The control performance standard of the inverter cabinet
The control specifications of the inverter cabinet include reliability, accuracy, safety, environmental habits and versatility, etc., which are important guarantees to ensure the normal operation and safe production of the inverter cabinet control system.
Reliability specification: The control system should have high reliability and can be used for a long time.
|
|
The difference between "braking" and "parking" of the inverter - Senlan
There are two ways to park a drive.
One way is called "free parking". It is to quickly "power off" the motor, so that the motor can slide and park by its own inertia force (OFF2 parking);
The other way is called "braking parking". So this "brake parking ...
|
|
Inverter rectifier unit static detection mode
The method of judging the damage of a power element in the rectifier part is to manipulate the single conductivity of the rectifier element, and the positive and negative resistance values should not be consistent when the static value is general, and the specific method is as follows:
The three-phase bridge rectifier of the rectifier part may be two...
|
|
How far apart is the motor from the inverter - Senlan inverter
The supplier of the supporting equipment of the inverter reminds you that the voltage waveform output by the inverter is similar to a sine wave, but not a real sine wave. Its waveform contains a large number of harmonic components, especially the higher harmonics will increase the output current of the inverter, causing the motor winding to heat up, and produce oscillation.
|
|
Misunderstandings and solutions to the disadvantages of inverter application - Sunland inverter
Myth: The inverter selection only needs to consider the load power
When purchasing a frequency converter, many users usually only match the capacity of the frequency converter based on the power of the drive motor. In fact, the load driven by the motor is different, and the requirements for the inverter are also different.
...
|
|
How to choose an inverter - Hope Sunland
The selection of the inverter should be considered according to the type of controlled object, speed regulation scale, static speed accuracy, starting torque, etc., so that it can be easy to use and economical together with meeting the process and production requirements. According to the different forms of devices, it can be divided into four types, which can be divided into four types according to the controlled motor power and field device ...
|
|
Senlan SV1000 servo drive check before power-on
1) Oil circuit inspection: Open the safety valve to check whether there is any leakage in the oil circuit.
2) Line check: whether the R, S, T, PE on the input side of the driver, U, V, W, PE lines on the output side and the control line are corresponding.
3) Check whether the power supply voltage of the incoming terminal of the servo drive is normal ...
|
|
Failure of robot contactor and inverter - Senland
Robot contactors are noisy?
Cause:
It is likely that the joint contact surface of the contactor is uneven, and the surface is sand or rust. The result will constitute a phase loss, which will lead to the burnout of contactors, switch frequency conversion and other components.
Solution:
will control the ...
|
|
Fault signal processing method of frequency converter
(1) Check whether the motor is hot.
If the temperature rise of the motor is not high, you should first check whether the size of the load, the acceleration and deceleration time, and the running cycle time are reasonable, and correct the V/F characteristics, and check whether the electronic thermal protection function of the inverter is preset reasonably, such as the inverter.
|
|
PLC control belt conveyor soft start method
Belt conveyor is a kind of continuous conveyor, which is one of the main types of fixed or escorted cranes. Belt conveyor is the use of friction to convey the dynamic, with belts, steel belts, steel fiber belts and chemical fiber belts as a kind of compliance with the transmission of materials and traction operations.
|
|
Limit switch wiring method - hope Senlan
Limit switch is an electromechanical control element used to detect the direction of the movement of the machine or equipment, and send a signal when the specific position is in a specific direction to control the operation or stop of the equipment. It is often used in industrial production processes, such as CNC machine tools, conveyors, loading and unloading robots, etc.
...
|
|
Control the hovering function operation and principle of the inverter - Sunland inverter
How does the hovering function of the inverter work?
When the speed of the asynchronous motor is 0, the encoder response is meaningless, and it needs to be converted to V/F control, and the frequency is set to 0; The voltage is set to 0 speed at which the motor promises to withstand the current at the moment ...
|
|
Precautions for inverter wiring - hope Senlan
1. The inverter itself has strong electromagnetic disturbance, which will disturb the operation of some equipment, so we can add a cable sleeve to the output cable of the inverter.
2. The control line in the inverter or control cabinet is spaced at least 100mm, and the power cable is at least 100mm.
3. In the purchase of inverter ...
|
|
The eight forbidden areas of inverter control loop wiring - Senlan
1. The wires of the inverter control circuit should be strictly distinguished from the main circuit cable (power line) and placed separately. This will help prevent the inverter's control circuit from being disturbed by harmonics in the inverter's main circuit.
2. To separate the connection of the inverter from the terminals or contacts of other control circuits, ...
|
|
Hope Sunland inverter fault code
Er.ocb (1) Overcurrent at the moment of starting: There is a short circuit inside the motor
There is a short circuit in the motor wiring
The starting voltage is too high
Check the motor and wiring
Check the motor wiring
Seek service
Check the torque boost settings
...
|
|
The servo motor is connected to the wrong wire and causes a problem - Senlan
If the three power cables of the servo motor (SM) are not connected correctly, there may be no alarm in the static state. But as soon as the motor is operated manually or actively, the motor jumps off or starts to flutter, such as jumping when the speed is added too high, the system will issue generalized faults, etc.
|
|
Differential overhaul method of inverter - Senlan
For the dual requirements of anti-interference and galvanic isolation, the pre-circuit of the output current detection or voltage detection of the inverter usually uses the "matching" circuit of the linear optocoupler device and the differential amplifier to complete the transmission mission of the detection signal. The circuit of the differential amplifier is based on the current detection circuit ...
|
|
Sunland inverter overcurrent fault maintenance method
When the inverter current is too large, exceeding the limit value of the inverter, the maintenance circuit will produce action, so that the inverter trips and stops, and the phenomenon of repairing such inverter can be divided into energized ...
|
|
Damage and repair of internal electronic components of the inverter - Hope Sunland
1. Repair the damage of the inverter rectifier block
The damage of the inverter rectifier bridge is also one of the common faults of the inverter, the inverter rectifier block in the early production is mainly diode rectifier, and now some rectifier blocks choose the rectifier mode of thyristor (voltage regulation and frequency modulation inverter).
Middle...
|
|
Repair and maintenance of Sunland inverter
The input and output currents of the inverter contain many higher harmonic components. In addition to the lower harmonics that can constitute the reactive power loss of the power supply, there are many harmonic components with high frequencies. They will transmit their own energy in various ways, forming a positive impact on the inverter itself and other equipment.
|