1) The installation of the switch panel should be after the installation of the lamp, and the switch must be connected in series on the live line; Application of sealed or protected sockets in wet locations; The allowable deviation of the verticality of the panel is not more than 1mm; The gap between the panels installed in rows should not be greater than 1mm. 2) Where the socket must be facing the switch panel ...
1. The fastener itself needs to be reliable and stable enough. 2. Need to rely on special tools to remove, such as hexagon screws, star screws, etc. Phillips/slotted screws are not recommended, as in some cases they can be easily fitted with fingernails or on the go.
1. The security door can also be called the anti-theft door, and the safety door switch, as the name suggests, is an automatic inductive control switch to ensure the safety of the door, and the opening and closing of the door needs to be detected by it to open and close. For example, this kind of safety door switch will be used in the community or factory, traffic, etc., which is conducive to monitoring ...
The safety switch prevents personnel from entering the hazardous area until all safety conditions have been met Provide bolt switches, safety magnetic switches, safety door lock switches, safety rope pull switches, emergency stop buttons, twisted chain interlocking switches, safety enable switches, safety limit switches, explosion-proof open...
Features of the safety door switch: The safety gate switch is composed of two independent parts: the switch body and the operating part of the switch. When the safety door is opened, the switch actuator is pulled out of the switch body and the normally closed contacts in the switch are disconnected by a mechanical rebound device. While...
ACMI S.p.A. is an Italy company specializing in high-tech bottling and packaging lines. Based in Fornovo Taro, in the province of Parma, Italy, the company initially produced palletizers and depalletizers for the food and beverage industry, and later specialized in all packaging processes. For...
In the safe configurable small controller series PNOZmulti 2 from Pilz, a new stand-alone base module PNOZ m C0 is now available. PNOZ m C0 has the structural characteristics of a safety relay, but it is just as powerful as a safety controller. It offers 8 ...
1. Choose the correct encoder model 2. Build the right safety loop 3. There is no blind spot in the installation of safety light curtains 4. The safety distance of the safety light curtain meets the requirements of EN ISO 13855 ...
Pilz's modular safety relay myPNOZ has received a lot of attention and acceptance since its introduction. It has been nominated for the Hermes Award, the Germany Innovation Award (GIA) and the Red Dot Design Award. This safety app, which can be customized and mass-produced according to user requirements, can be customized according to user requirements.
With the advancement of history, people have experienced the transformation from light industry to heavy industry, and then entered the era of automation brought about by innovation in the field of electronic computer technology and other scientific and technological fields. The wisdom and potential of human beings are limitless, and today in the 21st century, we are experiencing new ...
Single-phase servo amplifier (referred to as amplifier), with a variety of quarter-turn, linear stroke, multi-turn single-phase electric actuator (electric actuator) matching, widely used in industrial automation control process in the automatic adjustment system, this amplifier is an improvement of the traditional amplifier, compared with the traditional ...
Positional proportional gain 1. Set the proportional gain of the position ring adjuster; 2. The larger the setting value, the higher the gain, the greater the stiffness, and the smaller the position lag under the same frequency command pulse. However, too large a value may cause oscillation or overshoot; 3. Parameter value ...
Requirements for servo feed systems 1. Wide range of speed regulation 2. High positioning accuracy 3. There is sufficient transmission rigidity and high speed stability 4. Fast response, no overshoot In order to ensure productivity and processing quality, in addition to the requirement of high positioning accuracy ...
The new maintenance system "key in pocket" from Pilz prevents the risk of unauthorised machine restarts and increases the safety of maintenance work. Digital maintenance assurance is based on the access authorization system PITreader, which ensures the safety of machinery and industrial information.
1. After opening, establish a reliable insulation gap to separate the equipment or line that needs to be overhauled from the power supply with an obvious disconnection point to ensure the safety of maintenance personnel and equipment. 2. According to the operation needs, change the line. 3. It can be used to divide and combine small currents in the line, ...
When part of the production line no longer meets the current production needs, do you choose to buy new equipment or modify old equipment? Scheucher, a hardwood flooring manufacturer based in Austria, was faced with such a choice not so long ago. In Scheuch ...
1. The installation of the safety grating must be able to effectively prevent bypassing the detection area of the safety grating and contacting the dangerous moving parts, that is to say, the detection area of the installation grating can not have a blind spot, if the top or bottom of the safety grating has a fixed guard, the guard should be able to ...
Luminaire: emits infrared light and is composed of a plurality of light-emitting devices; Light receiver: Receiving infrared light, composed of a number of light receiving devices, one by one corresponding to the light emitting device of the luminaire, forming a protective light curtain, generating shading, light signal, and at the same time transmitting the signal through the signal cable to control...
1. Rated working voltage It refers to the voltage required by the coil when the relay is working normally. Depending on the model of the relay, it can be either AC voltage or DC voltage. 2. DC resistance Refers to the DC resistance of the coil in the relay, which can be passed by a universal meter.
Whether on the assembly line or on the machine, the safety rope pull switch is a proven and reliable solution for triggering an emergency stop function from any point on the pull rope to shut down dangerous work processes. Pilz's rope pull switch PSENrope is available in rope lengths up to ...
In the process of adjustment, cleaning, maintenance and repair of mechanical equipment, the unexpected start of equipment due to various reasons is one of the most typical accident causes. Many companies may also be struggling with how to effectively control unplanned start-ups during maintenance. In order to have ...
Brand Home
Pilz products
Pilz Information
Online Consultation:
Contact: Manager Huang
Contact QQ: 3271883383
Contact number: 13522565663
Weekdays: 9:00-17:00
Holidays: Only emergencies are handled