Introduction: Fisher/Fisher GX control valve and actuator systems are designed with state-of-the-art technology in a small form factor for a wide range of process gases, vapors, and fluids, and are rugged, reliable, and user-friendly. It does not require the size of the actuator to be adjusted, and once the structure of the valve body has been selected, the actuator can be selected automatically, in accordance with EN and ANSI standards, and a complete accessory package is available for purchase, including DVC2000 integrated digital valves.
Features:
Locators
Easily determine specifications and choices.
There is no need to determine the actuator specifications; The selection of specifications is done automatically.
The actuator is optimized for a wide range of compressed air conditions.
Well-designed for easy maintenance.
Trim is replaceable.
Low cost of use.
Rugged, miniaturized design
Product parameters
Certifications: CRN, CUTR, Fugitive Emissions, PED, SIL Compliant
Critical Conditions: Noise Suppression, Cavitation, Aggressive, Low Flow, Corrosive, General Condition
Flow characteristics: balanced percentage, linear, characterized
Materials: carbon steel, stainless steel, double-sided, alloy
Operating temperature: standard temperature, high temperature
Pressure ratings: CL150, CL 300, PN 10/16, PN 10/16/25/40, PN 25/40
Process connector type: flanged type
Cut-off class: Class IV (FCI 70-2), Class V (FCI 70-2), Class VI (FCI 70-2)
Valve sizes: NPS 1/2, NPS 3/4, NPS 1, NPS 1-1/2, NPS 2, NPS 3, NPS 4, NPS 6
Valve size standard: NPS
This article introduces Fisher/Fisher GX control valve products, if you are interested in Fisher/Fisher control valves, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only by being professional and careful in every process, every action and every detail of the service can we meet or even exceed customer expectations and make customers satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy. Safety relay products, if you are rightFisher/Fisher control valvesIf you are interested, please also contact our customer service, we look forward to your call, and hope that our technology and service can bring you a better experience.
|
More on that
|
Fisher/Fisher 627 Series Commercial/Industrial Regulators
Fisher's 627 Series direct-acting pressure reducers are suitable for use in both low- and high-pressure systems. These regulators can be used with natural gas, air, or a variety of other gases. Performance characteristics vary according to the structure.
peculiarity
Internal pressure relief valve
Model 627R and 627MR stroke limiters
Discharge Operation Indicator ...
|
|
Fisher/Fisher M Series Handwheel Turbine Actuators
The Fisher M-Series Hand Turbine Actuator is a fully enclosed, all-weather turbine actuator that provides reliable manual operation for the Fisher A11, A31A, and A41 high-performance butterfly valves.
The Fisher M Series Hand Turbine Actuator consists of a body shell, cover, turbine, ...
|
|
Fisher/Fisher V270 Full Bore Ball Control Valve
The Fisher V270 is a three-piece, full-bore control valve fitted with a bottom shaft designed from the bottom up to optimize pressure, flow, and process control. The V270 full-bore ball valve provides automated control in bypass, batch application, monitor, and emergency shut-off valve applications with virtually no ...
|
|
Fisher/Fisher Model EZR Pressure Relief Valve or Back Pressure Regulator
Fisher's Model EZR Pilot Operated Pressure Relief Valve or Back Pressure Regulator is commonly used as an overpressure protection relief valve in city gate and district stations, or as a back pressure regulator in commercial and industrial applications. Its quiet and smooth operation, tight shut-off and long service life, even in dirty conditions...
|
|
Fisher/Fisher WhisperFlo Pneumatic Noise Cancelling Internals
Designed for applications that require superior noise reduction, Fisher WhisperFlo trims represent the most advanced solutions available. Control valves with WhisperFlo trims provide additional suppression of pneumatic noise in the harshest high-pressure precipitation or gas applications. With phase ...
|
|
Fisher/Fisher 3582I Valve Positioner
Flexible module design – The 3582 Series units can be upgraded to the Model 3582i Electro-Pneumatic Positioner in the field to replace the measurement module with the Model 582i Electro-Ptic Converter Assembly (1). The Type 582i electric-gas converter is attached to the housing of the positioner and provides a very economical ...
|
|
Fisher/Fisher R222 Series Secondary Regulators
The R222 series regulators are certified by Underwriters Laboratories (United States Safety Testing Laboratories, Inc.) for use in LPG two-stage pressure regulating systems. The unit reduces the outlet pressure of the primary regulator (typically from 10 psig / 0.69 bar) to 11-in ...
|
|
Fisher/Fisher Series 912 Pressure Reducing Regulator - LPG
The Series 912 direct-acting, spring-loaded regulators are United States Safety Testing Laboratories Corporation (UL) certified regulators for use in a variety of applications and industrial applications. The valve membrane of these regulators has some internal pressure relief to help minimize overpressure.
peculiarity
...
|
|
Fisher/Fisher HVP polymer flow control
Fisher's High Viscosity Polymer (HVP) series of control valves are widely used in the polymer industry. These processes often require valves to operate at sustained high temperatures to ensure the free flow of polymer fluids. The HVP valve provides a one-piece body with a heat transfer fluid pumped out, continuously providing ...
|
|
Fisher/Fisher TBX-T desuperheater
The Fisher TBX-T desuperheater can be used in a variety of applications to effectively reduce the temperature of superheated steam to the ideal set point. The TBX-T can be installed in steam lines with diameters DN 200 to DN 1200 (NPS 8 to 48) and can maintain steam temperatures at 6°C (10° ...
|
|
Fisher/Fisher DMA Mechanical Atomizing Desuperheater
The Fisher DMA Desuperheater is a simple, mechanically atomized desuperheater with one or more nozzles with a fixed geometry for load-stabilized applications. The DMA is flanged to the side of the pipe in size DN 150 (NPS 6) or larger.
specification
Certified PED, CRN
...
|
|
Fisher/Fisher Whisper Trim I Valve Cage™
The Fisher Whisper Trim I cage provides control of aerodynamic noise, especially in water, gas, or steam flow applications. The Whisper Trim I valve cage utilizes multiple specially shaped, dimensional, and spaced orifice to remove the noise generated by the water, gas, or steam flowing through the control valve.
|
|
Fisher/Fisher NotchFlo™ DST Control Valve Prevents cavitation
Introduction: Fisher/Fisher NotchFlo™ DST control valves are designed for use in dirty, cavitation applications. The trims in this valve utilize a range of flow restrictions and extensions to eliminate cavitation, allowing particles up to 12.7 mm (1/2 in) in diameter to pass through without clogging.
...
|
|
Fisher/Fisher dirty service trims
Fisher dirt service trims are designed for dirt and cavitation applications. Cavitation is eliminated with a range of flow limits and extensions, allowing particles up to 19mm (3/4in) in diameter to pass through without clogging. Each trim stage has a sequentially increasing flow ...
|
|
Fisher/Fisher 4660 Pneumatic Pilot Operated Pressure Controller
N05500 nickel alloy Boton tubes are also available for applications where the controller must meet the NACE MR0175-2002N05500 standard.
Repeatability conforms to the Outer Rim of the Continental Shelf (OCS) Order 5 for United States Bureau of Minerals test deviations and the standards defined in the United States Petroleum Organization (API) RP14C.
|
|
Fisher/Fisher YD and YS 3-Way Cage Pilot Valves Socket welded connections
Introduction: Fisher/Fisher YD and YS 3-way cage pilot valves are designed for throttling or on/off service and are available in balanced and unbalanced configurations. YD valves are used in general merging and diverting applications. YS valves are used in general merging applications. Fisher YD and YS valves are used in a wide range of applications, including oil ...
|
|
Fisher/Fisher easy-e ET control valves
The Fisher easy-e ET is the ideal solution for all high process temperature general applications, with a balanced plug design and cage guided trims. Available with straight-through or angled bodies, these valves provide up to Class V or Level VI shut-off
specification
Certified to SIL, fugitive emissions, N...
|
|
Fisher/Fisher Model 92C Self-Operated Control Valve
The Model 92C Self-Operated Valve is a cost-effective pressure reducer for use in steam applications. The valve can be equipped with a Model 6392 pilot or without a pilot for use as a pressure-loaded regulator. The commander-acting version uses the inlet pressure as the working medium; No need for a separate air ...
|
|
Fisher/Fisher 1301 regulator
The 1301 series is a high-pressure pressure regulator used to supply air to instruments. It is equipped with a pressure gauge interface and can be equipped with a pressure gauge as an option.
Connection size: NPS 1/4
Regulated pressure range: .0.69 to 34.5 bar/10 to 500 psig
Maximum inlet pressure: 414bar/6000psig
This article describes the fee ...
|
|
Fisher/Fisher FB Welded Angle Valve PEEK Drop Resistant
Introduction: Fisher/Fisher FB welded angle valves control compressible fluids and can be used in special applications that require maximum noise reduction and high flow capacity. Typical applications include main steam pressure reducing valves and compressor bypass valves. FB valves are also commonly used in petrochemical and natural gas processing plants for acidic ...
|
|