For the first time to use Mitsubishi inverter, the operation command and frequency command equipment may not be familiar, especially related to the setting of domestic inverter, the two parameters are separated. Mitsubishi's, on the other hand, are collectively referred to as the form of operation.

                               Mitsubishi inverter forward and reverse parameter adjustment

There are a total of 7 forms of operation to select the content, including frequency instructions and launch instructions, from which it is found that there are external, PU and network three forms mixed together, one is confusing, let's briefly introduce these three forms:

1. External form: use external terminal control, set potentiometers and switches externally to operate;

2. PU form: using the operation panel and parameter unit to input the launch command and frequency command;

3. Network form or NET operation form: RS-485 communication or communication option control through PU interface. Now we can probably understand, for example, the local control of the inverter, we can choose 0 external/PU switching form or 1 fixed PU operation form. If you want external terminal control, you can select the form 123.

According to the above description of the setting operation form, the forward rotation terminal is STF, and the rotary terminal is STR, which is tacit, and the terminal definition parameters do not need to be changed by ourselves. If the direction of the motor is not the same in practice, you can change the two terminals, modify the terminal definition, or replace the phase sequence of the output of the frequency device.

More on that
Mitsubishi PLC's communication inspection method Mitsubishi PLC's communication inspection method

When you are ready to communicate through AJ71QE71, perform a ping in MS-DOS format to check if the connection is correct before the Mitsubishi PLC's GPPW starts to communicate. The support communicates with the Weilun touch screen through the serial port. ...

Mitsubishi PLC control servo motor method Mitsubishi PLC control servo motor method

1. The transistor output type of the FX series generally sends pulses to the servo through the output point of Y0, Y1 or the positioning module, and the speed and direction of the servo depend on the frequency and direction of the pulse in your program. Mitsubishi FX3U series ...

How does Mitsubishi PLC work? How does Mitsubishi PLC work?

1. A scanning cycle is divided into input sampling, program fulfillment, and output rewriting. 2. Each scan process. The convergence samples the input signal. The convergence rewrites the output signal. 3. The inner ...

Advantages and disadvantages of different output types of PLC – Mitsubishi Advantages and disadvantages of different output types of PLC – Mitsubishi

The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types? (1) Transistor output: The big advantage is that it is accustomed to high-frequency action, and the echo time is short, generally about 0.2ms, but ...

Advantages of Mitsubishi Electric fresh air system Advantages of Mitsubishi Electric fresh air system

Mitsubishi Electric's fresh air system realizes indoor ventilation, but of course, we can't just replace the outdoor air into the room, a good fresh air should filter the harmful substances in the air, so that the air entering the room is not only fresh, but also clean and harmless. ...

Mitsubishi Electric appeared at the 2021 China Smart Expo Mitsubishi Electric appeared at the 2021 China Smart Expo

From August 23 to 25, 2021, the 2021 China International Intelligent Industry Expo (hereinafter referred to as the Smart Expo) was held in Chongqing International Expo Center. Mitsubishi Electric (China) ...

Mitsubishi servo drive system requirements Mitsubishi servo drive system requirements

Servo drive system requirements 1. Wide speed regulation 2. High positioning accuracy 3. Satisfactory transmission rigidity and high speed stability 4. Fast response, no overshoot In order to ensure productivity and processing quality, in addition to the requirement of high positioning accuracy ...

There is no self-locking reason for the Mitsubishi servo motor to be turned on There is no self-locking reason for the Mitsubishi servo motor to be turned on

In some cases, when the user first touches the use of the Mitsubishi servo motor, it may appear that the Mitsubishi servo motor is not self-locking after it is ready! So, what is the reason for this? And how to deal with it? ...

Mitsubishi tells you what IGBT is Mitsubishi tells you what IGBT is

Mitsubishi Electric IGBT is the English word Insulated Gate Bipolar Transistor, which means insulated gate bipolar transistor in Chinese. Functionally, IGBT is a circuit switch, and the advantage is that it uses electricity.

PLC Programming Recommendations – Mitsubishi PLC PLC Programming Recommendations – Mitsubishi PLC

1. When the PLC and the host computer (or touch screen) form a monitoring system, there are many hours on the screen that require "manual", "active" and other control forms (generally more than one). In the program, you can use the "MOV" command. For example, when selecting "manual", the constant 1 MOV will be changed to a ...

Anti-interference measures for PLCs and touch screens - Mitsubishi PLC Anti-interference measures for PLCs and touch screens - Mitsubishi PLC

1. Select the power supply with excellent performance and press the disturbance introduced by the power grid The power supply of the PLC controller is powered by a non-power line, and is powered by a special line directly led by the main bus of the low-voltage distribution room. Isolation transformer should be selected, the transformer capacity should be 1.2-1.5 times larger than the actual need, and can be used in isolation...

The reason why the computer programming software and the Mitsubishi PLC cannot communicate The reason why the computer programming software and the Mitsubishi PLC cannot communicate

What is the reason why the programming software on the computer and the Mitsubishi PLC cannot communicate? How do I set the port of the communication line? There are several reasons why communication may not be available: 1. It may be that the PLC is not energized; 2. Programming software to create ...

Capacitive action in Mitsubishi inverters Capacitive action in Mitsubishi inverters

Introduction to the names and effects of capacitors in different circuits Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many names, understand ...

Mitsubishi drive functions and functions Mitsubishi drive functions and functions

1. Control the start, stop, speed and so on of the servo motor; 2. Carry out various maintenance on the motor (overload, short circuit, undervoltage, etc.) 3. React to external signals and control servo motors (position, speed, torque) through internal PID conditioning; ...

The protection function of the inverter to the motor - Mitsubishi The protection function of the inverter to the motor - Mitsubishi

The inverter is the control equipment for the operation of the motor, and it has a certain maintenance function for the motor. Most of the inverter appliances have functions such as overvoltage, overcurrent, undervoltage and overload maintenance. Overcurrent maintenance function. In any link of motor acceleration, deceleration and constant speed operation, ...

Mitsubishi FX1N switching power supply fault repair Mitsubishi FX1N switching power supply fault repair

Problem description: The power supply of the Mitsubishi FX1N-60MR-001 has no display (the safety guard, filter, temperature protection element, and rectifier are damaged). Inspection and repair: After the PLC is connected to the power supply, the power indicator (POWER light) does not light up.

Mitsubishi inverter pre-use debugging steps Mitsubishi inverter pre-use debugging steps

1. No-load energizing test of Mitsubishi inverter. 1. Ground the ground terminal of the Mitsubishi inverter. 2 Connect the power input terminal of the Mitsubishi inverter to the power supply through the leakage maintenance switch. 3 Check whether the factory display window of Mitsubishi inverter is normal, if it is not correct.

What are the main factors of interference in Mitsubishi PLC system? What are the main factors of interference in Mitsubishi PLC system?

(1) Radiative dry disturbance from space The radiated electromagnetic field (EMI) in space is mainly caused by power networks, transient processes of electrical equipment, lightning, radio broadcasting, television, radar, frequency induction heating equipment, etc., generally known as radiation disturbance, and its dispersion is extremely chaotic. ...

Mitsubishi FX series PLC error command and solution Mitsubishi FX series PLC error command and solution

1. Error message: NO ERROR--No abnormal error occurs Abnormal content and cause: No abnormal occurrence Solution: Check whether the cable connection between the host and the I/O expansion base/module is normal 2. Error message: ...

Fault analysis of Mitsubishi inverter OC1 and OC3 Fault analysis of Mitsubishi inverter OC1 and OC3

Mitsubishi inverter OC (overcurrent problem) will be caused by the following reasons, taking A500 series inverter as an example: 1). Caused by improper parameter setting problems, such as time setting is too short. 2). ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top