Debugging method of Sick fiber optic sensor 180T

Create Date: 2024-8-30 12:03:23|Source: SICK/Sick

1. First, connect the external hardware and install the external COM port of the scanner to the serial port of the industrial computer.

2. The power supply of the SICK scanner control box is 24V positive and negative induction eyes, and the feedback signals of 10, 11 and 12 corresponding to the electric eyes, 24V+, 24V-.

3. The output connection of the SICK control box outputs the alarm signal to drive the alarm lamp, and 20, 21, and 22 correspond to the output signal 1, 2, and the common end. The output signal is 24V+, and the signal output conditions can be set from the software.

4. After the hardware installation is completed, it needs to be installed, after the installation of the scanning software is completed, the 24V power supply will be provided, and the scanner will be connected to the connection port of the computer.

5. Open the software and connect the scanner. Click "Upload all device parameters" to upload the device settings.

6. After setting the above parameters, you need to download the file content to the scanner, click the "Download" button to download the parameters, and select "Save Permanently".
Debugging method of Sick fiber optic sensor 180T

More on that
Sick sensors – the seven basic types of temperature sensors Sick sensors – the seven basic types of temperature sensors

1. Thermocouples Thermocouples are voltage devices that indicate temperature measurement when voltage changes. As the temperature increases, the output voltage of the thermocouple increases – not necessarily linear. Thermocouples are typically located inside a metal or ceramic shield to protect them from exposure to a variety of environments. ...

The application of Sick 3D vision in the steel industry The application of Sick 3D vision in the steel industry

With the rapid development of industrial automation in recent years, machine vision, as a smart brain endowed with "eyes" to machines, has been widely used in various fields of intelligent manufacturing. In the context of the rapid penetration of artificial intelligence in the Internet and emerging industries, traditional industries are also constantly promoting intelligent ...

Causes and solutions for the easy misdetection of SICK color scale sensors Causes and solutions for the easy misdetection of SICK color scale sensors

Reasons for false detection: 1. The installation distance is inappropriate Different from the identification of the reflective intensity of ordinary photoelectric switches, because the color mark sensor recognizes the grayscale contrast, if the measured material is not placed within the detection distance, its sensitivity (grayscale recognition ability) is significantly reduced, and even cannot be ...

SICK Safe EFI-pro: The new generation of SICK safe communication protocol SICK Safe EFI-pro: The new generation of SICK safe communication protocol

In this issue, we will delve into the technical details of the Safe EFI-pro System, and then we will share with you about the typical application scenarios of the Safe EFI-pro System. 1. What is Safe EFI-pro System? Safe EFI-pro: The new generation of SICK ...

Sick Sensors - Applications and Attention Problems of Infrared Sensors Sick Sensors - Applications and Attention Problems of Infrared Sensors

Infrared sensors are sensors that use the physical properties of infrared rays to make measurements. Infrared, also known as infrared light, has the properties of reflection, refraction, scattering, interference, absorption, etc. Any substance that has a certain temperature above absolute zero can radiate infrared rays. ...

Sick launched a new diffuse reflection long array photoelectric sensing Sick launched a new diffuse reflection long array photoelectric sensing

The logistics industry has always been a strong area of SICK, in response to the detection of various goods on different conveyor lines and the diverse needs of customers, SICK has launched a series of photoelectric sensors such as G6, Z18, W16, W26 and Ray26 - which can detect cartons, baskets, uneven appearance, transparent bottles, laminated bags, etc.

Sick Sensors – the working principle and failure analysis of displacement sensors Sick Sensors – the working principle and failure analysis of displacement sensors

Linear displacement sensors work on the same principle as a sliding rheostat and are used as voltage dividers, which represent the actual position of the measured position with a relative output voltage. There are the following requirements for the work of this device: First, if the electronic ruler has been used ...

SICK 3D vision is used in high-speed smart home spraying applications SICK 3D vision is used in high-speed smart home spraying applications

With the development of Industry 4.0, the intelligent level of the production line of high-speed smart home enterprises has been continuously improved, and the processes of cutting, edge banding, drilling, sorting, spraying, and packaging have been integrated to achieve a real "unmanned factory".   Intelligent and flexible production equipment allows robots to ...

SICK introduces the magnetic rotation sensor MAS SICK introduces the magnetic rotation sensor MAS

In the digitalization stage, the first step of the development path of Industry 4.0, Sick is committed to the design and development of intelligent sensors, aiming to lay a solid hardware foundation for digital transformation. Now, Sick has added a new member to the family of smart sensors – the magnetic corner sensor MAS. ...

Introduction to the advantages and disadvantages of Sick Sensors - thermistor temperature sensors Introduction to the advantages and disadvantages of Sick Sensors - thermistor temperature sensors

Advantages of thermistor temperature sensors: 1. Thermistors are highly sensitive and can easily detect temperature changes. 2. Most models can respond quickly to temperature changes, which can be completed in a few seconds. 3. The technology is mature, the cost is low, and the user ...

Adjustment method of Sick sensor NT6-03022 Adjustment method of Sick sensor NT6-03022

1. Self-regulation. At the beginning of use, please check whether the switch itself is defective and whether the appearance is defective. 2. When avoiding obstructions. When the photoelectric switch is used, for some goods such as colored goods, goods with weak reflectivity, and goods with large gaps between small pieces...

Where are the main applications of Sick Sensors – Laser Distance Sensors? Where are the main applications of Sick Sensors – Laser Distance Sensors?

Position monitoring of moving objects; Railway catenary survey, building limit survey; Measurement of objects that are not suitable for access; industrial automation and intelligent production management; Automobile speed and traffic statistics; Industrial monitoring signal trigger control; Tower crane ...

Detailed explanation of fault judgment and maintenance of SICK sensors Detailed explanation of fault judgment and maintenance of SICK sensors

Analysis of the factors that may cause the zero point change of the SICK sensor: overload will lead to a sudden change in the zero point, and the output resistance will obviously exceed the specified value impact, as above; Moisture return or turbidity, so it is mainly manifested as a continuous change of 0 point, high and low, etc., at this time, the ground resistance will be further reduced - in ...

LiDAR LOC | An embedded positioning software for AGVs/AMRs LiDAR LOC | An embedded positioning software for AGVs/AMRs

Product Introduction LiDAR LOC is an embedded positioning software for AGVs/AMRs. Maps can be used to create usable maps based on the environmental information collected by LiDAR, and mobile positioning data for AGVs and AMRs is provided in the form of UDP data output (x, y, and deflection angles). CAD compliance is also available.

What are the main uses of Sick sensors – laser distance sensors? What are the main uses of Sick sensors – laser distance sensors?

1. Laser length measurement Precision length measurement is one of the key technologies in the precision machinery manufacturing industry and the optical processing industry. Modern length measurement is mostly carried out by using the interference phenomenon of light waves, and its accuracy mainly depends on the monochromacy of light. Laser is the most ideal light source, it is more ...

Sick sensor - infrared sensor should be applied and precautions Sick sensor - infrared sensor should be applied and precautions

Infrared sensors are sensors that use the physical properties of infrared rays to make measurements. Infrared, also known as infrared light, has the properties of reflection, refraction, scattering, interference, absorption, etc. Any substance that has a certain temperature above absolute zero can radiate infrared rays. ...

Introduction to the performance of the W4F series of miniature intelligent photoelectric sensors from sick Introduction to the performance of the W4F series of miniature intelligent photoelectric sensors from sick

Friends who pay attention to Sick will not be unfamiliar with the W4-3 series products, this classic mini photoelectric is widely praised by the industry for its excellent set pressing function and diverse optical functions. Whether the object is a lubricated and reflective mobile phone surface, a wrinkled and dark food packaging bag, or ...

Steps on how to maintain the Sick sensor Steps on how to maintain the Sick sensor

1. It is necessary to prevent the sensor from contacting corrosive gases, so as not to cause corrosion and affect the measurement results. 2. If the measurement is a high-temperature medium, the Sick $ICK sensor should see whether the temperature is within the appropriate temperature range of the sensor.

Sick Sensors – How RTD sensors work Sick Sensors – How RTD sensors work

Thermal resistance is used to measure the temperature of a substance when its temperature changes, and its resistance also changes with the characteristics of the change. When the resistance value changes, the working instrument will display the temperature value corresponding to the resistance value. RTD sensors use the resistivity of conductors or semiconductors to change with temperature.

What are the characteristics of Sick Sensors – Contrast Sensors? What are the characteristics of Sick Sensors – Contrast Sensors?

1. Accuracy 2. Environmental conditions 3. Wavelength range 4. Calibration 5. Resolution 6. Cost 7. Repeatability 8. Frequency

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top