Commonly used motor protection method - Hope Sunland

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

1. Install a reactor at the output of the inverter: This method is the most commonly used, but it should be noted that this method has a certain effect on shorter cables (less than 30 meters), but sometimes the effect is not ideal.

                              Commonly used motor protection method - Hope Sunland

2. Install a DV/DT filter at the output end of the inverter: this method is suitable for occasions where the cable length is less than 300 meters, and the price is slightly higher than that of the reactor, but the effect has been significantly improved.

3. Install a sine wave filter at the output of the inverter: this method is ideal. In this case, the PWM pulse voltage is changed to a sine wave voltage, and the problem of spike voltage is thoroughly dealt with under the same conditions as the power frequency voltage in motor operation (no matter how long the cable is, it will no longer exhibit spike voltage).

4. Install the spike voltage absorber at the position of the interface between the cable and the motor: the defect of the first few methods is that when the power of the motor is large, the volume and weight of the reactor or filter are very large, and the price is higher, in addition, the reactor and the filter will lead to a certain voltage drop, affecting the output torque of the motor, and the use of frequency converter spike voltage absorber can overcome these defects.

More on that
Limit switch wiring method - hope Senlan Limit switch wiring method - hope Senlan

Limit switch is an electromechanical control element used to detect the direction of the movement of the machine or equipment, and send a signal when the specific position is in a specific direction to control the operation or stop of the equipment. It is often used in industrial production processes, such as CNC machine tools, conveyors, loading and unloading robots, etc. ...

Introduction to the classification method of inverter maintenance faults Introduction to the classification method of inverter maintenance faults

1. How to distinguish between heavy faults and light faults According to the occurrence time of inverter faults, we can divide the types of faults into two categories: sudden faults and intermittent faults: (1) The sudden fault of inverter repair refers to the failure of the equipment when it is running, without warning.

Damage and repair of internal electronic components of the inverter - Hope Sunland Damage and repair of internal electronic components of the inverter - Hope Sunland

1. Repair the damage of the inverter rectifier block The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block in the early production is mainly diode rectifier, and now some rectifier blocks choose the rectifier mode of thyristor (voltage regulation and frequency modulation inverter). Middle...

Application of Sunland inverter on gantry milling machine Application of Sunland inverter on gantry milling machine

The gantry milling machine is a machining equipment for processing larger workpieces, and its electrical control system includes two parts: the main transmission of the workbench and the logical control of the feed organization. Henan Jiaozuo Maike Company has a gantry milling machine, which has been used for many years since the 70s. The main drive of the operating table of the gantry milling machine is selected ...

The main circuit of the inverter application - Hope Sunland The main circuit of the inverter application - Hope Sunland

There is a circuit breaker QF and a communication contactor KM between the power supply and the inverter, when the inverter does not need to be used for a long time. or when the equipment is overhauled, the circuit breaker is used as an isolation switch, which can block the power supply and ensure the safety of maintenance. It has maintenance functions such as overcurrent and undervoltage. The main power of the inverter ...

Sunland inverter is used in Baotou steel water supply Sunland inverter is used in Baotou steel water supply

In recent years, with the development of power electronics skills, the frequency conversion speed regulation skills have been very mature, practice has proved that the use of frequency conversion speed regulation in fans, pumps and loads can save 20%-50% of the electric energy, and the use of frequency conversion speed regulation can bring the following advantages in the future, its biggest advantage is that it has ...

The inverter is regularly replaced with the device - Sunland inverter The inverter is regularly replaced with the device - Sunland inverter

1. Cooling fan As a prerequisite for ensuring the normal operation of the inverter, efficient and fast in-line cooling fans have become an indispensable conversion configuration of the inverter. Because of the wear of the internal bearings of the cooling fan and the reduction of the grease function in the process of application, the cooling of the fan.

Anti-interference measures in the application of Sunland inverter Anti-interference measures in the application of Sunland inverter

The main manifestations of the disturbance of the inverter in the application are: higher harmonics, noise and oscillation, load matching, heat generation and other problems. These disturbances are unavoidable, because the input part of the inverter is a rectifier circuit and the output part is an inverter circuit, both of which are made up of nonlinear components that play a switching effect.

Common problems in the use of inverter - Sunland inverter Common problems in the use of inverter - Sunland inverter

1. Please explain the maintenance function of the inverter? (1) After detecting the abnormal situation, the correction action will be carried out automatically, such as overcurrent loss rate prevention, regeneration overvoltage stall prevention. (2) After detecting the abnormality, the PWM control signal of the power semiconductor device is closed, so that the motor can park automatically. As...

Sunland inverter wiring standard Sunland inverter wiring standard

It is necessary to separate the signal line from the power line: when using analog signals for long-distance control of the inverter, in order to reduce the disturbance of the analog amount from the inverter and other equipment, please separate the signal line of the control inverter from the strong current circuit (main circuit and sequential control circuit). Inverter ...

Inverter-related knowledge - Senlan inverter Inverter-related knowledge - Senlan inverter

1. What does open-loop mean in the use of inverters? The speed detector (PG) is installed on the motor equipment in operation, and the speed response of the actual speed is sent to the control equipment, which is called "closed loop", and the speed detector that does not use PG is called "open loop". Most general-purpose drives are open-loop ...

Senlan inverter motor failure analysis Senlan inverter motor failure analysis

1. The motor slows down too slowly 1) If the deceleration time is set too long, reduce the deceleration time 2) Install a braking resistor 3) Add DC braking 2. The motor is overheated 1) The load is too large, and the practical moment has exceeded the ...

The inverter has an overvoltage phenomenon - Sunland inverter The inverter has an overvoltage phenomenon - Sunland inverter

Inverters often encounter a variety of problems during commissioning and use, during which overvoltage is the most common. After the overvoltage occurs, in order to avoid damage to the internal circuit, the overvoltage protection function of the inverter will work, so that the inverter will operate intermittently, resulting in the equipment can not be ...

How to choose an inverter - Hope Sunland How to choose an inverter - Hope Sunland

The selection of the inverter should be considered according to the type of controlled object, speed regulation scale, static speed accuracy, starting torque, etc., so that it can be easy to use and economical together with meeting the process and production requirements. According to the different forms of devices, it can be divided into four types, which can be divided into four types according to the controlled motor power and field device ...

Senlan SV1000 servo drive wearing parts replacement Senlan SV1000 servo drive wearing parts replacement

The wearing parts of the driver mainly include electrolytic capacitors for filtering and cooling fans, and their service life is closely related to the environment and maintenance of the operation. Depending on the operating moment, the user can determine whether a wear part needs to be replaced. Cooling ...

Precautions for using inverter - Sunland inverter Precautions for using inverter - Sunland inverter

A frequency converter (VFD) is an electrical energy control device that converts a power supply to another frequency by using the on-off effect of power semiconductor equipment. It can realize the soft start, frequency conversion speed regulation, improved operation accuracy, power factor, overcurrent/overvoltage/overload protection of AC asynchronous motor, etc.

The main circuit of the inverter application - Sunland inverter The main circuit of the inverter application - Sunland inverter

Between the power supply and the inverter, there is a circuit breaker QF and a communication touch device KM, when the inverter does not have to for a long time. or when the equipment is overhauled, the circuit breaker is used as an isolation switch, which can block the power supply and ensure the safety of maintenance. At the same time, the circuit breaker has maintenance functions such as overcurrent and undervoltage. The main circuit of the inverter can ...

Whether the front end of the inverter can be installed with a motor protector - Senlan Whether the front end of the inverter can be installed with a motor protector - Senlan

Frequency conversion speed regulation motor is generally selected 4-level motor, the fundamental frequency operation point is planned at 50Hz, the frequency 0-50Hz (speed 0-1480r/min) scale of the motor for constant torque work, the frequency of 50-100Hz (speed 1480-2800r/min) scale of the motor for constant power work, the whole speed regulation scale of (0 ...

The difference between a voltage signal and a current signal The difference between a voltage signal and a current signal

The general voltage in industry is 0... 5(10)V or current 0(4)... 20mA is used as an analog signal transmission method, and it is also a method often used by program control machines. So what is the difference between the transmission method of voltage and current, and when to choose what method, the following will be briefly introduced.

Inverter load type - Sunland inverter Inverter load type - Sunland inverter

(1). Constant torque load Different speeds, load resistance and torque base are stable. The output power is directly proportional to the rotational speed. Such as belt conveyors. (2). Constant power load Different speeds, stable load power base ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top