Product Description
The Fisher TBX-T desuperheater can be used in a variety of applications to effectively reduce the temperature of superheated steam to the ideal set point. The TBX-T can be installed in steam lines with diameters DN 200 to DN 1200 (NPS 8 to 48) and can maintain steam temperatures within a saturation temperature range of 6°C (10°F). In all steam conditioning applications, the atomization and vaporization of water is a key element. The TBX-T design combines nozzle headers for multiple forms of AF nozzles to produce optimal spray patterns over a wide operating range. These suitable nozzles were selected for optimal mixing and rapid vaporization under all flow conditions.
Fisher/Fisher TBX-T desuperheater
Certified PED, CRN

Severe service steam conditioning

Materials SA105, F22, F91

The operating temperature is high

Stress Rating ASME

Process connector type: flange, butt welding, RTJ, socket welding

Valve sizes NPS 8 to 48

Valve size standard NPS

For other configurations, contact your local Emerson business partner or sales office for more information on technical specifications or options for this product.

peculiarity

CFD-designed nozzle headers determine the spray point and insertion depth for maximum mixing and rapid vaporization.

The TBX-T offers options including an integrated insulation lining inside the steam pipe. This construction is most commonly used in boiler interstage temperature control applications, where the desuperheater is exposed to vibrations caused by high thermal cycling and pressure, high steam velocity, and flow. When introducing cold water to equipment that has been heated to operating steam temperatures, the lining minimizes the chance of thermal shock.

The TBX-T desuperheater combines a nozzle header for multiple forms of AF-type nozzles to produce optimal spray patterns over a wide operating range. These suitable nozzles were selected for optimal mixing and rapid vaporization under all flow conditions.

This article introduces Fisher/Fisher TBX-T desuperheater products, if you are interested in Fisher/Fisher pressure regulators, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.

The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!

More on that
Fisher Model 155 High Pressure Steam Pressure Reducing Valve Fisher Model 155 High Pressure Steam Pressure Reducing Valve

Low-noise steam pressure reducing valves controlled by multi-stage trim trims are used in boiler start-up and steam generation processes peculiarity Pressure-sealed bonnet. Low-maintenance gland filled with pure graphite (re-tightened). Polished stem. Hard-faced rails. Pressure-balanced spool. Hard-faced sealing surfaces. ...

Fisher 3610JP Pneumatic Double Acting Valve Positioner Fisher 3610JP Pneumatic Double Acting Valve Positioner

The Fisher 3610JP pneumatic positioner can be used with a double-acting rotary actuator to locate control valves used in throttling applications. These positioners are rugged and provide valve positioning proportional to the pneumatic input signal or DC current input signal and as a whole ...

Fisher/Fisher Model 1290 Vapor Recovery Regulator Fisher/Fisher Model 1290 Vapor Recovery Regulator

The Model 1290 Vapor Recovery Regulator is a self-contained commander-acting regulator system for vapor recovery of sealed gases. peculiarity Quick-change trim kits Easy to maintain online Trips can be monitored during use High precision The technology is mature specification Body size NPS 1 or 2 ...

Fisher/Fisher easy-e EZ control valve Fisher/Fisher easy-e EZ control valve

Fisher easy-e EZ control valves provide throttling or on-off solutions for chemical or hydrocarbon treatment applications, or any occasion where non-lubricated, viscous or otherwise difficult liquids need to be controlled. specification Certified to SIL, Fugitive Emissions, NACE Critical Noise Suppression ...

Fisher/Fisher 2052 Spring & Diaphragm Rotary Valve Fisher/Fisher 2052 Spring & Diaphragm Rotary Valve

The Fisher 2052's highly versatile features and compact actuator design assist with throttling or on/off applications. It can be installed on any valve, even when space is limited. specification Actuation method: spring return, quarter-angle rotation, rotation Certified PED compliant ...

Fisher/Fisher Model R222H Primary Regulator for LPG Fisher/Fisher Model R222H Primary Regulator for LPG

 Introduction: The Fisher/Fisher Model R222H is a one-stage regulator that offers 65% higher flow and 40% smaller volume than standard compact regulators for use in underground tanks or airchambers where space is limited. Approved by Underwriters Laboratories (UL) (United States Safety Testing Laboratories Inc. ...

Fisher/Fisher pipe silencer Fisher/Fisher pipe silencer

Complete Fisher pipe silencers provide superior noise reduction performance for applications where valves generate a lot of noise. Once installed, the total system pressure drop is split between the valve and the silencer. This allows the valve to operate at a lower pressure drop ratio, reducing the noise generated during the flow through the control valve.

Fisher/Fisher 3610J Pneumatic, Single-Acting Positioner Fisher/Fisher 3610J Pneumatic, Single-Acting Positioner

The Fisher 3610J pneumatic positioner can be used with a single-acting rotary actuator to precisely locate control valves used in throttling applications. These positioners are rugged and provide valve positioning proportional to the pneumatic input signal or DC current input signal and as a whole ...

Fisher/Fisher Sempell Model 151 Pressure Reducing Steam Valve Fisher/Fisher Sempell Model 151 Pressure Reducing Steam Valve

Sempell control valves for steam applications in the power industry peculiarity The valve can be easily removed The base is replaceable Low-maintenance gland filled with pure graphite PTFE collars up to 250°C/480°F Polished stem makes for less friction. The spacious body is also suitable for harsh operating conditions ...

Fisher/Fisher DST-G trims Fisher/Fisher DST-G trims

Fisher DST-G trims are designed for clean or dirty applications where dissolved gases are released from solution when pressure drops (outgassing). Outgassing typically causes two types of damage: cavitation and erosion of the fluid stream. The DST-G trim has a graded pressure drop, similar to the DST trim, to prevent ...

Fisher/Fisher 1305 Series Pressure Reducing Regulator Direct Acting Formula Fisher/Fisher 1305 Series Pressure Reducing Regulator Direct Acting Formula

Introduction: The 1305 series regulator is a direct-acting pressure reducing regulator that avoids hydrate formation and regulator freezing, and is typically used on high-pressure lines at wellheads and isolators. These regulators are suitable for natural gas, air, propane, and other gas applications.   Features: ...

Fisher/Fisher Split Valve Positioner DVC6205 DVC6215 Fisher/Fisher Split Valve Positioner DVC6205 DVC6215

Emerson introduces a remotely mountable digital valve controller specifically designed for harsh environments Emerson's Fisher® FIELDVUE™ DVC6205 DVC6215 discrete stroke sensing and control elements to help meet extreme temperature and vibration valve needs It has been proven that Emerson's Fisher...

Fisher/Fisher 585C piston actuator Fisher/Fisher 585C piston actuator

The Fisher 585C piston actuator provides low to medium thrust actuation for a variety of small to medium-sized Fisher slide rod valves, including easy-e™, HP, EH, and 461 valves. The double-acting design of the actuator produces a solid and precise positioning. The actuator's miniature ...

Fisher/Fisher 1301 regulator Fisher/Fisher 1301 regulator

The 1301 series is a high-pressure pressure regulator used to supply air to instruments. It is equipped with a pressure gauge interface and can be equipped with a pressure gauge as an option. Connection size: NPS 1/4 Regulated pressure range: .0.69 to 34.5 bar/10 to 500 psig Maximum inlet pressure: 414bar/6000psig This article describes the fee ...

Fisher/Fisher Pressure Regulator Series 310A Fisher/Fisher Pressure Regulator Series 310A

Liquefied petroleum gas regulator Fisher LPG pressure regulators are used to compensate for fluctuating tank pressures and supply constant pressure of propane gas to furnaces, burners, appliances, farm faucets, commercial companies, and plants. natural gas Fisher's Natural Gas Pressure Control Products ...

Fisher/Fisher 4320 Wireless Position Monitor Fisher/Fisher 4320 Wireless Position Monitor

The Fisher 4320 Wireless Position Monitor requires no wiring to connect to a pneumatically actuated on/off valve. It utilizes the percentage of range and on/off indication to indicate the device position with a precise wireless feedback signal. The 4320 can be used to control and/or monitor valves, linear pressure regulators, displacements, and floats.

Fisher/Fisher CS400 pressure reducer Fisher/Fisher CS400 pressure reducer

Fisher's CS400 Series direct-acting spring pressure regulators are designed to meet a wide range of pressure reduction applications in commercial and light industrial facilities. The regulator offers a great deal of flexibility because it is available in a variety of body sizes and end connections, outlet pressure settings, orifice sizes, and ...

Fisher/Fisher AV III Micro-Flat trims Fisher/Fisher AV III Micro-Flat trims

Fisher CAV III Micro-Flat trims are designed for cleaning, cavitation, and low flow applications with a maximum pressure drop of 241 bar (3500 psi). This product is a combination of two different products: cavitation control with Cavitrol III trims and Micro-Flat ...

Fisher/Fisher OSE Quick Release Valve Remote alarm function Fisher/Fisher OSE Quick Release Valve Remote alarm function

Introduction: The Fisher/Fisher OSE quick shut-off valve quickly shuts off the airflow in the event of overpressure or loss of pressure. It is ideal for applications that require complete cut-off protection, precise sealing, fast response, high impact and shock resistant gases, top-mounted design, easy in-line maintenance, and savings.

Fisher/Fisher Model 92C Self-Operated Control Valve Fisher/Fisher Model 92C Self-Operated Control Valve

The Model 92C Self-Operated Valve is a cost-effective pressure reducer for use in steam applications. The valve can be equipped with a Model 6392 pilot or without a pilot for use as a pressure-loaded regulator. The commander-acting version uses the inlet pressure as the working medium; No need for a separate air ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top