RKG thermostat – the scope of application of underfloor heating thermostats
1) Separate households are independently heated, and floor heating is installed in small households, and boiler temperature control is applicable.
2) Separate households independent heating duplex building installation floor heating room temperature control.
3) Separate households for independent heating, large duplex villas are suitable for floor heating stratified temperature control.
...
|
|
RKC Level Gauge – Key points for using a float level gauge
1. The level gauge is adjusted normally, and it is found that the float is "absorbed" for a period of time in a certain position after it is put into use. This is mainly caused by the level gauge passing through the steel platform device and being spaced too close to the steel plate. Therefore, it is necessary to pay special attention to the level gauge to connect the pipe wall with the steel platform device.
|
|
Difference Between Thermocouple and RTD
In temperature measurement, thermocouples and RTDs are both contact temperature measurements, and although they both measure the temperature of an object, their principles and characteristics are different.
This article first introduces thermocouples, which are widely used in temperature measurement temperature control devices.
|
|
RKC Thermostat How to properly select and use a pressure sensor
High-temperature melt pressure sensors, transmitters, and high-temperature melt pressure gauges are special equipment in extrusion processing.
On the production line, melt pressure sensors play an important role in improving melt quality, increasing production safety and protecting production equipment.
Use...
|
|
RLC thermostat – the wiring method of the thermostat
Many household appliances and large-scale equipment products will be installed in the use of thermostats, thermostats will be combined with the change of ambient temperature in the switch when working physical deformation, which will produce some special effects, resulting in conduction or disconnection action, in order to achieve automatic ...
|
|
The main role and service life of the thermostat - RLC
In most cases, in Europe, the thermostat is a necessary accessory for the wall-hung boiler, and the two are delivered to the user at the same time, and most of the thermostats equipped are intelligent thermostats. In China, nearly 95% of the wall-hung boilers that have been installed in operation and are being installed and debugged and ready to be put into use are not equipped in advance.
|
|
RKC thermostat - what should be paid attention to when maintaining the thermostat?
1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use.
2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...
|
|
Where you need to pay attention to the wiring of the RRKC thermostat
1. For thermocouple input, the corresponding compensation wire should be used.
2. RTD input, 3 wires with low resistance and no difference should be used.
3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference.
4. Instrument power cord ...
|
|
RRC thermostat - how to adjust the smart thermostat
1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET button digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, long press the △ key or ▽ key The data will change rapidly, press the SET key again ...
|
|
RKC level gauge - the fault and treatment method of float level gauge
Fault 1, the indication is abnormal
The float level gauge is not indicated properly and is a very common fault of the float level gauge. Usually there are the following manifestations:
Phenomenon 1: The float level gauge in the atmospheric pressure workshop has the largest indication.
Troubleshooting: The float was found to be ...
|
|
RKC Level Gauge – The structure of a float level gauge
(1) For the indicator, also known as the display panel, the indicator plays the role of local display, convenient for long-distance observation of the actual situation of the liquid level, the indicator is generally bundled with the pontoon, easy to install.
(2) It is a magnetic float, which is located in the pontoon and is in direct contact with the liquid to be measured, ...
|
|
RRC thermostat - the principle of sudden jump thermostat, how to judge the good or bad?
1. What is the principle of the sudden jump thermostat?
The sudden jump thermostat is a kind of thermostat, which is a series of automatic control elements that are physically deformed inside the switch according to the temperature change of the working environment, resulting in some special effects and on-off action. Sudden jump ...
|
|
RHK thermostat – a rapid detection method for common air conditioner thermostats
1. Bellows or diaphragm air conditioner thermostat
Fault Symptom:
Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The leakage of the thermostat in the temperature sensing chamber causes the contact to fail to operate and lose control ...
|
|
RK Thermostat - The working principle and device precautions of liquid expansion thermostat
How liquid expansion thermostats work
Liquid expansion thermostat is a physical phenomenon (volume change) that causes the material (generally liquid) in the temperature sensing part of the thermostat to undergo corresponding thermal expansion and cold contraction when the temperature of the controlled object changes, and the diaphragm box connected with the temperature sensing part expands or ...
|
|
RKC Level Gauge - the principle of the selection of float level gauges
The float level gauge is widely used, mainly used in petroleum processing, food processing, chemical industry, water treatment, manufacturing, electric power, papermaking, metallurgy, ships and boilers and other industrial automation processes to measure and control the level.
1. Pay attention to the specific working conditions. As introduced ...
|
|
Steps for the correct adjustment of the thermostat
1. First of all, determine the set temperature of the thermostat and make sure that it is the same as the temperature you need.
2. Recognize the operating form of the thermostat, usually there are two forms of cooling and heating, and choose the corresponding form according to the demand.
3. Acknowledging the operating condition of the thermostat, usually with active ...
|
|
RKC Thermostat - How to Choose a Hot Spot Couple?
The selection of thermocouples should be based on comprehensive considerations such as the scale of the operating temperature, the required accuracy, the atmosphere of the application, the performance of the measurement target, the response time and the economic benefits.
1. Selection of measurement accuracy and temperature measurement scale
1) The operating temperature is 1300-1800 °C, and the accuracy is required to be more accurate than ...
|
|
Key features of the RLC thermostat:
Thermocouples, RTDs, analog and other signals are freely inputted, and the range can be set freely;
The software zeros the full degree, the cold end measures the temperature separately, the amplifier is self-stabilizing, and the display accuracy is better than 0.5%FS;
Fuzzy theory combined with traditional PD method, fast and stable control, advanced tuning ...
|
|
RK Level Gauge - Typical Fault Problems and Solutions of Pontoon Level Gauges
1. There is no liquid level display or lower liquid level display
When the sewage is discharged, only a small amount of condensate flows out, and it is judged that the pontoon is blocked.
Treatment: Dismantle the outer pontoon and find that the pontoon is almost filled with dirt and impurities. Clean, calibrate, and return to normal.
2. The liquid level display is ...
|
|
RRC Thermostat – Instructions for use of smart thermostats
1. Turn on the power of the smart thermostat, and the current temperature is displayed on the display. Because the sensor is not in contact with other devices, but is exposed directly to the air, this is the current temperature: 31 degrees Celsius, which is not too hot.
2. At the bottom right of the display is the "Startup Temperature" setting.
|