Introduction: Fisher/Fisher FB welded angle valves control compressible fluids and can be used in special applications that require maximum noise reduction and high flow capacity. Typical applications include main steam pressure reducing valves and compressor bypass valves. FB valves are also commonly used in sour gas applications in petrochemical and natural gas processing plants.
Features:
Whisper Trim™ III or WhisperFlo™ cages for FBD or FBT valves reduce noise from high flow rates and large pressure drops.
This design reduces gasket sealing problems caused by thermal expansion and contraction of long components, such as cage assemblies.
ENVIRO-SEAL™ OR HIGH-SEAL PACKING SYSTEMS ARE AVAILABLE. These packing systems offer excellent sealing, guiding and load-force transfer properties.
FBT valves feature spring-loaded seals with PEEK breakout rings for Class V shut-off up to 316°C (600°F). The FBD valve features Bore seal for Class V shut-off above 316°C (600°F).
Product parameters
Certifications: CURT, PED, CRN, Fugitive Emissions, NACE
Key services: noise suppression, steam conditioning, degassing
Flow characteristics: linear
Materials: carbon steel, stainless steel, double-sided, alloy, cast iron
Operating temperature: standard temperature, high temperature
Stress Rating: ASME
Process connector type: flange type, butt welding, RTJ
Cut-off class: Class II (FCI 70-2), Class III (FCI 70-2), Class IV (FCI 70-2), Class V (FCI 70-2)
Valve sizes: NPS 8, NPS 10, NPS 12, NPS 14, NPS 16, NPS 18, NPS 20, NPS 24, NPS 30, NPS 36
Valve size standard: NPS
This article introduces Fisher/Fisher FB welded angle valve products, if you are interested in Fisher/Fisher control valves, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only by being professional and careful in every process, every action and every detail of the service can we meet or even exceed customer expectations and make customers satisfied and recognize us. Honest, professional, affordable, and fast, so you can rest assured. "Honest and professional service, affordable price, continuous improvement" is our service philosophy. Safety relay products, if you are interested in Fisher/Fisher control valves, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Fisher/Fisher Model 1805P Pilot-Acting Pressure Relief Valve Spring Adjustable
Introduction: The Model 1805P-6358 Pressure Relief Valve is an accurate, low-cost commander-acting pressure relief valve consisting of a Model 1805P main valve and a Model 6358 commander. It is available in an NPS 2 size version with three ranges of 10 to 100 psig / 0.69 to 6.9 bar.
|
|
Fisher/Fisher 8560 High Performance Butterfly Valve with Metsonyland Positioner SVI3
Fisher Fisher Valve Instrument|The Fisher™ 8560 High Performance Butterfly Valve is equipped with Metsonyland positioner SVI3
A butterfly valve is a type of rotary valve that uses a rotating disc to control the flow of pipes. The disc is typically operable at 90 degrees and provides linear flow characteristics. For throttle control applications, one type of butterfly valve ...
|
|
Fisher/Fisher DSA Vapor Regulated Desuperheater Pressure Rating ASME
Introduction: The Fisher/Fisher DSA steam conditioning desuperheater uses high-pressure steam to rapidly and thoroughly atomize water jets in a low-flow steam line. The desuperheater is flanged to a pipe with DN 200 (NPS 8) or larger. This desuperheater is suitable for applications that require a high turndown ratio.
...
|
|
Fisher/Fisher FIELDVU DVC6200f Digital Valve Controller
The performance and simplicity of the Fisher FIELDVUE DVC2000 meter allows you to operate closer to the set point, improving product quality with more accurate control. WITH FIELDVUE PERFORMANCE DIAGNOSTICS, VALVE OPERATION WILL BE MONITORED ONLINE 24/7 TO ASSESS PERFORMANCE AND RELIABILITY.
|
|
Fisher/Fisher GX Control Valve & Actuator System - GX 3-Way Valve
Fisher's GX valve and actuator systems meet a wide range of flow and line options. Optional tee structure for precise temperature control. The channels designed inside the body provide the best possible capability to create a stable flow pattern for smooth operation.
Emerson Fisher Valve ...
|
|
Fisher/Fisher Vee-Ball™ V150E Control Valve
The Fisher V150E Vee-Ball Control Valve features a flanged enlarged outlet design. The outlet flange has a standard pipe size diameter that is larger than the inlet diameter. The streamlined structure of the expanded outlet geometry helps the liquid flow smoothly through the valve as the flow area from the inlet to the outlet increases. ...
|
|
Fisher/Fisher AV III Micro-Flat trims
Fisher CAV III Micro-Flat trims are designed for cleaning, cavitation, and low flow applications with a maximum pressure drop of 241 bar (3500 psi). This product is a combination of two different products: cavitation control with Cavitrol III trims and Micro-Flat ...
|
|
Fisher/Fisher Model EZR Pressure Relief Valve or Back Pressure Regulator
Fisher's Model EZR Pilot Operated Pressure Relief Valve or Back Pressure Regulator is commonly used as an overpressure protection relief valve in city gate and district stations, or as a back pressure regulator in commercial and industrial applications. Its quiet and smooth operation, tight shut-off and long service life, even in dirty conditions...
|
|
Fisher/Fisher Split Valve Positioner DVC6205 DVC6215
Emerson introduces a remotely mountable digital valve controller specifically designed for harsh environments
Emerson's Fisher® FIELDVUE™ DVC6205 DVC6215 discrete stroke sensing and control elements to help meet extreme temperature and vibration valve needs
It has been proven that Emerson's Fisher...
|
|
Fisher/Fisher Control Valve - V150S-V-Ball Rotary Flange Control Valve
Fisher Control Valve V150S V-Ball Rotary Flange Control Valve, which uses rugged construction, highly abrasion-resistant trim materials, and unrestricted DC access, makes this valve ideal for controlling abrasive slurries. This design is particularly effective in reducing ...
|
|
Fisher/Fisher Micro-Flat cavitation valve trims
Fisher Micro-Flat cavitation trims are designed for clean, cavitation, and low flow applications with a maximum pressure drop of 51.7 bar (750 psi). Rather than eliminating cavitation, the trim is designed to control where it occurs to minimize losses.
specification
Certified in accordance with SIL ...
|
|
Fisher/Fisher Vee-Ball™ V300 Flanged Control Valve NACE compliant
Introduction: The Fisher/Fisher Vee-Ball™ V300 Flange Control Valve features a hemispherical valve with a specially designed corrugated V-notch. The Vee-Ball Control Valve combines the ruggedness of a linear valve with the high efficiency of a rotary valve.
|
|
Fisher/Fisher Models 119, 119EZ, and 119EZS Changeover Valves
The Model 119 switching valve is used for on/off or throttling control of non-corrosive or slightly corrosive gases. They are designed to meet the requirements of low-pressure gas applications in a variety of industries. The 119EZ and 119EZS are used as fuel gas valves for oil and gas natural draft burners. The product comes with a built-in speed control ...
|
|
Fisher/Fisher Model R622H Primary Regulator
The Model R622H regulator is certified by Underwriters Laboratories (UL), United States Safety Testing Laboratories, Inc., for use in LPG two-stage pressure regulating systems. The outlet pressure of the liquefied gas storage tank is reduced to 10 psig / 0.69 bar after being regulated by a pressure regulator.
peculiarity
Build...
|
|
Fisher/Fisher EZ-OVT trim
The Fisher EZ-OVT trim is a dual-seated trim designed for long-term, tight shut-off in on/off applications where fluids contain particulates, such as catalyst powders. These valves are suitable for controlling and cleaning hydrogen used in the refining process of UOP Continuous Catalyst Regeneration (CCR).
|
|
Fisher/Fisher Yarway AT-37/47 Cryogenic Injector
Fisher Yarway cryogenic injectors have been specifically developed to inject process fluids into process gases at low temperatures.
specification
Equal percentage of flow characteristics, equal percentages of linearity, correction, etc., specialization
Materials: 304 stainless steel, 316L stainless steel, 316 stainless steel
The operating temperature is ultra-low ...
|
|
Fisher/Fisher A31D double flange butterfly valve
The Fisher A31D is a double-flanged high performance butterfly valve with either a splined or flat key actuated shaft. The A31D is used in throttling or on/off applications and models include NPS 3 to 12, CL150, and CL300.
Certified PED, CRN, Fugitive Emissions, NACE, ATEX, CUTR, Fire Safety...
|
|
Fisher/Fisher 670 Series Panel Mount Load Regulators
The 670 Series Panel Mount Regulator is a compact and rugged unit designed primarily for manually loaded pressure-balanced gas regulators to provide manual control of the diaphragm actuator control valve.
peculiarity
Control flexibility
Easy fingertip control
Easy to connect
specification
Maximum inlet pressure without shear ...
|
|
Fisher/Fisher HP Series Control Valves
The Fisher HP Series Control Valve is a single-port, high-pressure, globe or angle valve with a metal seat, cage guide, and push-down to shut-off plug action. These valves are designed for high-pressure applications in the process control industry, such as power generation, hydrocarbon production, chemical processing, and oil refining.
...
|
|
Fisher/Fisher 4660 Pneumatic High and Low Pressure Conductor
The Fisher 4660 pneumatic pilot-operated pressure controller activates a safe shutdown system for flowlines, production vessels, and compressors. The pilot is available in single or dual setpoint capability models that use a switching point to maintain full output pressure when the process pressure is within the set point range. If the process ...
|
|