Switching power supply failure maintenance - Senlan

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

In the process of repairing the switching power supply, the step-down method can be selected. The method is: by connecting the power plug of the display to a communication voltage regulator, and then adjusting the output voltage of the voltage regulator to about 100V, and then repairing it with electricity, and gradually improving the power supply voltage for repair. Here are a few examples of repairs.

                              Switching power supply failure maintenance - Senlan

Example 1: The fuse blows out when the machine starts, and the output voltage is zero. This condition is generally caused by the breakdown of the switch tube and the short circuit of the emitter collector. At this moment, the switch can be removed first to measure the resistance of the emitter and collector to the ground. If it is zero or very small, it can be replaced. And also to see if there are any problems with other parts before starting the machine.

Example 2: The grating is distorted into an "S" shape. This kind of problem should be concentrated in the filter circuit and the voltage regulator circuit. Generally, a diode is open, and the rectification changes from full-wave to half-wave rectification. This may also be due to the reduced capacitance of its filter capacitors.

Example: Communication 220V rectifier filter circuit short circuit problem, as soon as it is turned on, it will burn out. First, check whether the rectifier diode is short-circuited and whether the filter capacitor is severely leakage. It is also possible to unplug the degaussing coil to see if the degaussing thermistor has a short circuit and replace it with a new one.

Example 4: No grating, no display, no power indicator, but no fuse. At this moment, check whether the communication transformer is open, whether the current limiting resistance of the rectifier circuit is open (burned out) or whether the rectifier diode is open.

Example 5: No grating, no display, the machine has abnormal noise. If a squeak is announced, indicating that the vibration frequency is low, the parts associated with the vibration should be looked at. If a squeak is announced, indicating that the power supply is overcurrent maintenance, look at the overcurrent maintenance circuit.

Example 6: The output voltage is higher or lower than normal. The output voltage is tens of volts to tens of volts higher or lower than the normal value, but not zero, and the maintenance circuit is not working. At this moment, the fault phenomenon will change with the change of voltage. If the output of the adjustable potentiometer is stable or changes slightly, it is clear that there is a fault with the sampling differential circuitry and the Zener diode supplied to the reference is likely to be broken down or short-circuited.

More on that
Senlan direct torque control principle Senlan direct torque control principle

The direct torque control (DTC) function of the inverter is another high-performance communication frequency conversion speed regulation system developed after vector control. In the mid-80s of the 20th century, the German scholar Depenbrock proposed the theory of direct torque control in 1985, and his idea was to combine the electric motor and the inverter.

Analysis of the causes of bearing damage - Hope Sunland Analysis of the causes of bearing damage - Hope Sunland

In the process of using bearings, often due to some external factors cause some wear in the rotation of the bearing, and these bearing wear will be completely damaged in the addition of day by day, which requires our maintenance personnel to replace the bearing, and generally form a bearing.

Motor encoder and rotor pole phase zero alignment repair - Sunland Motor encoder and rotor pole phase zero alignment repair - Sunland

1. Phase alignment method of incremental encoder The alignment between the phase of the UVW electronic transmutation signal and the phase of the rotor pole, or the phase of the TV spot, of the incremental encoder with the signal exchange is as follows: 1) Use a DC power supply to pass the UV winding of the motor to less than the amount of ...

What is the energy feedback of the inverter - Senlan inverter What is the energy feedback of the inverter - Senlan inverter

The essence of energy feedback is active inverter, and the realization method of energy feedback of general inverter is to feed renewable energy to the grid with an anti-parallel three-phase inverter at the uncontrolled rectification of the pre-stage of the general inverter. The main circuit of the energy feedback equipment is mainly composed of thyristors, IGBTs and IPM modules.

Sunland inverter braking resistor connection Sunland inverter braking resistor connection

Assuming that the inverter has a built-in braking unit and additional braking resistors, it is important to pay attention to the correct wiring of the braking resistors. The braking resistor should be connected between the P terminal and the DB terminal, but not between the P terminal and the N terminal, otherwise the three-phase rectifier bridge will operate at full load when it is not working, resulting in the equipment being unable to ...

Causes and solutions of inverter skipping current faults - Senlan Causes and solutions of inverter skipping current faults - Senlan

1. There is a short circuit to the ground in the output circuit of the inverter, you can check whether the wiring is correct and troubleshoot 2. If the motor parameters are incorrect, you can check the parameter settings and identify the parameters 3. The acceleration time is too short, and the acceleration time can be increased.

Inverter rectifier unit static detection mode Inverter rectifier unit static detection mode

The method of judging the damage of a power element in the rectifier part is to manipulate the single conductivity of the rectifier element, and the positive and negative resistance values should not be consistent when the static value is general, and the specific method is as follows: The three-phase bridge rectifier of the rectifier part may be two...

Excessive capacity of the inverter causes harm to electrical equipment - Senlan inverter Excessive capacity of the inverter causes harm to electrical equipment - Senlan inverter

(1) The harmonic current generated will directly cause the additional heating of the motor, so that the stator of the motor surpasses the additional temperature rise of the motor itself, so that the additional output capacity of the motor will be greatly reduced. (2) The current output of the inverter ...

Senlan inverter selection principle Senlan inverter selection principle

1. Select the inverter according to the load characteristics, such as the load is constant torque load, you can choose Siemens MM440 inverter, ABB ACS800 series inverter, etc.; If the load is a fan or pump load, you can choose Siemens MM430 inverter, ABB ACS510 series inverter, etc. 2、 ...

The sequence of inverter commissioning steps - Sunland inverter The sequence of inverter commissioning steps - Sunland inverter

Investigation of the function of the inverter system Before debugging the inverter, it is necessary to carefully read the instruction manual and related information of the inverter to be debugged to understand the use environment and precautions. Especially before the inverter is energized, it is necessary to carefully investigate and check whether the inverter has obvious problems.

The selection of the speed control mode of the universal inverter - Senland The selection of the speed control mode of the universal inverter - Senland

How to choose the speed control form of the general inverter: the general inverter is also known as the high-performance inverter, the PG-free vector inverter, and the torque control inverter, why? Originally, the main speed control form is different, so how to choose the speed control form of the inverter? ...

Application of Sunland inverter in sugar separator Application of Sunland inverter in sugar separator

First, the operation of the machine before the technical transformation The sugar separation process of a sugar factory in Yunnan uses centrifugal dehydration method. The separation machine is mainly composed of a cone drum and a drive motor, and the motor shaft is directly connected to the bowl. Solid sugar crystallized from a high concentration of sugar water, in a cone bowl ...

Whether the front end of the inverter can be installed with a motor protector - Senlan Whether the front end of the inverter can be installed with a motor protector - Senlan

Frequency conversion speed regulation motor is generally selected 4-level motor, the fundamental frequency operation point is planned at 50Hz, the frequency 0-50Hz (speed 0-1480r/min) scale of the motor for constant torque work, the frequency of 50-100Hz (speed 1480-2800r/min) scale of the motor for constant power work, the whole speed regulation scale of (0 ...

The overload capacity of the dry-type transformer - Sunland inverter The overload capacity of the dry-type transformer - Sunland inverter

Dry-type transformer is a kind of power equipment, and under normal circumstances, dry-type transformer also requires a certain amount of overload, that is, the workload beyond its working ability. So what about the overload of dry-type transformers and how to influence them? ...

Limit switch wiring method - hope Senlan Limit switch wiring method - hope Senlan

Limit switch is an electromechanical control element used to detect the direction of the movement of the machine or equipment, and send a signal when the specific position is in a specific direction to control the operation or stop of the equipment. It is often used in industrial production processes, such as CNC machine tools, conveyors, loading and unloading robots, etc. ...

The harm of low temperature to the inverter - Senlan The harm of low temperature to the inverter - Senlan

Most VFDs are suitable for -10°C-50°C, and if the temperature is too low, the VFD will be affected. Precautions for low-temperature operation of VFD: 1. VFD should be operated in an environment above minus 10°C as much as possible, preferably indoors.

Common problems in the use of inverters - Hope Sunland Common problems in the use of inverters - Hope Sunland

1. Please clarify the maintenance function of the inverter? (1) After detecting the abnormal situation, take the initiative to correct the action, such as overcurrent loss speed prevention, regeneration overvoltage stall prevention. (2) Block the power semiconductors after detecting the abnormality...

Differential overhaul method of inverter - Senlan Differential overhaul method of inverter - Senlan

For the dual requirements of anti-interference and galvanic isolation, the pre-circuit of the output current detection or voltage detection of the inverter usually uses the "matching" circuit of the linear optocoupler device and the differential amplifier to complete the transmission mission of the detection signal. The circuit of the differential amplifier is based on the current detection circuit ...

How to carry out frequency conversion of frequency converter - Senlan How to carry out frequency conversion of frequency converter - Senlan

(1) Rectifier. As one of the most important components of the inverter, the rectifier can convert the AC power into direct current. Its working method is more common to that of a battery charger or arc welder. It uses a diode bridge to limit the communication sine wave to only one direction.

Motor inverter principle and precautions for use - Senlan Motor inverter principle and precautions for use - Senlan

The difference between a voltage converter and a current converter Voltage inverter and current inverter are two different operating principles, for example, the operating principle of voltage inverter is mainly to regulate the voltage source, and the voltage source regulates the current to achieve the effect of conditioning, while the current inverter is a direct ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top