The Fisher/fisher ASCO Series 614 SentronicPlus is a digitally operated, three-way proportional regulator. Adjustable pressure, flow, force, speed, and linear or angular position. Air and inert gas media can be controlled. According to the ATEX Directive 2014/34/EU, its construction allows use in potentially explosive atmospheres. The valve's components are designed to be controlled with very low hysteresis accuracy. Using ASCO Data Acquisition Software (DaS) and PC connectivity, valve control loop parameters can be easily configured and optimized for specific customer requirements. The valve can be used in applications with high dynamic pressure requirements.
peculiarity
Whether the pressure is increased or discharged, the same fast response is achieved because the valve ports have the same bore
Intelligent digital communication for simple operation
Dual-loop control makes it easy to configure process variables such as flow, force, speed, RPM, and temperature
The integrated display makes it easy to monitor the valve status
The DaS software can be individually selected to optimize the performance of the control loop
Vacuum service models and high-pressure (725 psi) signals are available for you to choose from
|
More on that
|
Emerson's new gas detectors protect employees and property by warning of hazards in extreme environments
Emerson's new gas detectors protect employees and property by warning of hazards in extreme environments
Easy to install and commission, Rosemount open-circuit gas detectors can trigger toxic and flammable gas alarms over a wide area.
Shanghai, China (November 16, 2021) ...
|
|
Fisher Fisher - Analysis of the future trends of global valve products
With the development of large-scale complete sets of foreign technology, a series of new complete sets of equipment and stand-alone machines have emerged. The development of new sets of valve-related complete equipment is characterized by large-scale, high-parameter, high-performance automation and complete sets, which are compatible with the control mode of these complete sets of equipment. In the past 20 years, the country ...
|
|
Classification and precautions for use of Fisher valve positioners
Fisher Fisher Valve Positioner Type, according to the structure, is divided into Fisher 3660/3661/3710/Pneumatic Valve Positioner, FISHER3528I Electric-Pneumatic Valve Positioner and Fisher DVC6200/DVC2000 Digital Intelligent Valve Positioner, which has single acting and double acting, and is the main attachment of the control valve.
|
|
Fisher Fisher - Hazards and Protection of Abnormal Pressure Boost in the Cavity of Gate Valves
Gate valves usually have single ram, double ram, wedge, parallel and other structural designs, among which wedge double ram (Z42, Z62 series) and wedge elastic ram (Z40, Z60 series) are widely used, the former when the gate is closed, the gate automatically fits the valve seats on both sides, and automatically compensates the processing position of the wedge angle.
|
|
Fisher Fisher-Valve Seal Face Material Considerations
The sealing surface is the key working surface of the valve, the quality of the sealing surface directly affects the service life of the valve, and the material of the sealing surface is an important factor to ensure the quality of the sealing surface. Therefore, the following factors should be considered when selecting the valve sealing face material:
(1) Corrosion resistance.
"Corrosive" ...
|
|
Features and selection of valve actuators
Peculiarity:
Merit:
1. Ultra-miniaturization can be realized
2. Wide range of output torque
3. It is easy to control, and can freely use various signals such as DC, AC, short wave, pulse, etc., which is suitable for amplification, memory, logical judgment and calculation
shortcoming
1. Complex structure
2. Mechanical ...
|
|
Fisher Fisher - Adjustment method for valve positioner pneumatic control valves
Fisher valve positioners use an I/P electrical converter that converts an electrical signal into a gas signal. So what do we need to pay attention to during the conversion process? How do I make the switch? Here's how it goes.
The I/P electrical converter of the Fisher valve positioner is made from a gas source through a constant throttle ...
|
|
United States Fisher pneumatic valve positioner fault repair and protection methods
United States Fisher Pneumatic Valve Positioner is the primary accessory to the Pneumatic Control Valve, which is a single-output valve positioner. It describes the main features and common faults of the valve positioner, as well as the treatment methods and protection methods.
1. The main features of the locator
(1) Large-diameter pilot ...
|
|
Fisher Fisher – Commonly used valve packing types and functions
1. Compressed filler
(1) Plant fiber filler
Made of hemp or cotton impregnated with oil, wax or other impermeable materials for use on low-pressure valves below 100°C. It is suitable for water, ammonia and other media.
(2) Asbestos fiber filler
Asbestos fibers have good heat resistance, can resist weak acids, strong alkalis, ...
|
|
Fisher Fisher - Teaches you how to improve the life of your valves
In the valve design or use experience, the lifting valve packing is mostly asbestos packing or graphite packing or PTFE V-type packing, but these packings are limited by the number of valve opening and closing, that is, with the increase of the number of valve opening and closing, the packing will wear out, and the gap will gradually increase, to a certain number of times.
|
|
Fisher Fisher - Introduction to commonly used valve sealing face materials
1. Soft sealing material
(1) Butadiene rubber (NBR). Butadiene rubber has excellent oil resistance; The heat resistance is better than that of natural rubber and styrene-butadiene rubber; Good air tightness and water resistance. Dingjing rubber can be divided into Dingjing-18, Dingjing-26 and Dingjing-40. Xiangjing rubber is suitable for temperatures from -60 to +120 degrees ...
|
|
Inlet and outlet piping design of the pump
Cavitation: When the static pressure of the liquid entering the first-class impeller in the pump is lower than or equal to the saturated vapor pressure at this temperature, the liquid vaporizes and produces bubbles. This vaporization and condensation produce ...
|
|
Fisher Fisher - Analysis of the level of valves in China's nuclear power
At present, 19 domestic enterprises have obtained the civil nuclear pressure equipment planning and production qualification license issued by the National Nuclear Safety Administration, which can plan and produce nuclear-grade valves. The types of planning and production valves include gate valves, globe valves, check valves, ball valves, butterfly valves, tension spring safety valves, and regulators.
|
|
Fisher Fisher - Dead Band Adjustment for Electric Actuators
1. Definition of dead zone
In the field of instrumentation, it is also known as the insensitive area of the instrument. A finite interval in which a change in the input does not cause any perceptible change in the output of the instrument. The dead zone is mainly caused by friction and intermittent intermittent between the internal components of the instrument.
In the field of valves, valves are dead ...
|
|
Fisher valve positioner commissioning steps
Fisher valve positioner commissioning steps
Step 1: Connect the Rosemount 475 communicator
1. Enter the interface and select HART; Enter after selecting online; If there is an alarm signal, select YES and enter;
2. Select configure from the online drop-down menu and press the ente ...
|
|
Fisher - How China's valve companies are accelerating the growth of the industry
According to the China Valve Association, the total annual sales of 773 enterprises in 2005 was 25.935 billion yuan, and it can be presumed that the national valve output value in 2005 was 36.144 billion yuan. And more than 20 scouts were interviewed, according to their predictions, the total annual sales of China's valves in 2010 was 6.736 billion yuan.
Valve industry ...
|
|
Fisher Fisher - Gas Pressure Reducing Valve Operating Principle and Selection Criteria
The gas pressure reducing valve is to control the opening of the opening and closing parts in the valve body to adjust the flow of the medium, reduce the pressure of the medium, and at the same time adjust the opening of the opening and closing parts with the help of the pressure behind the valve, so that the pressure behind the valve is kept within a certain range, and the cooling water is sprayed in the valve body or behind the valve to reduce the pressure of the medium.
|
|
Fisher Fisher - Why do steam pipes often have to be bent a section?
We often see such a scene on the steam pipeline, the pipe section that can be "straight" suddenly bent a section, I believe that many people who have seen it will have such doubts like me, this is not "painting snakes", in fact, the design of the pipeline operation has its own original...
|
|
DVC6200 &DVC2000 Smart Positioner Online Performance Diagnostics - Fisher Fisher Valves
Fisher's Fisher Valve DVC6200 &DVC2000 Smart Positioners allow users to configure, calibrate, and adjust their instruments, bringing a new level of reliability to the range of products through years of experience in the control industry. This helps to identify problems accurately without interrupting the process ...
|
|
Emerson introduces the Fisher L2e level controller
Emerson has introduced the Fisher L2e Level Controller, which provides comprehensive electric level control for a wide range of applications in production and process systems.
The new Emerson Fisher L2e controller uses a force-balanced displacement sensor to detect the level of a single liquid or two...
|
|