1. Please explain the maintenance function of the inverter?

(1) After detecting the abnormal situation, the correction action will be carried out automatically, such as overcurrent loss rate prevention, regeneration overvoltage stall prevention.

(2) After detecting the abnormality, the PWM control signal of the power semiconductor device is closed, so that the motor can park automatically. Such as regenerative overvoltage blocking, overcurrent blocking, semiconductor cooling fan overheating and instantaneous power failure maintenance.

                               Common problems in the use of inverter - Sunland inverter

2. What is regenerative braking?

If the motor decreases the command frequency during operation, the motor becomes an asynchronous generator and operates as a brake, which is called regenerative (electrical) braking.

3. Can regenerative braking get more braking force?

The regenerative energy from the motor is stored in the filter capacitors of the inverter. Due to the relationship between capacitor capacity and withstand voltage, the regenerative braking force of the general-purpose inverter is about 10%-20% of the rated torque. If the optional brake unit is selected, it can reach 50%-100%.

4. In the same factory, the large motor is moved together, and the inverter is stopped during work, why is this?

When the motor starts, it will flow through the starting current corresponding to the capacity, and the transformer on the stator side of the motor will experience a voltage drop. When the motor capacity is large, this voltage drop will also have a great effect, and the inverter connected to the same transformer will make an undervoltage or instantaneous stop judgment, so sometimes the maintenance function (IPE) will operate, resulting in aborted work.

5. What is variable frequency resolution? What's the point?

With regard to digitally operated frequency converters, the output frequency is given in stages, even if the frequency command is an analog signal. The smallest unit of this gradient is called the variable resolution. For example, if the resolution is 0.5Hz, then the top of 23Hz can be changed to 23.5 and 24.0 Hz, so the action of the motor is also followed by a step. This raises questions about the use of things like continuous coiling manipulation. In this case, if the resolution is about 0.015 Hz, and the difference between one step of the 4-stage motor is less than 1 r/min, it can be used to it.

6. Why does the maintenance function of the inverter work when the clutch is connected to the load?

When the clutch is connected to the load, at the moment of receiving the load, the motor changes sharply from the no-load condition to the area with a large slip rate, and the high current flow causes the inverter to overcurrent trip, and the inverter cannot operate.
More on that
The cause of vibration and noise in the inverter - Sunland inverter The cause of vibration and noise in the inverter - Sunland inverter

Generally speaking, the inverter will inevitably present some problems during operation, such as oscillation and noise, which are common problems in VFD operations. So, what causes oscillation and noise in VFDs? What is the solution to these problems? Here are the causes of VFD oscillation and noise ...

Precautions for starting electrical equipment after a long holiday - Senlan Precautions for starting electrical equipment after a long holiday - Senlan

1. Do a good job of moisture-proof operations, clean up water and oil stains on site, insist on the boring environment of electrical equipment, and pay attention to preventing the inverter from being exposed. 2. Do a good job of maintenance and maintenance, take advantage of the shutdown for maintenance, clean the frequency conversion dust, and clean the frequency conversion air duct; Tighten the frequency conversion cable joint to prevent loosening, ...

Inverter with no-load operation and commissioning - Senlan Inverter with no-load operation and commissioning - Senlan

(1) Set the power of the motor, the number of pole pairs, and check the operating current of the inverter. (2) Set the maximum output frequency and base frequency of the inverter and set the torque characteristics of the motor. Pressure/Frequency (V/F) Operators ...

How to carry out electrical system commissioning quota? ——Sunland inverter How to carry out electrical system commissioning quota? ——Sunland inverter

The commissioning of the electrical system refers to the commissioning of the entire high and low voltage system. The power supply commissioning of civil electrical projects such as general residences, schools, office buildings, hotels, and shops shall be carried out in accordance with the following provisions: (1) About the commissioning of the belt in the distribution room ...

Control the hovering function operation and principle of the inverter - Sunland inverter Control the hovering function operation and principle of the inverter - Sunland inverter

How does the hovering function of the inverter work? When the speed of the asynchronous motor is 0, the encoder response is meaningless, and it needs to be converted to V/F control, and the frequency is set to 0; The voltage is set to 0 speed at which the motor promises to withstand the current at the moment ...

How to choose an inverter - Hope Sunland How to choose an inverter - Hope Sunland

The selection of the inverter should be considered according to the type of controlled object, speed regulation scale, static speed accuracy, starting torque, etc., so that it can be easy to use and economical together with meeting the process and production requirements. According to the different forms of devices, it can be divided into four types, which can be divided into four types according to the controlled motor power and field device ...

Misunderstanding of the use of inverter - Senlan inverter Misunderstanding of the use of inverter - Senlan inverter

Poor choice This should be the situation that friends have encountered the most in the Z, the situation of large horse-drawn carts and small horse-drawn carts is everywhere. The big horse-drawn trolley is not bad, at least there is no big problem in use, the most investment has been added, and the equipment can still operate normally; But the small horse-drawn cart ...

Frequency conversion speed regulation of several special motors - Senlan frequency converter Frequency conversion speed regulation of several special motors - Senlan frequency converter

A. Wound rotor asynchronous motor The rotor winding of the wound rotor asynchronous motor is a set of three-phase windings with star connection. The end points of the three-phase winding are connected to the three collector rings, which are connected to the brushes and the external resistor (for starting or speed regulation) through the collector rings. Select inverter ...

Senlan inverter selection points Senlan inverter selection points

1. Select the inverter according to the load characteristics, such as the load is constant torque load, you can choose Siemens MM440 inverter, ABB ACS800 series inverter, etc.; If the load is a fan or pump load, you can choose Siemens MM430 inverter, ABB ACS510 series inverter, etc. 2、 ...

Inverter to avoid load shock - Sunland Inverter to avoid load shock - Sunland

In the process of operation, try to ensure that the inverter (hereinafter referred to as -VFD) has a satisfactory acceleration and deceleration time, and the VFD has its own soft start function when starting or accelerating; When the power is shut down or the speed is slowed down, it has the function of soft shutdown. Add acceleration and deceleration times as much as possible within the range promised by the device. When the device requires ...

Sunland inverter control panel button function Sunland inverter control panel button function

1. The "FUNC/DATA" key is a programming key, press this button once to convert the operation mode, and press it again to read and write the function code; 2. The "SET/>>" button is the display switch and shift key, press this key to switch the display content, and press it again to ...

Commonly used motor protection method - Hope Sunland Commonly used motor protection method - Hope Sunland

1. Install a reactor at the output of the inverter: This method is the most commonly used, but it should be noted that this method has a certain effect on shorter cables (less than 30 meters), but sometimes the effect is not ideal. 2. In the inverter ...

Inverter remote control wiring method - Senlan Inverter remote control wiring method - Senlan

1. Connect X (switching input) drive terminal to control the inverter start-stop/forward and reverse rotation; 2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control active conditioning frequency) 3. Other DO (switching output) is used for transmission ...

Fault signal processing method of frequency converter Fault signal processing method of frequency converter

(1) Check whether the motor is hot. If the temperature rise of the motor is not high, you should first check whether the size of the load, the acceleration and deceleration time, and the running cycle time are reasonable, and correct the V/F characteristics, and check whether the electronic thermal protection function of the inverter is preset reasonably, such as the inverter.

Introduction to the classification method of inverter maintenance faults Introduction to the classification method of inverter maintenance faults

1. How to distinguish between heavy faults and light faults According to the occurrence time of inverter faults, we can divide the types of faults into two categories: sudden faults and intermittent faults: (1) The sudden fault of inverter repair refers to the failure of the equipment when it is running, without warning.

Sunland Shore Power Innovation - The world's first high-voltage water-cooled four-quadrant shore power system rolled off the production line Sunland Shore Power Innovation - The world's first high-voltage water-cooled four-quadrant shore power system rolled off the production line

In order to thoroughly implement the spirit of General Secretary Xi Jinping's important instructions that the economic power must be a maritime power, a shipping power, economic development, a strong country, and transportation, especially shipping, and the implementation of the outline for the construction of a transportation power, the port ship shore power system has become the standard for green ports.

Senlan inverter chemical industry air compressor application precautions Senlan inverter chemical industry air compressor application precautions

1. Due to the large moment of inertia of the air compressor, the capacity of the inverter should be determined according to the specific working conditions and the operating current of the site. 2. The pressure sensor should be in the pressure change is not relative...

Inverter control method for motor - Senlan Inverter control method for motor - Senlan

1. U/f stable control U/f control is to change the voltage of the motor power supply together with changing the frequency of the motor power supply, so that the magnetic flux of the motor is kept constant, and the efficiency and power factor of the motor do not decrease within a wide range of speed regulation. Because it is to control the voltage and frequency ...

The drive panel does not display fault analysis The drive panel does not display fault analysis

1. The rectifier module is damaged It is usually caused by grid voltage or internal short circuit. In the case of excluding internal short circuits, the rectifier bridge is replaced. 2. The inverter module is damaged It is usually caused by damage to the motor or cable and the failure of the drive circuit. After repairing the drive circuit, ...

Calculation method of braking resistance and power of inverter - Sunland inverter Calculation method of braking resistance and power of inverter - Sunland inverter

(1) Brake usage rate ED% Brake usage rate ED%, that is, the brake usage rate in the clarification book ED%. The brake utilization rate ED% is said to be the deceleration time T1 divided by the deceleration cycle T2, and the brake utilization rate is mainly to allow the braking unit and the brake resistance to have sufficient time to dissipate ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top