In order to achieve a more efficient and controllable operation of the motor, and avoid the waste of power of the motor drive system, the inverter came into being. However, due to the wide variety of motor load types, the functional requirements for the equipped inverter are also different, so how to choose the right inverter for the motor? These are all questions before engineers.
The inverter principle is applied to the inverter principle and electronic information technology, and the output power transmission component of the AC motor is manipulated according to the change of the frequency and amplitude value of the alternating current.
The inverter should be considered according to the type of control target, static speed accuracy, speed regulation range, starting torque and other factors, to consider the selection of the corresponding model of the inverter. It is easy to use and economical while meeting the requirements of process and production. Choosing the right inverter for the entire motor system is a headache.
Strictly speaking, the size of the rated power of the motor is not directly related to the selection of the inverter. The model selection of the inverter is generally based on the load type of the motor driver, such as cranes, cranes, metal drawing equipment, mining and crushing and other high-load equipment must be two specifications larger than the motor.
The second is to depend on the rated current of the motor. The rated output current of the inverter is greater than the rated current of the motor. Ordinary fans and pumps can be matched with light-load F-type inverters 1:1; The general mechanical class can be matched with the heavy-duty G-type inverter 1:1; Roots blower and submersible pump should choose the same power and heavy load inverter... There is also the influence of altitude and temperature, etc.
When the high-power motor starts, the inverter can achieve the advantages of smooth motor starting current and no impact. The inverter is also a smart device in the speed control circuit. The speed adjustment is stable. The distance of the force is equal. AC contactors, which are common in electromagnetic starters, will produce a large inrush current when starting directly. For motors with high equipment losses. Both 400 volts and 18.5 kilowatts can be used, but the inverter is a little more expensive.
When selecting the inverter, the actual current value of the motor should be used as the basis for selecting the inverter, and the rated power of the motor can only be used as a reference. In addition, the fact that the inverter output contains a large number of higher harmonics should be fully considered, which will reduce the power factor and efficiency of the motor.
Therefore, using an inverter to supply power to the motor has a 10% increase in motor current and a 20% increase in temperature rise compared to supplying power to the commercial grid. Therefore, when selecting motors and inverters, taking this situation into account, it is necessary to leave a margin in order to prevent the temperature from rising too high and affecting the life of the motor.
The overload torque of YZ and YZR series motors is generally 212-218 times. In order to give full play to the load capacity of the motor and improve the safety performance of the potential energy load equipment, the overload capacity of the inverter-motor system must be guaranteed to be 212-218 times after the inverter is used for control.
Since the overload capacity of the ordinary inverter at 150% of the rated load is normal for 1 minute, the instantaneous overload torque can only reach 180%-200%, so it is necessary to increase the capacity of the inverter to improve the instantaneous overload capacity of the inverter-motor system.
As long as the capacity of the inverter is increased by about 20%, the instantaneous overload capacity of the inverter motor system can be increased by 210-214 times, which can basically be satisfied. Therefore, please choose an inverter with a rated capacity of more than 120% of the rated capacity of the motor, that is, the capacity of the inverter is increased by one level.
|
More on that
|
Introduction to the advantages and disadvantages of ultrasonic level gauges
Ultrasonic level gauge is a non-contact instrument that uses the principle of echo ranging. The echo ranging principle is also known as the travel time or travel time measurement principle. It emits energy waves through a device that can emit energy waves (generally pulse signals), and the energy waves are reflected when they encounter obstacles, and are reflected by a ...
|
|
The inverters we "installed" together in those years
1. First confirm the installation environment of the inverter
I. Operating temperature. The inverter is a high-power electronic component, which is very susceptible to the influence of working temperature, and the product is generally required to be 0-55 °C, but in order to ensure the safety and reliability of the work, it should be considered to leave room for use, and it is good to control it at 4 ...
|
|
How to set the motor characteristic parameters of the inverter - Fuji Motor
Do you know how to set the motor characteristics of the inverter-controlled mechanical equipment? Next, Sanke Inverter will introduce this aspect for you through the following content.
1. Parameters to be set for the motor
When the inverter (hereinafter referred to as the -VFD) is in the "vector control" (F0-03=1) mode ...
|
|
Fuji Electric has completed a major upgrade of the FRENIC-MEGA series of general-purpose inverters
Fuji Electric Corporation (President: Tsuhiro Kitazawa, Head Office: Shinagawa-ku, Tokyo) is pleased to announce that it has completed a major upgrade of its FRENIC-MEGA series of general-purpose inverters in order to improve power at its production sites.
※Echo characteristics: output signal ...
|
|
Fuji Electric and PetroChina jointly established Kunlun Fuji Instrument Company
On the morning of June 1, the opening ceremony of Wuxi Kunlun Fuji Instrument Co., Ltd. was held. Gong Peixing, chairman of the Wuxi CPPCC, was invited to attend the ceremony, and some responsible comrades of the new district participated in the event.
In his speech, Chairman Gong said that the Wuxi Municipal Government and the New District Management Committee will continue to support...
|
|
Fuji Electric - How to deal with inverter interference
In the field, the interference of the frequency converter is more frequent and more serious, and even causes the control system to be unable to be put into use.
The operating principle of the inverter is destined to produce strong electromagnetic interference.
The inverter includes a rectifier circuit and an inverter circuit, and the input alternating current passes through the rectifier circuit and the flat wave.
|
|
Fuji Electric China will attend the 17th China International Environmental Protection Exhibition
On June 12, 2019, the 17th China International Environmental Protection Exhibition (CIEPEC2019) will be held at the China International Exhibition Center (Jing'an Zhuang Pavilion) in Beijing. More than 700 domestic and foreign exhibitors gathered together to showcase their environmental protection technologies and products. ...
|
|
Current status and outlook of Fuji Electric's power generation plant business
Fuji Electric has set forth its management philosophy of "Contributing to a Rich Society, Challenging the Limits of Creativity, and Developing in Harmony with the Natural Environment," and one of the pillars of its management policy is to contribute to the sustainable development of society through energy and environmental businesses.
This article will focus on the energy sector ...
|
|
The permissible current of the inverter is inversely time-bound with the process time
In the process of motor starting (acceleration), the motor should not only bear the load torque of steady speed operation, but also bear the acceleration torque, if the production machinery has no special requirements for the starting (acceleration) time, the starting (acceleration) time can be appropriately extended to avoid the peak current. If the production machinery is ...
|
|
Inverter to DCS Interference Handling Solution - Fuji Electric
The signal of the catalyst feed control valve of a company's DCS system (distributed control system) intermittently appears OOP (output signal line break) alarm, and the control valve is fully opened instantly, resulting in abnormal fluctuations in catalyst flow, which seriously affects the safe and stable operation of the device.
Fault cause analysis and treatment
...
|
|
Fuji Electric exhibited at PCIM Asia
On June 28, 2016, the three-day Shanghai International Power Components and Renewable Energy Management Exhibition (PCIM Asia) was grandly opened at the Shanghai World Expo Exhibition & Convention Center. Focusing on renewable energy technology, Fuji Electric (China) Co., Ltd. brought new products "Four Beauties" to the exhibition, which were Fuji ...
|
|
Fuji Electric joined hands with students from Zhejiang University to carry out environmental protection activities on road surfaces in Hangzhou
Fuji Electric's CSR can be seen as the implementation of the "Management Philosophy" and "Management Policy", which means that through energy and environmental business, we contribute to the resolution of social issues, maximize the positive impact of corporate activities on society and the environment as a whole, and prevent or reduce negative impacts.
|
|
Application of Fujifilm ultrasonic flowmeter in water supply
With the increasing shortage of water resources, the requirements of water supply enterprises for the metering performance of water meters are gradually increasing. In order to meet the measurement requirements of the water supply industry, various metering instruments have been continuously improved, from the traditional mechanical water meter to the electronic water meter. In recent years, electronic technology, computer technology and network communication technology ...
|
|
The Water Resources Bureau uses Fuji imported portable ultrasonic flowmeter for measurement
At present, the measurement of production water of enterprises is mostly the on-site installation of electromagnetic flowmeters or fixed ultrasonic flowmeters by local water conservancy bureaus as the measurement eyes, and they always keep an eye on the water used by enterprises to protect the use of public resources and eliminate waste.
In stationary electromagnetic flowmeters or stationary ultrasonic flowmeters ...
|
|
The trend of FUJI ultrasonic flowmeters replacing electromagnetic flowmeters
Of the nine waterworks in Berlin's water supply system, Tegel's water supply has a long history. Since 1877, drinking water has been pumped from Lake Tegel on the west coast. Today, the plant uses 116 vertical wells and one horizontal filtration well to pump a total volume of 260,000 m3 of drinking water per day. ...
|
|
Helping Data Centers and Communication Base Stations Save Power The second-generation discrete SiC-SBD series is released
Fuji Electric Corporation (CEO, Director and President: Tsuhiro Kitazawa, Headquarters: Shinagawa-ku, Tokyo) is pleased to announce that the second-generation discrete SiC-SBD* series, a series of power semiconductors, has been released for sale. This product will help drive the ...
|
|
Fuji inverter - what is the role of frequency conversion speed regulation technology in the field of energy conservation and environmental protection?
The frequency conversion speed regulation function of the inverter (hereinafter referred to as -VFD) is to convert the three-phase power frequency (50Hz) AC power supply (or any power supply) into a three-phase AC power supply with adjustable voltage and frequency. Frequency conversion speed control device can also be sometimes called VVVF, which is mainly used to adjust AC motors (asynchronous or synchronous machines).
|
|
Fujifilm ultrasonic flowmeter working principle and installation and commissioning
1. The working principle of Fujifilm ultrasonic flowmeter
A complete set of Fujifilm ultrasonic flowmeter is composed of ultrasonic generator, ultrasonic receiver, electronic circuit, flow display, accumulation system and other structures. The principle of ultrasonic flowmeter is shown in Figure 1.
As you can see from Figure 1, ...
|
|
Irrigation area remote monitoring water flow operation management scheme Fujifilm ultrasonic flowmeter application
In order to solve the problems of inaccurate metering and billing, difficult collection of water charges, and serious waste of water resources in agricultural irrigation water, modern automatic control, radio frequency triggering and other technologies are used to achieve the goal of paying the fee before using water, charging according to the quantity, automatic metering, and automatic opening and closing of the pump.
|
|
Fujifilm Inverter - How to Eliminate Inverter Electromagnetic Interference?
The source of AC converter interference comes from interference from the external power grid.
Harmonic interference in the power grid mainly interferes with the frequency converter through the power supply of the frequency converter. There are a large number of harmonic sources in the power grid, such as various rectifier equipment, AC and DC interchange equipment, electronic voltage adjustment equipment, nonlinear loads and lighting equipment.
|
|