Fisher/Fisher Series 634 High Pressure Shut-off Valves

Create Date: 2024-8-30 12:03:23|Source: Fisher

  • Brand:
    Fisher
    Origin:
    United States
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    Series 634 High Pressure Shut-off Valves
    Product Introduction
    Overvoltage protection eliminates the need for exhaust gases
Product Description
Fisher Models 634 and 634M high-pressure shut-off valves provide overpressure protection through isolation. The Model 634 internal take-off shut-off valve can be installed between a pressure reducing regulator and downstream systems or equipment. The Model 634M external pressure take-off valve requires a control line and is installed upstream of the pressure reducing regulator.
Fisher/Fisher Series 634 High Pressure Shut-off Valves
peculiarity

Overvoltage protection eliminates the need for exhaust gases

Forward turn-off

Diverse applications

Easy to maintain

specification

Body size and face connection 3/4 or 1 NPT

Maximum inlet pressure 1500 psig / 103 bar

Maximum Outlet (Housing) Pressure Model 634: 150 psig / 10.3 bar

Model 634M: 1500 psig / 103 bar

Pressure method 634 type: internal

Type 634M: External

Temperature range -40° to 180°F / -40° to 82°C

Approximate weight 10 lb / 4 kg

This article introduces the Fisher/Fisher 634 series high pressure shut-off valve products, if you are interested in Fisher/Fisher pressure regulators, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.

The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!

More on that
Fisher/Fisher 377 Pressure Sensitive Guard Valve Fisher/Fisher 377 Pressure Sensitive Guard Valve

The Fisher 377 guard valve assists in maintaining routine process operations that require a specific valve or actuator. When the compressed air pressure drops below the trigger point, the guard valve prevents the actuator from rising, locking in the previous position, or not descending. When the compressed air pressure rises above the trigger point, 3 ...

Fisher/Fisher Model 63EG-98HM Pilot-Acting Pressure Relief Valve or Back-Pressure Regulator Fisher/Fisher Model 63EG-98HM Pilot-Acting Pressure Relief Valve or Back-Pressure Regulator

The 63EG-98HM can be used in gas, liquid, or vapor applications. Suitable for applications up to 550°F / 288°C, Model 63EG-98HM utilizes high-temperature ethylene propylene diene diene monomer (EPDM) or perfluoroelastomer (FFKM) to provide Class VI shut-off. If used in corrosive conditions, the ...

Fisher/Fisher Model VS100 shut-off valve High flow valve body Fisher/Fisher Model VS100 shut-off valve High flow valve body

Introduction: The Fisher/Fisher Model VS100 shut-off valve is designed to shut off the airflow to the downstream system when the outlet pressure exceeds a predetermined range. The body of the VS100 valve contains a movable valve bore in the bonnet and a shut-off valve called VSX4.   Features: ...

Fisher/Fisher Series 44-1300 Regulators Fisher/Fisher Series 44-1300 Regulators

The 44-1300 Series is a high-pressure, high-flow pressure reducing valve that offers both bleed and balanced spool designs. The 44-1300 series is available with Cv = 0.8 and 2.0. Chamber-loaded and pneumatically compressed load models are available. Ideal for commercial diving, breathing air, special gas mixture regulation, rigid kit diving...

Fisher/Fisher 4660 Pneumatic High and Low Pressure Conductor Fisher/Fisher 4660 Pneumatic High and Low Pressure Conductor

The Fisher 4660 pneumatic pilot-operated pressure controller activates a safe shutdown system for flowlines, production vessels, and compressors. The pilot is available in single or dual setpoint capability models that use a switching point to maintain full output pressure when the process pressure is within the set point range. If the process ...

Fisher/Fisher C1 Pneumatic Controllers & Converters Fisher/Fisher C1 Pneumatic Controllers & Converters

The Fisher C1 controller and transmitter continues the tradition of durable and reliable manometry equipment when it comes to solving air/gas consumption problems. The C1 meets the needs of durable and reliable pressure measurement equipment. specification Certified ATEX, CUTR Input signal pneumatic Maximum outlet pressure 40 p ...

Fisher/Fisher HVP polymer flow control Fisher/Fisher HVP polymer flow control

Fisher's High Viscosity Polymer (HVP) series of control valves are widely used in the polymer industry. These processes often require valves to operate at sustained high temperatures to ensure the free flow of polymer fluids. The HVP valve provides a one-piece body with a heat transfer fluid pumped out, continuously providing ...

Fisher/Fisher 67C Instrument Regulator Body material is optional Fisher/Fisher 67C Instrument Regulator Body material is optional

Introduction: Fisher/Fisher 67C Instrument Regulators Direct Acting Regulators and Filter Regulators are commonly used to deliver reduced, continuously controlled pressure to pneumatic and electropneumatic controllers and other instruments. These regulators are suitable for most air or gas applications. Other application packages ...

Fisher/Fisher Models 1808 and 1808A Pressure Relief Valves or Back Pressure Regulators Fisher/Fisher Models 1808 and 1808A Pressure Relief Valves or Back Pressure Regulators

Fisher's 1808 Spherical and 1808A Angle-Directed Back-Pressure Regulators or Relief Valves are economical and compact for use in gas or liquid applications to maintain pressure on oil-gas separators, or for pressure relief applications in gas distribution systems. peculiarity The design is simple and reliable Compact and lightweight Square...

Fisher 167D-2594-179127 Switching Valve 167DA Position Retention Valve Fisher 167D-2594-179127 Switching Valve 167DA Position Retention Valve

Fisher 167D-2594-179127 Switching Valve 167DA Retaining Valve The 167D Series Switching Valve is typically used to provide reduced, stable vaporized liquid pressure to pilot-acting controllers and other pneumatic instruments. Models 167D and 167DS valves are two-way switching valves. 167DA and 167DA ...

Fisher/Fisher Pressure Regulator Series 310A Fisher/Fisher Pressure Regulator Series 310A

Liquefied petroleum gas regulator Fisher LPG pressure regulators are used to compensate for fluctuating tank pressures and supply constant pressure of propane gas to furnaces, burners, appliances, farm faucets, commercial companies, and plants. natural gas Fisher's Natural Gas Pressure Control Products ...

Fisher/Fisher H120 Series Pressure Relief Valves Fisher/Fisher H120 Series Pressure Relief Valves

The Fisher Model H120 direct-acting pressure relief valve comes with a pre-installed fixed spring retaining ring. The inlet pressure taker is mounted directly to the spring load lift assembly with a nitrile rubber (NBR) disc. When the inlet pressure exceeds the spring set value, the lifting assembly and disc assembly will be pushed ...

Fisher/Fisher V250 Control Valve Features linear Fisher/Fisher V250 Control Valve Features linear

Introduction: The Fisher/Fisher V250 control valve has a hemispherical construction valve with a specially designed corrugated V-notch. The Vee-Ball Control Valve combines the ruggedness of a linear valve with the high efficiency of a rotary valve, and the shear action between the V-notch ball core and the spherical seal improves the valve's ...

Fisher/Fisher Models 1301F and 1301G High Voltage Regulators Fisher/Fisher Models 1301F and 1301G High Voltage Regulators

Models 1301F and 1301G are self-acting, high-pressure regulators that can be used in applications where the pressure of high-pressure gases must be reduced, used as a pilot supply pressure in a pilot-acting regulator, or as a load pressure in a pressure-loaded regulator. The Model 1301F and 1301G regulators are also ...

Fisher/Fisher 4195K Gauge Pressure Indicator Controller Fisher/Fisher 4195K Gauge Pressure Indicator Controller

The Fisher 4195K Gauge Pressure Indicator Controller displays process pressure and set point values on an easy-to-read process dial. These controllers compare the process pressure to the operator's adjusted set point and provide a pneumatic signal to the control element to change the process pressure toward the set point. ...

Fisher/Fisher Valves Series 167D Switching Valves Fisher/Fisher Valves Series 167D Switching Valves

The Series 167D Switching Valve is used to provide reduced, stable vaporized liquid pressure to pilot-acting controllers and other pneumatic instruments. Models 167D and 167DS valves are two-way switching valves. Models 167DA and 167DAS are three-way switching valves. peculiarity Compact Easy*** adjustment ...

Fisher/Fisher 1051 and 1052 Pneumatic Rotary Actuators Fisher/Fisher 1051 and 1052 Pneumatic Rotary Actuators

Product Description: Type 1051 and Type 1052 diaphragm rotary actuators are pneumatic spring-return actuators suitable for rotary control valves and other equipment. The Type 1051 actuator can be used for switching or throttling operations when equipped with a valve positioner. Type 1052 Actuator with or without Valve ...

Fisher/Fisher Model 146 Severe Service Feed Valve Fisher/Fisher Model 146 Severe Service Feed Valve

Severe service valves for water applications in the power industry Feed Water Control Valve/Start Feed Water Regulator/Boiler Circulation Valve peculiarity Forged body Angular or Z-shaped Self-sealing lid Resistant to cavitation and flash evaporation Low noise The separation of sealing and control is realized Actuation: hydraulic, pneumatic, electric specification ...

Fisher/Fisher 8560 High Performance Butterfly Valve Standard valve Fisher/Fisher 8560 High Performance Butterfly Valve Standard valve

Introduction: The Fisher/Fisher 8560 High Performance Butterfly Valve Eccentricity Mounted Butterfly Plate Design provides near-linear flow characteristics; The butterfly plate rotates by 90 degrees and is suitable for switching or throttling control applications.   Features: Trim and bolt materials are suitable for acidic applications. ...

Fisher/Fisher FieldQ VOS Valve Operating System (VOS) and rack and pinion actuators Fisher/Fisher FieldQ VOS Valve Operating System (VOS) and rack and pinion actuators

Turnkey valve operating system with pneumatic rack and pinion actuators, controls and mounting brackets. Function: Turnkey all-in-one actuator with control and mounting device specification Power source: Pneumatic Product Type: Pneumatic Actuator Actuation Valve ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top