Methods to reduce the maintenance cost of inverter - Senlan inverter

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

Frequency converter is a widely used equipment in modern factories. This is a very expensive new type of equipment, and the maintenance price of the inverter is also very expensive, so in the process of using the inverter, we should pay attention to the use of the inverter.

                            Methods to reduce the maintenance cost of inverter - Senlan inverter

The physical environment is an important aspect of the use of the inverter, according to the maintenance of the inverter professional and technical personnel and his maintenance experience, most of the problems of the inverter are formed by the logistics environment of the inverter, mainly including the following three aspects:

1. Working temperature: There are many electronic components in the inverter, some of which will change the function with the change of temperature, and some will even be damaged by the temperature, therefore, it is recommended to control the normal working temperature of the inverter between 0-55 °C, and some simple heating items should not be connected to the inverter.

2. Ambient temperature difference: If the ambient temperature changes too much, condensation will occur in the inverter due to the temperature difference. When the inverter is started, it is simply burned out due to short circuit inverter and other reasons, therefore, in the place where the temperature difference between day and night is large, put some desiccant in the inverter, which will greatly remove condensation.

3. Corrosive gases. The internal electronic components of the inverter are not corrosion-resistant, and should not touch corrosive liquids and solids, however, corrosive gases can also cause damage to the components, so avoid excessive contact between corrosive gases and inverters.

More on that
Sunland low-voltage inverter division series Sunland low-voltage inverter division series

1.HG1000 high-performance light-load intelligent inverter, the most cost-effective, the new series is widely used in medicine, food, packaging, cable, printing and dyeing, washing, centrifuge, dehydrator, sewage treatment, HVAC, constant pressure water supply, constant temperature control, flow control and other industries, such as fans and pumps, ...

Sunland inverter control panel button function Sunland inverter control panel button function

1. The "FUNC/DATA" key is a programming key, press this button once to convert the operation mode, and press it again to read and write the function code; 2. The "SET/>>" button is the display switch and shift key, press this key to switch the display content, and press it again to ...

Inverter rectifier unit static detection mode Inverter rectifier unit static detection mode

The method of judging the damage of a power element in the rectifier part is to manipulate the single conductivity of the rectifier element, and the positive and negative resistance values should not be consistent when the static value is general, and the specific method is as follows: The three-phase bridge rectifier of the rectifier part may be two...

Causes and treatment methods of inverter inverter module damage - Senlan Causes and treatment methods of inverter inverter module damage - Senlan

Most of the damage of the inverter module is due to the damage of the driving electric, which causes the two switching devices on one bridge arm to be turned on at the same time. Inverter inverter power module damage is a common problem in other inverter equipment such as vector inverter or energy-saving inverter.

What is the energy feedback of the inverter - Senlan inverter What is the energy feedback of the inverter - Senlan inverter

The essence of energy feedback is active inverter, and the realization method of energy feedback of general inverter is to feed renewable energy to the grid with an anti-parallel three-phase inverter at the uncontrolled rectification of the pre-stage of the general inverter. The main circuit of the energy feedback equipment is mainly composed of thyristors, IGBTs and IPM modules.

Inverter with no-load operation debugging steps - Sunland inverter Inverter with no-load operation debugging steps - Sunland inverter

The following four steps are very important for the commissioning of the inverter with the machine (i.e., connected to the motor) and no-load (i.e., the motor without load). (1) Set the power of the motor, the number of pole pairs, and determine the working current of the inverter. ( ...

How to expand the application range of inverter - Sunland inverter How to expand the application range of inverter - Sunland inverter

In the electrical profession, the use and development of energy-saving frequency conversion is very good, which has promoted the electrical profession to reach the pinnacle of science and technology again. Frequency converter (VFD) has a very good development shape in China, but it still has to withstand various tests. As long as you give full play to your professional advantages, you can gain a firm foothold in this society. VFD ...

The control performance standard of the inverter cabinet The control performance standard of the inverter cabinet

The control specifications of the inverter cabinet include reliability, accuracy, safety, environmental habits and versatility, etc., which are important guarantees to ensure the normal operation and safe production of the inverter cabinet control system. Reliability specification: The control system should have high reliability and can be used for a long time.

Failure of robot contactor and inverter - Senland Failure of robot contactor and inverter - Senland

Robot contactors are noisy? Cause: It is likely that the joint contact surface of the contactor is uneven, and the surface is sand or rust. The result will constitute a phase loss, which will lead to the burnout of contactors, switch frequency conversion and other components. Solution: will control the ...

Application of Sunland inverter on gantry milling machine Application of Sunland inverter on gantry milling machine

The gantry milling machine is a machining equipment for processing larger workpieces, and its electrical control system includes two parts: the main transmission of the workbench and the logical control of the feed organization. Henan Jiaozuo Maike Company has a gantry milling machine, which has been used for many years since the 70s. The main drive of the operating table of the gantry milling machine is selected ...

How to carry out electrical system commissioning quota? ——Sunland inverter How to carry out electrical system commissioning quota? ——Sunland inverter

The commissioning of the electrical system refers to the commissioning of the entire high and low voltage system. The power supply commissioning of civil electrical projects such as general residences, schools, office buildings, hotels, and shops shall be carried out in accordance with the following provisions: (1) About the commissioning of the belt in the distribution room ...

Causes and solutions of inverter skipping current faults - Senlan Causes and solutions of inverter skipping current faults - Senlan

1. There is a short circuit to the ground in the output circuit of the inverter, you can check whether the wiring is correct and troubleshoot 2. If the motor parameters are incorrect, you can check the parameter settings and identify the parameters 3. The acceleration time is too short, and the acceleration time can be increased.

What are the peripheral equipment for inverter selection - Senlan inverter What are the peripheral equipment for inverter selection - Senlan inverter

After the inverter selection is completed, it is necessary to consider whether other peripheral equipment needs to be equipped according to the actual situation of the site. The peripheral equipment for frequency converter selection mainly includes circuit breakers, reactors, contactors, braking resistors, etc. 1. Circuit breaker ...

There is a problem with the inverter-controlled motor pressing the stop button There is a problem with the inverter-controlled motor pressing the stop button

What happens when the inverter-controlled motor presses the abort button, and the motor is not controlled to speed up? 1. If it is a newly installed inverter, it is generally necessary to consider the wiring problem, you can first change the parameters to switch to the panel control, the panel is given the frequency, and then see if the inverter operation will appear in this ...

Sunland inverter breakdown factor Sunland inverter breakdown factor

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the fact that the inverter voltage composed of various reasons exceeds the rated voltage, which is reflected in the DC voltage of the inverter DC bus. The overvoltage alarm generally appears at the time of shutdown, and its main ...

Inverter control scheme for fan and water pump - Senlan inverter Inverter control scheme for fan and water pump - Senlan inverter

There are many control methods for inverters for fans and pumps, which can be selected according to specific conditions. Here are a few common scenarios. (1) Manual adjustment This is the simplest control method, that is, the operator instructs according to the instrument, ...

Inverter line control mode - Senlan inverter Inverter line control mode - Senlan inverter

Each inverter (Variable-frequency Drive, VFD) is subject to different line control, and the methods of voltage control and current control can be divided into two categories, one is voltage type and the other is current type. The control mode can also be divided into voltage control and current type. The main circuit method and ...

Hope Senland's introduction to the charging module Hope Senland's introduction to the charging module

The charging module is a DC charging module developed to meet the high voltage and high current of electric vehicles. The module has many advantages such as high efficiency, high power factor, high power density, and high reliability. The module selects the three-phase AC input method without a centerline. DC output voltages range from 250V to 750V ...

Industrial control circuit board capacitor damage fault characteristics and maintenance - Senlan Industrial control circuit board capacitor damage fault characteristics and maintenance - Senlan

Capacitor damage is the highest problem in electronic devices, especially electrolytic capacitors. Capacitor damage is manifested in: 1. Capacity becomes smaller, 2. Capacity is completely lost, 3. Leakage, 4. Short circuit. Electricity...

The correct wiring of the rail power supply The correct wiring of the rail power supply

The rail-rail power supply is a kind of switching power supply that is installed through the rail-type device, which is mainly used to monitor the voltage, current, temperature and other different aspects of the equipment, so that it can play a good maintenance effect. This switching power supply has a variety of different characteristics such as small size and light weight, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top