a large diaphragm actuator that accurately controls the seal pressure with a single adjustment bolt. peculiarity Fully balanced and non-motorized ...

Fisher/Fisher 1051 and 1052 Pneumatic Rotary Actuators Fisher/Fisher 1051 and 1052 Pneumatic Rotary Actuators

Product Description: Type 1051 and Type 1052 diaphragm rotary actuators are pneumatic spring-return actuators suitable for rotary control valves and other equipment. The Type 1051 actuator can be used for switching or throttling operations when equipped with a valve positioner. Type 1052 Actuator with or without Valve ...

Fisher/Fisher Model 92C Self-Operated Control Valve Fisher/Fisher Model 92C Self-Operated Control Valve

The Model 92C Self-Operated Valve is a cost-effective pressure reducer for use in steam applications. The valve can be equipped with a Model 6392 pilot or without a pilot for use as a pressure-loaded regulator. The commander-acting version uses the inlet pressure as the working medium; No need for a separate air ...

Fisher/Fisher T205 Series Tank Seal Regulators Fisher/Fisher T205 Series Tank Seal Regulators

The T205 series tank hermetic pressure regulator is a direct-acting spring pressure regulator. The T205 series can maintain a small positive pressure to prevent the vapors of the stored liquid from escaping into the atmosphere, reducing the risk of liquid combustion and preventing the product from being exposed to the air as much as possible.

Fisher/Fisher DVC6200P PROFIBUS PA Digital Valve Positioner Fisher/Fisher DVC6200P PROFIBUS PA Digital Valve Positioner

The Fisher® FIELDVUE™ DVC6200p Digital Valve Controller is a PROFIBUS PA communication protocol with connectionless, non-contact valve position feedback. In addition to the traditional function of converting digital signals into pneumatic outputs, PROFIBUS PA communication ...

Fisher/Fisher Series 634 High Pressure Shut-off Valves Fisher/Fisher Series 634 High Pressure Shut-off Valves

Fisher Models 634 and 634M high-pressure shut-off valves provide overpressure protection through isolation. The Model 634 internal take-off shut-off valve can be installed between a pressure reducing regulator and downstream systems or equipment. The Model 634M external pressure take-off valve requires a control line and is installed upstream of the pressure reducing regulator. peculiarity ...

Fisher 3582 Pneumatic, Single-Acting Positioner Fisher 3582 Pneumatic, Single-Acting Positioner

The Fisher 3582 Pneumatic Valve Positioner is used in conjunction with a diaphragm-actuated linear control valve assembly. This pneumatic valve positioner receives a pneumatic input signal from the control device, then regulates the air source pressure of the control valve actuator and provides an accurate valve stem position, which is the same as the pneumatic input ...

Fisher/Fisher 1077 Manual Handwheel Actuator Fisher/Fisher 1077 Manual Handwheel Actuator

Locking it by adjusting the stroke limiter provides accurate disc and ball positioning in both the closed position (0 degrees) and the open position (90 degrees). For 60-degree operation, a stroke limiter can be used to establish a valve disc or ball closure stop at any angle between 0 and 30 degrees.

Fisher/Fisher 656 Direct-Acting Diaphragm Actuator Fisher/Fisher 656 Direct-Acting Diaphragm Actuator

The Fisher 656 diaphragm actuator provides low- to medium-thrust actuation for stent-mounted applications. Such applications include the operation of butterfly valves and built-in turbine valves, louvers, dampers, and other similar equipment. specification Actuation mode: spring return, linear Certified PED, CUTR, ATEX Control...

Fisher/Fisher Model VS100 shut-off valve High flow valve body Fisher/Fisher Model VS100 shut-off valve High flow valve body

Introduction: The Fisher/Fisher Model VS100 shut-off valve is designed to shut off the airflow to the downstream system when the outlet pressure exceeds a predetermined range. The body of the VS100 valve contains a movable valve bore in the bonnet and a shut-off valve called VSX4.   Features: ...

Fisher/Fisher 25 VenTemp desuperheater Fisher/Fisher 25 VenTemp desuperheater

The Fisher Yarway 25 VenTemp desuperheater is primarily used in low-volume superheated steam systems with fairly constant loads. The design provides a simple, cost-effective method of steam temperature control. specification Critical maintenance steam conditions The flow characteristics are linear Materials: 304 stainless steel, 316 ...

Fisher/Fisher Y602 Series Ventilation Components Fisher/Fisher Y602 Series Ventilation Components

Y602 Series ventilation assemblies help prevent vent obstruction and ensure proper air or gas flow in regulator spring housings, remote ventilation ducts, actuator membrane housings, and other applications. These ventilation components are available in angled or straight-through versions. In general, angular ventilation components protect the side ...

Fisher/Fisher DMA/AF-HTC desuperheater Fisher/Fisher DMA/AF-HTC desuperheater

The DMA/AF-HTC is functionally identical to the DMA/AF, but its construction is suitable for more demanding applications. The most common applications include interstage tempering of boilers, where desuperheaters are exposed to vibrations caused by high thermal cycling and pressure, high steam velocity, and flow. In addition to this specific application ...

Fisher/Fisher D3 FloPro Control Valve Fisher/Fisher D3 FloPro Control Valve

The Fisher D3 Control Valve is a compact, rugged valve for on/off or throttle control with FloPro technology and the choice of pneumatic or electric control. This valve is best used as a tipping valve for gas separators and scrubbers. At the same time ...

Fisher/Fisher Model MR105 Direct-Acting Vacuum Liquid Regulator Fisher/Fisher Model MR105 Direct-Acting Vacuum Liquid Regulator

The Model MR105 Direct Acting Pressure Reducing Regulator is a high-flow, multi-purpose regulator designed to provide fast and economical pressure control for a wide range of applications with different fluid media such as liquids, air, and gases. The MR105 valve is the most important for response speed.

Fisher/Fisher HP Series Control Valves Fisher/Fisher HP Series Control Valves

The Fisher HP Series Control Valve is a single-port, high-pressure, globe or angle valve with a metal seat, cage guide, and push-down to shut-off plug action. These valves are designed for high-pressure applications in the process control industry, such as power generation, hydrocarbon production, chemical processing, and oil refining. ...

Fisher/Fisher HVP polymer flow control Fisher/Fisher HVP polymer flow control

Fisher's High Viscosity Polymer (HVP) series of control valves are widely used in the polymer industry. These processes often require valves to operate at sustained high temperatures to ensure the free flow of polymer fluids. The HVP valve provides a one-piece body with a heat transfer fluid pumped out, continuously providing ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top