Flame retardant rubber sheathed cable
1. Use
This product is a series of mining rubber sheathed flexible cables. It is suitable for power connection of shearers and similar equipment devices with rated voltage Uo/U of 1.9/3.3KV and below. It is mostly used in coal mines.
2. Conditions of use
The long-term permissible operating temperature of the wire core is 65°C, and the minimum bending radius of the wire is 6 times the diameter of the cable. Yellow-sheathed cables must not be exposed to sunlight for long periods of time.
Nuclear-grade cables
Scope of application
· This product is suitable for control and signal connection cables used in the control system network of nuclear power plant rated voltage Uo/U is 0.6/1kV.
· The allowable long-term working temperature of the cable conductor is 90 °C, and the maximum temperature of the cable conductor does not exceed 250 °C when short circuit, and the duration does not exceed 5 seconds.
· The ambient temperature when laying the cable should not be lower than 0°C.
· The allowable bending radius when laying the cable is:
— Unarmoured cables, which should not be less than 6 times the diameter of the cable
— Cables with armor or copper strip shielding results should not be less than 12 times the diameter of the cable
— Flexible cables with shielded structures should not be less than 6 times the diameter of the cable.
· When the long-term allowable working temperature of the conductor is not greater than 90 °C, the identification life of the cable is not less than 40 years.
· The finished cable shall meet the requirements of Class A bunching combustion test specified in the GB/T18380.3 standard.
· Smoke density of finished cable: light transmittance is not less than 70%.
· radiation resistance: 25×104Gy
· Halogen-free: When non-metallic materials are burned, the acidity of the evolved gas (expressed by PH value) should be greater than 4.3; the conductivity should not be greater than 10μS/mm.
Bare wires and bare conductor products
The main characteristics of this type of products are: pure conductor metal, no insulation and sheath layer, such as steel core aluminum stranded wire, copper-aluminum busbar, electric locomotive line, etc.; The processing technology is mainly pressure processing, such as smelting, calendering, drawing, stranding/pressing stranding, etc.; The products are mainly used in suburbs, rural areas, user mainlines, switch cabinets, etc.
Power cables
The product is mainly used in the transmission of strong electric energy in the power generation, distribution, transmission, transformation and power supply lines, with large current (tens of amperes to thousands of amperes) and high voltage (220V to 500kV and above).
Communication cables and optical fibers
With the rapid development of the communication industry in the past 20 years, the products have also developed at an astonishing speed. From simple telephone and telegraph cables in the past, it has developed into thousands of pairs of telephone cables, coaxial cables, optical cables, data cables, and even combined communication cables. The structural size of this type of product is usually small and uniform, and the manufacturing accuracy is high.
Magnet wire (winding wire)
It is mainly used for various motors, instruments, etc.
Flexible fireproof cables
1. Excellent fire performance, fire resistance grade not only meets the international GB12666.6A class 950 °C 90min, but also meets the requirements of class A 650 °C 3h B class 750 °C 3h C class 950 °C 3h in United Kingdom BS6387-1994 At the same time, it can also withstand water spray and mechanical impact in combustion.
2. The continuous length is long, whether it is a single-core or multi-core cable, and the length can meet the needs of the power supply length, and the limit length can reach 2000m.
3. The cross-section of the single-core cable can reach 1000mm2, and the cross-section of the multi-core cable can reach 240mm2.
4. It is flexible, the cable can be coiled on the cable reel, and its bending radius ≥ 20D, and D is the outer diameter of the cable.
5. It is smokeless and non-toxic when burning, and the insulation is made of inorganic materials "non-combustible body", which will not produce any harmful gases during combustion, and will not cause secondary pollution, which can be called an environmentally friendly green product.
6. The cross-sectional capacity is too large, and the cable not only has a large cross-sectional flow but also has a large overload capacity. According to the wiring requirements, the surface temperature of the cable is usually ≤ 70°C. When it also does not come into contact with combustible building materials? The cable sheath temperature can reach 105°C. The fireproof cable is allowed to operate at a temperature of up to 250°C in case of overload.
7. Corrosion-resistant, organic insulated fire-resistant cables sometimes need to wear plastic pipes or iron pipes, which are easy to age and become brittle, and iron pipes are easy to corrode; The fireproof cable is a copper sheath that does not need to be threaded, and the copper sheath has good corrosion resistance.
8. There is no electromagnetic interference, and the fireproof cable is laid in the same shaft with the wires and cables such as signal and control. The fireproof cable is shielded by a copper sheath. Won't the signal? Interference is generated by the information transmitted by the control wires and cables.
9. Good safety, in addition to the normal power supply of the fireproof cable in the flame, start the fire extinguishing equipment to reduce the fire loss. At the same time, it is also particularly reliable for personal safety, its copper sheath is a good conductor, is the best grounding wire, and continuous to the full length of the cable, greatly improving the sensitivity and reliability of grounding protection.
10. Long service life, inorganic insulating material, high temperature resistance, and not easy to age, his life is many times higher than that of organic insulated cables, and its life can be equivalent to that of buildings under normal working conditions.
11. The transportation and installation of flexible fireproof cables include installation.
new products
The derivative/new products of wires and cables are mainly due to the requirements of different application occasions, application requirements, convenience of equipment and reduction of equipment costs, etc., and the use of new materials, special materials, or changing the product structure, or improving process requirements, or combining different varieties of products.
Different materials are used, such as: flame retardant cable, low smoke halogen-free/low smoke and low halogen cable, termite-proof, rodent-proof cable, oil/cold/temperature resistant cable, etc
Change the product structure, such as: fire-resistant cable, etc
Improve process requirements such as: medical cables, etc
Combination products such as: OPGW, etc
Easy to install and reduce equipment costs, such as: prefabricated branch cables, etc.
|
More on that
|
Rittal air conditioner alarm code parsing
1. A01 system message: open the cabinet door Rittal air conditioner Cause: the position of the door opening and closing is incorrect;
2. A02 system message: the temperature in the cabinet is too high: the refrigeration capacity is too low or small;
3. A03 System Message: Filter Monitoring Cause: Dirty Filter Diagnosis ...
|
|
Reliability ceiling - Rittal and the maritime industry talk about China's "ship talk"
The Age of Discovery, which began at the end of the 15th century, linked the world and was one of the most important historical steps in the process of human civilization.
In the 21st century, in the development trend of global interconnection and China's intelligent manufacturing, the shipbuilding industry has ushered in high-energy development prospects.
Smart ships, low...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the main technical parameters of the fuse?
Answer: A. Rated voltage, B. Rated current, C. Breaking capacity, D. Melting characteristics, E. Overvoltage.
What are the main products of low-voltage power distribution equipment?
Answer: Low-voltage distribution panels, switch cabinets, switch boards, lighting boxes, power boxes and electrical ...
|
|
Rittal cables – what are the common cable faults?
Wire surface marking - according to the national standard, the wire surface should have the manufacturer name, product model and rated voltage continuous marking. This is conducive to finding the manufacturer in time when problems occur during the use of wires, and consumers must pay attention to this when purchasing wires. At the same time consume ...
|
|
Rittal X Kongsberg | Smart ship "Wei" can be expected
Smart ships are a key area clearly supported by national policies. Driven by policy guidance and innovation, China has achieved phased results in the research and construction of smart ships. As the world's leading provider of enclosure systems, Rittal has a wide range of applications in the marine and port sectors.
|
|
Rittal Cables – the principle of selection of power cables
1. Selection of wire and cable models
When selecting wires and cables, it is necessary to consider the use, laying conditions and safety; For example, depending on the application, power cables, overhead insulated cables, control cables, etc. can be selected
According to the different laying conditions, the general plastic insulated cable can be selected ...
|
|
Introduction to the process characteristics of Rittal cabinets
1. The cabinet door is off the ground 25. 5mm
2、2. The 5mm thick mounting plate has 23mm wide U-shaped curved edges on both sides, which makes the mounting plate stronger and easier to handle
3. The three cable introduction cover plates at the bottom of the box can be replaced by each other, which is easy to move, easy to import cables, and easy to open holes into the line
...
|
|
Rittal cabinets – the operation process of power outages in low-voltage distribution cabinets
1. Normal power transmission operation process of low-voltage distribution cabinet:
1. All load switches are disconnected, confirm that the switches have at least one breakpoint;
2. Confirm that the power switch is in the disconnected position;
3. Send the power supply to the operation circuit, and the status indication is normal;
4. The incoming switch is - isolated ...
|
|
What are the application areas of Rittal cabinets – cabinet air conditioners?
Indoor unit: suitable for all kinds of control boxes, distribution boxes and electrical cabinets in machinery, electric power, chemical industry, textile machinery, automation equipment, instrumentation and other industries with high requirements for temperature and humidity. It can also be used to regulate temperature and humidity in small spaces.
Outdoor unit: suitable for outdoor general base station, outdoor ...
|
|
Rittal cables - the key points for the purchase of wires and cables
1. Look at the packaging, the wires of the national standard are often better, neat, and have a sense of quality when you hold them.
2. To open the package and take a look at the wires inside, the wire requirements of the national standard wire 1.5——-6 square are required to be skin thickness (insulation thickness) is 0.7mm, and too thick is non-standard.
|
|
Here's a quick overview of what products Rittal makes
Many customers don't know what products Rittal makes, so today I will simply classify Rittal products. Rittal products are mainly divided into 6 categories below 6
(1) Rittal control cabinet: small cabinet (here can also be subdivided polycarbonate cabinet PK, junction box KL, compact control box EB, ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
Which electrical equipment must be grounded or zeroed?
Answer: (1) The base and shell of generators, transformers, motors, high and low voltage electrical appliances and lighting appliances; (2) the secondary coil of the transformer; (3) the framework of the switchboard and the control panel; (4) Transmission device of electric equipment ...
|
|
With the Rittal VX SE freestanding cabinet, the possibilities are endless
How to make it simpler?
How can safety be paramount?
Still worried about not being able to reduce the cost of the system?
The most suitable cabinet system is just a dream?
You've got you covered – faster, safer, simpler, compatible, and versatile...
|
|
Rittal cabinet - judgment and treatment of sudden trip fault in operation of high-voltage switchgear
1) Fault phenomenon: The cause of this failure is the protection action. The high-voltage cabinet is equipped with protection against overcurrent, quick cut-off, gas and temperature.
2) Judgment method: The cause of the fault can be judged according to the relay card drop, remote signaling information, etc. After the action of gas and temperature protection in the high-voltage cabinet ...
|
|
Rittal Cables - Introduction to the performance characteristics of control cables
1. DC resistance: 20°C, 0.4mm copper wire, less than or equal to 148Ω/km, 0.5mm copper wire, less than or equal to 95Ω/km.
2. Insulation electrical strength: 1min 1kv between conductors does not break down, conductors and shields 1min 3kv do not break down
3. Insulation resistance: each core and the rest of the core ...
|
|
Rittal cables – what are the types of industrial wires and cables commonly used?
Industrial wires and cables include single-core wires and cables, rubber cables, shielded control cables, flame-retardant cables, fire-resistant cables, etc.
Single-core wire and cable
It means that there is only one conductor in the insulation layer, the common BV wire, and B represents the wiring; V stands for insulating polyvinyl chloride. Suitable for AC ...
|
|
How do I set the temperature of my Rittal aircon by remote control or panel?
The temperature setting of the Rittal air-conditioner can be operated via a remote control or a panel. The specific steps are as follows:
1. Turn on the power of the air conditioner and press the "on/off" button on the remote control or the power switch on the panel.
2. Press the "Mode" button on the remote control or the ...
|
|
Rittal cabinets – what are the steps in the cabling of the cabinet?
1. The first is to measure how long the line is.
According to the decision is to put the location of the distribution frame, and then combine the distance of the cable from the outside into the cabinet and so on to calculate how long the network cable needs to be put on the distribution frame and install the cabinet, so as to facilitate the overall cable management behind.
|
|
Five hidden details you didn't know about Rittal cabinets and common Q&A
Five details that are easy to overlook:
One of the hidden details: steel
The most basic thing of a cabinet is to look at the steel, the Rittal standard cabinet is made of section steel, there are many masters who understand the cabinet to understand, the steel plate must be thick, just knock it with your fingers. General ...
|
|
Rittal precision power distribution cabinet SPDR - make the data center "feel safe".
The power supply and distribution system of the data center is a system that provides stable and reliable power supply support for all the equipment that needs power supply in the computer room. The power supply and distribution system is like the heart of the human body for the entire data center system, and its importance is self-evident.