Rittal Cables - What are the main contents of cables?

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

1. SYV: solid polyethylene insulated RF coaxial cable, coaxial cable, radio frequency signal transmission in wireless communication, broadcasting, monitoring system engineering and related electronic equipment (including comprehensive coaxial cable)

2. SYWV (Y): physical foamed polyethylene insulated cable TV system cable, video (RF) coaxial cable (SYV, SYWV, SYFV) is suitable for closed-circuit monitoring and cable TV projects

SYWV (Y), SYKV cable TV, broadband network special cable structure: (coaxial cable) single oxygen-free round copper wire + physical foamed polyethylene (insulation) + (tin wire + aluminum) + polyvinyl chloride (polyethylene)

3. Signal control cables (RVV sheathed wire, RVVP shielded wire) are suitable for building intercom, anti-theft alarm, fire protection, automatic meter reading and other projects

RVVP: Copper core PVC insulated shielded PVC sheathed flexible cable, voltage 250V/300V, 2-24 cores Usage: instrument, meter, intercom, monitoring, control installation

4. RG: Physical foamed polyethylene insulated access network cable is used to transmit data analog signals in coaxial fiber hybrid network (HFC).

5. KVVP: PVC sheathed braided shielded cable, use: signal transmission, control and measurement of electrical appliances, instruments and power distribution devices

6. RVV(227IEC52/53): PVC insulated flexible cable, uses: household appliances, small power tools, instruments and power lighting

7. AVVR: PVC sheathed flexible cable for installation

8. SBVV: HYA data communication cable (indoor and outdoor) is used for the connection of telephone communication and radio equipment and the junction box wiring of the telephone distribution network

9. RV, RVP: PVC insulated cable

10. RVS, RVB: suitable for household appliances, small power tools, instruments, meters and power lighting connection cables

11. BV, BVR: PVC insulated cable, Uses: suitable for fixed wiring of electrical instruments and power lighting

12. RIB: speaker connection cable (audiophile cable)

13. KVV: PVC insulated control cable, use: signal transmission, control and measurement of electrical appliances, instruments and power distribution devices

14. SFTP: twisted pair, transmission telephone, data and information network

15. UL2464: computer cable

16. VGA: display cable

17. SDFAVP, SDFAVVP, SYFPY: coaxial cable, special for elevators

18. JVPV, JVPVP, JVVP: Copper core PVC insulated and sheathed copper wire, braided electronic computer control cable
Rittal Cables - What are the main contents of cables?

More on that
What factors need to be taken into account when choosing a Rittal cabinet – outdoor enclosure? What factors need to be taken into account when choosing a Rittal cabinet – outdoor enclosure?

1. Safety: As the carrier of electrical equipment, the outdoor cabinet must have excellent structural design, solid materials, and firm bottom fixation to meet the requirements of strong typhoons, strong rainstorms, and even strong earthquakes. At the same time, the cabinet should have anti-leakage, anti-short circuit, anti-cut and other requirements. 2. Rainproof and dustproof ...

The principle and use of Rittal cabinets The principle and use of Rittal cabinets

The Rittal cabinet principle Rittal is a Germany company that specializes in the manufacture of all kinds of cabinets. It is famous for its reasonable design and guaranteed quality. Now there are many imitations in China, and imitation Rittal is also popular. The working principle of the Rittal cabinet is to cut off the inrush current of the wire itself.

Rittal Nonwovens filter mats product description Rittal Nonwovens filter mats product description

Product Introduction Product name: Rittal Rittal Product Type: Rittal Non Woven Filter Mats Product Model: 3172.105 Spare filter mats for top-mounted fans, filter fans or thermoelectric coolers to protect control cabinet components from dirt, ash ...

Rittal innovates smart services to help build new infrastructure in the 5G era Rittal innovates smart services to help build new infrastructure in the 5G era

The construction of new infrastructure (new infrastructure) is a change in the upgrading and transformation of the industrial structure. As an important part of the new infrastructure, the data center provides a solid and extensive infrastructure guarantee for 5G, artificial intelligence, Internet of Things and other occupations. Rittal brings a new generation of infrastructure solutions ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

Which electrical equipment must be grounded or zeroed? Answer: (1) The base and shell of generators, transformers, motors, high and low voltage electrical appliances and lighting appliances; (2) the secondary coil of the transformer; (3) the framework of the switchboard and the control panel; (4) Transmission device of electric equipment ...

How to use the Rittal basic controller for cabinet air conditioning How to use the Rittal basic controller for cabinet air conditioning

Carefully push the decorative panel back onto the monitor until you hear it snap into place. · Reinsert the monitor into the panel or blind. · Reinstall the louver pane or panel onto the cabinet air conditioner. Reset the base controller The air conditioner in the cabinet emits a high ...

Alarm code analysis for Rittal chillers Alarm code analysis for Rittal chillers

1. E1: Temperature sensor failure 2. E2: Humidity sensor malfunction 3. E3: Compressor overload protection 4. E4: Compressor phase loss protection 5. E5: Compressor short circuit protection 6. E6: Compressor switch failure 7. E7: Fan failure ...

The Rittal enclosure model 6380.510 is designed to be ultra-slim and matched to the embedded devices The Rittal enclosure model 6380.510 is designed to be ultra-slim and matched to the embedded devices

Product Introduction Brand: Rittal cabinets Product model 6380.510 Aluminum box, strong thermal conductivity, excellent passive heat dissipation. For relatively small panels and control schemes. The ultra-slim design matches the embedded device and takes up almost no space. Type: Support ...

The Rittal TS8 system solution is designed to cope with extreme mining conditions The Rittal TS8 system solution is designed to cope with extreme mining conditions

Energy consumption planning continues to grow, and countries around the world have significantly increased the supply of low-carbon power such as nuclear, hydro, wind, and solar energy in order to achieve energy conservation and emission reduction. But now that natural resources are simply being exploited, what are the important developments of green energy that are lacking? The answer is: geothermal energy ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is the material of the busbar? A: Copper busbar, aluminum busbar and steel busbar. What is the significance of busbar coloring? Answer: It can increase the radiation capacity, which is conducive to heat dissipation, and the allowable load current can be increased by 12-15% after coloring. ...

Rittal cabinet - distribution cabinet installation method, installation process and precautions Rittal cabinet - distribution cabinet installation method, installation process and precautions

First, the construction process Equipment unpacking inspection→ equipment handling, → cabinet (plate), basic installation, → above the cabinet (plate), bus preparation, → cabinet (plate), secondary circuit wiring, → cabinet (plate) test adjustment, → power transmission operation acceptance Second, the construction process 1. Equipment unpacking inspection, installation ...

The Rittal plastic handle replaces the standard lock with or without a secure semi-circular cylinder The Rittal plastic handle replaces the standard lock with or without a secure semi-circular cylinder

Product Model 2485.100 Replace standard locks with or without a secure semicircular cylinder.   Type::C Color: RAL 9011 A note on the order number: Not suitable for AE 1018.600 Lock: Cylinder: No safety cylindrical cylinder ...

Rittal cabinets – the difference between racks, cabinets, and servers? Rittal cabinets – the difference between racks, cabinets, and servers?

1. a rack Rack: Installed in a standard cabinet, it is a functional server, so the standard cabinet is also called a "19-inch" rack. Rack is a more professional academic term, and most of the current policy documents mention "rack", and clarify the indicators such as single rack power and average shelf rate ...

Rittal! Guarding the cabinet system with a "core". Rittal! Guarding the cabinet system with a "core".

As the "guardian" of the cabinet, the lock system is also an important accessory choice in the cabinet system. Locking systems include fasteners, locks, keys, handles, and cylinders, among others. The lock cylinder refers to the module that is replaced for different locks and keys. 01. Personalized configuration ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is the role of a DC system in a substation? Answer: The DC system provides reliable DC power supply for control signals, relay protection, automatic devices and accident lighting in the substation, and also provides reliable operating power for operation. The reliability of the DC system has a significant impact on the ...

Rittal Temperature Control Portfolio – for new energy applications Rittal Temperature Control Portfolio – for new energy applications

With the continuous promotion of the dual carbon policy, the development of new clean energy such as wind power has been making great progress. China and United States are among the world's largest growing countries for wind energy equipment. Wind turbines typically need to operate reliably for more than 20 years to deliver electricity to people. To this end ...

Rittal Cables – what are the ways to lay wires and cables? Rittal Cables – what are the ways to lay wires and cables?

1. Buried laying The laying method of laying the cable immediately underground is called buried laying. The buried cable must be armored cable and anti-corrosion coating protection cable, and the bare cable cannot be buried. Generally, the depth of the cable trench shall not exceed 0.9m, and the buried laying shall be paved ...

Rittal Cables – What do you need to pay attention to when wiring industrial control cables? Rittal Cables – What do you need to pay attention to when wiring industrial control cables?

1. The weight of the cable in the industrial control cable drag chain should be evenly distributed, so as to avoid accidents caused by uneven weight during operation, and the principle of distributing the cable is that the heavier one is located on both sides and the lighter one is located in the middle. All industrial control cables must be securely fastened to one end of the energy chain, so that ...

The FR IT new product launch event organized by Rittal was held in Beijing The FR IT new product launch event organized by Rittal was held in Beijing

The "Eastern Data and Western Computing" project aims to promote the rational layout of data centers, optimize supply and demand, green intensification and interconnection, so that the computing resources in the west can more fully support the computing of data in the east and better empower the country's digital development.   IT infrastructure is an important ...

Rittal cabinets – the operation process of power outages in low-voltage distribution cabinets Rittal cabinets – the operation process of power outages in low-voltage distribution cabinets

1. Normal power transmission operation process of low-voltage distribution cabinet: 1. All load switches are disconnected, confirm that the switches have at least one breakpoint; 2. Confirm that the power switch is in the disconnected position; 3. Send the power supply to the operation circuit, and the status indication is normal; 4. The incoming switch is - isolated ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top