Sick Information SHOW
Sick's 3D vision product Ruler series has been newly upgraded! Sick's 3D vision product Ruler series has been newly upgraded!

Recently, Sick's 3D vision product Ruler series has been newly upgraded! The new products Ruler3002, Ruler3004 and Ruler3010 are officially available today!   01. Product characteristics • Contour point upgrade: up to 3200 Data points/Profile • Ultra-high scanning speed ...

Sick released a new product, the safety camera safeVisionary2 Sick released a new product, the safety camera safeVisionary2

With the practical application and demand of security protection, the existing 2D protection equipment has gradually been unable to meet the customer's requirements for safety, and the demand for 3D safety equipment is getting higher and higher. Today we are launching a new product from SICK---safeVisionary2.

Overview and benefits of the IDM mobile handheld barcode scanner Overview and benefits of the IDM mobile handheld barcode scanner

Overview Identification codes are easy and secure IDM's mobile handheld barcode scanner reliably recognizes 1D and 2D codes, including stacked codes such as PDF417. Depending on the field of application and environmental conditions, a standardized or rugged IP65 degree of protection can be provided.

Presentation of the Sick Multi Physics Box sensor Presentation of the Sick Multi Physics Box sensor

advantage Processes are more transparent and machine downtime is less The Multi Physics Box enables Condition Monitoring. Whether it's motors, pumps, conveyor belts or fans – the measured values of temperature, vibration behavior and shock show the phase...

SICK new product launch - ZS36x8 SR version handheld barcode scanner SICK new product launch - ZS36x8 SR version handheld barcode scanner

Since its launch, the SICK ZS36x8 DPM has been well recognized by customers, hitting the pain points of customers for DPM code recognition, and has excellent results in demanding applications in electronics, lithium batteries, automobiles and other industries.   In order to better meet the needs of the domestic conventional market and meet the needs of logistics and factory automation.

Applications of Sick photoelectric sensors Applications of Sick photoelectric sensors

Photoelectric sensors that use optoelectronic components as sensitive components have a wide variety of types and applications. According to the nature of the output of photoelectric sensors, they can be divided into two categories: (1) The photoelectric measuring instrument made by converting the measured into a continuously changing photocurrent, can be used to measure the intensity of light and the object ...

An introduction to the three common types of photoelectric sensors An introduction to the three common types of photoelectric sensors

1. Photoelectric switch sensor The occlusion between the transmitter and receiver is used to detect states such as motion, object presence, or object position. When the measured object passes through the occlusion beam, the intensity of the light signal received by the receiving head changes, which in turn triggers the switching signal. Photoelectric switch ...

Adjustment method of Sick sensor NT6-03022 Adjustment method of Sick sensor NT6-03022

1. Self-regulation. At the beginning of use, please check whether the switch itself is defective and whether the appearance is defective. 2. When avoiding obstructions. When the photoelectric switch is used, for some goods such as colored goods, goods with weak reflectivity, and goods with large gaps between small pieces...

Sick's new product launch - CODE LOC, for QR code positioning Sick's new product launch - CODE LOC, for QR code positioning

Today, with the development of intelligent logistics, have you ever encountered such a problem about unmanned AGV/AMR cars? SLAM navigation hardware is costly; high R&D expenses; LiDAR positioning and navigation may not be used in actual customer scenarios; In order to ensure efficiency, the speed of the trolley has a ...

Sick TMx22 tilt sensor – smaller, smarter Sick TMx22 tilt sensor – smaller, smarter

The miniaturization, integration, and intelligence of sensors are the main trends of industrial development, and the increasing demand for small and integrated smart chips in industrial scenarios also provides better means for equipment integration and intelligence. Sick is also deeply aware of the small size of the large ...

Adjustment method of the Sick WFS3-40N415 sensor Adjustment method of the Sick WFS3-40N415 sensor

(1) Automatic calibration: When the workpiece enters the sensitive area of the probe, press and hold the "SET" button for 3 seconds, and the sensitivity value will be set and displayed in green. (2) Two-point calibration: When the workpiece does not enter the sensitive area, hold and hold the "SET" button for three seconds, there is a ...

Steps on how to maintain the Sick sensor Steps on how to maintain the Sick sensor

1. It is necessary to prevent the sensor from contacting corrosive gases, so as not to cause corrosion and affect the measurement results. 2. If the measurement is a high-temperature medium, the Sick $ICK sensor should see whether the temperature is within the appropriate temperature range of the sensor.

Debugging method of Sick fiber optic sensor 180T Debugging method of Sick fiber optic sensor 180T

1. First, connect the external hardware and install the external COM port of the scanner to the serial port of the industrial computer. 2. The power supply of the SICK scanner control box is 24V positive and negative induction eyes, and the feedback signals of 10, 11 and 12 corresponding to the electric eyes, 24V+, 24V-. ...

How to set the parameters of the SICK UM30 fiber optic sensor? How to set the parameters of the SICK UM30 fiber optic sensor?

1. Connect the device: connect the power supply and electrical signal to the sensor, connect the output interface to the PLC, connect RS232 to the computer, generally use RS232, but also change to other control methods, such as CAN, RS485 and so on. 2. Software installation: Open the laptop, install ...

Sick Sensors - Analysis of common fault codes for fiber optic sensors Sick Sensors - Analysis of common fault codes for fiber optic sensors

1. Alarm code E401 E401 is one of the common fault codes of fiber optic sensors, which indicates that the fiber optic sensor has detected that the fiber is cracked or bent. This problem can usually be dealt with by replacing the fiber or adjusting the fiber installation orientation. 2. Alarm code E402 ...

Adjustment method of sensing distance of Sick photoelectric sensor Adjustment method of sensing distance of Sick photoelectric sensor

1. Find the screw at the end of the switch, twist it clockwise to adjust it far, and twist it counterclockwise to adjust it closer. 2. It can increase the intensity of the light source. 3. Improve the sensitivity of the switch sensor. 4. It can also be adjusted according to the instructions for use. ...

Adjustment method of the Sick WFS3-40N415 sensor Adjustment method of the Sick WFS3-40N415 sensor

(1) Automatic calibration: When the workpiece enters the sensitive area of the probe, hold down the "SET" button for 3 seconds, and the sensitivity value will be set and displayed in green. (2) Two-point calibration: When the workpiece does not enter the sensitive area, press and hold the "SET" button for three seconds.

Introduction to the functional characteristics of SICK's safety switches Introduction to the functional characteristics of SICK's safety switches

1. When the load exceeds the action current, the circuit will be automatically cut off. 2. After the circuit is automatically cut off, the panel indicator light is on, which is convenient for judging the fault part. 3. After troubleshooting, press the red button at the bottom of the panel to restore the normal power supply. 4. For other reasons, the shell ...

How to adjust the SICK UM18-51112 sensor How to adjust the SICK UM18-51112 sensor

Preparation tools: calibrator to change the distance of the ultrasonic sensor, special regulator and special power supply. Disconnect the power supply: Disconnect the ultrasonic sensor from the controller and prepare it for commissioning. Commissioning time: The commissioning time can be adjusted to any time to meet the needs of personalization.

Next Page »
12345678
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top