The difference between "braking" and "parking" of the inverter - Senlan

Create Date: 2024-8-30 12:03:23|Source: Hope Sunland

There are two ways to park a drive.

One way is called "free parking". It is to quickly "power off" the motor, so that the motor can slide and park by its own inertia force (OFF2 parking);

The other way is called "braking parking". Then there are many ways to "brake parking". For example, OFF1 parking is braking according to a certain slope deceleration, or OFF3 "emergency braking" parking (parking according to the motor's maximum braking capacity).

                            The difference between "braking" and "parking" of the inverter - Senlan

Second, the means of braking and parking are: DC braking (that is, the power is given into a certain direct current); power braking (energy dissipation with resistors); hybrid braking (DC braking + power braking); Regenerative braking (injecting generating current into the grid); Mechanical braking of the brake.

Parking is divided into ramp wave parking and free parking (fast parking is also ramp wave parking, but the ramp wave is steeper).

Braking also includes mechanical braking (such as brake brake), energy consumption braking (braking resistance, reverse braking, DC braking, etc.), feedback braking, etc. Whether braking is required is related to the working condition of the motor, and braking needs to be used when the required parking time is less than the free parking time when the oblique wave is parked; There are times when braking is also required when the motor is working properly, such as when the hook is lowered.

In the drive system composed of power grid, inverter, motor and load, energy can be transmitted in both directions. When the motor is in the working form of the motor, the electric energy is transmitted from the power grid to the motor through the inverter, and is converted into mechanical energy to drive the load, and the load thus has kinetic energy or potential energy; When the load releases these energies in order to change the motion conditions, the motor is driven by the load and enters the working form of the generator, converting the mechanical energy into electrical energy and feeding back to the front-stage inverter. (http://www.diangon.comThis feedback energy is called regenerative braking energy and can be fed back to the grid by the inverter, perhaps in the braking resistor on the inverter's DC bus (energy braking).

Occasions when braking energy is generated

1. The process of decentralization of heavy objects of lifting equipment

2. Rapid deceleration process of large inertia loads

More on that
The cause of the leakage problem of Sunland inverter The cause of the leakage problem of Sunland inverter

1. The cause of inverter leakage According to the inverter to control the operation of the motor, the three-phase electricity is supplied to the inverter bridge (IGBT) through the filter capacitor through the rectification, and then the operation of the motor is controlled by the three-phase electricity with adjustable output frequency and voltage of the inverter. We all know that the three-phase stator winding of the motor ...

The reason for adding a frequency converter to the crane control system - Senland The reason for adding a frequency converter to the crane control system - Senland

Prior to the introduction of frequency converters, overhead crane operators operated the cranes using contactor-based controls. For low-cycle cranes, the system is equipped with a single or two-speed motor. For cranes with higher load cycles, they use so-called wound rotor motors. ...

How far apart is the motor from the inverter - Senlan inverter How far apart is the motor from the inverter - Senlan inverter

The supplier of the supporting equipment of the inverter reminds you that the voltage waveform output by the inverter is similar to a sine wave, but not a real sine wave. Its waveform contains a large number of harmonic components, especially the higher harmonics will increase the output current of the inverter, causing the motor winding to heat up, and produce oscillation.

The basic requirements of VFD installation design - Sunland inverter The basic requirements of VFD installation design - Sunland inverter

(1) The VFD should be installed in the control cabinet. (2) The VFD is best installed in the center of the control cabinet; The VFD It should be vertically installed with the top and bottom protected from large parts that may obstruct the exhaust and intake. (3) VFD control cabinet or partition, or the upper and lower parts of the necessary device ...

Inverter with no-load operation and debugging - Hope Sunland Inverter with no-load operation and debugging - Hope Sunland

The following four steps are very important for the commissioning of the inverter with the machine (i.e., connected to the motor) and no-load (i.e., the motor without load). (1) Set the power of the motor, the number of pole pairs, and check the operating current of the inverter. ( ...

The cause of vibration and noise in the inverter - Sunland inverter The cause of vibration and noise in the inverter - Sunland inverter

Generally speaking, the inverter will inevitably present some problems during operation, such as oscillation and noise, which are common problems in VFD operations. So, what causes oscillation and noise in VFDs? What is the solution to these problems? Here are the causes of VFD oscillation and noise ...

Sunland SB200 37KW inverter does not show analysis Sunland SB200 37KW inverter does not show analysis

After inspection, the circuit board of the machine is composed of a fan switching power supply board, a control board with a switching power supply and a driving board, etc., the fan power supply and the control board working power supply are independent of each other, the fan power supply output is normal, and the control board working power supply has no output due to failure. ...

The difference between inverter and inverter power supply - Senlan inverter The difference between inverter and inverter power supply - Senlan inverter

What is an inverter power supply? A variable frequency power supply converts the alternating current from the main power supply from AC→DC→AC to a pure sine wave. The output frequency and voltage can be adjusted within a specific range. Unlike the inverter governor used for the speed control of electric motors, it is also different from the general AC power supply. Aspiring AC ...

The difference between soft starter and inverter - Sunland inverter The difference between soft starter and inverter - Sunland inverter

Soft starter is actually a motor control device with motor soft start, soft stop, light load energy saving and a variety of maintenance functions. First of all, it is a three-opposite parallel thyristor and its electronic control circuit connected in series between the power supply and the controlled motor. By manipulating the conduction of three opposite parallel thyristors ...

The reason for the increase of the torque of the inverter - Senlan inverter The reason for the increase of the torque of the inverter - Senlan inverter

It is important to set the torque to improve the function. When the power frequency of the motor decreases, the speed of the motor will also decrease, and if the load torque remains unchanged, the output power will also decrease. According to the principle of conservation of energy, if the rotation of the load ...

The device inside the inverter that needs to be replaced regularly - Sunland The device inside the inverter that needs to be replaced regularly - Sunland

1. Cooling fan As a prerequisite to ensure the normal operation of the inverter, efficient and fast in-line cooling fans have become an indispensable conversion configuration of the inverter. Because of the wear of the internal bearings of the cooling fan and the reduction of the grease function in the process of application, the cooling of the fan.

A contactor is used between the inverter and the motor - Senlan inverter A contactor is used between the inverter and the motor - Senlan inverter

Whether a contactor is used between the inverter (VFD) and the motor depends on the specific situation. When the contactor is on and off when the motor is running, the operating overvoltage is easy to cause VFD damage. Therefore, whether to use the contactor, it must be based on the actual situation to make the correct ...

Inverter with no-load operation debugging steps - Sunland inverter Inverter with no-load operation debugging steps - Sunland inverter

The following four steps are very important for the commissioning of the inverter with the machine (i.e., connected to the motor) and no-load (i.e., the motor without load). (1) Set the power of the motor, the number of pole pairs, and determine the working current of the inverter. ( ...

The sequence of inverter commissioning steps - Sunland inverter The sequence of inverter commissioning steps - Sunland inverter

Investigation of the function of the inverter system Before debugging the inverter, it is necessary to carefully read the instruction manual and related information of the inverter to be debugged to understand the use environment and precautions. Especially before the inverter is energized, it is necessary to carefully investigate and check whether the inverter has obvious problems.

Effect of inrush current on inverter - Senlan Effect of inrush current on inverter - Senlan

In the process of repairing the inverter, we can find that because of the back electromotive force in the stator winding, the electromotive force in the synchronous generator state and the self-induced electromotive force in the self-loop rotor, the current impact will inevitably have a negative impact on the motor, the inverter (Variable-frequency ...

Senlan wiring knowledge Senlan wiring knowledge

1. Wiring of fire emergency lighting Generally, the flame retardant wire is used to wear the metal pipe and the thickness of the protective layer is ≥ 30mm, in the decoration project, when the emergency lighting circuit can only be applied to the ceiling, the heat-resistant or fire-resistant wire should be selected and the fire-resistant and heat-resistant matching should be considered.

Advantages of Senlan vector control system Advantages of Senlan vector control system

Dynamic "fast response" DC motors are rectified constrained and excessively high di/dt is not allowed. The asynchronous motor is only constrained by the capacity of the inverter, and the multiple of the forced current can be very high, so the speed echoes quickly, generally reaching the millisecond level, which has surpassed the DC motor in terms of speed. At low frequencies ...

The method of selecting the appropriate peripheral equipment for the inverter - Senland The method of selecting the appropriate peripheral equipment for the inverter - Senland

When we have selected a suitable Variable-frequency Drive (VFD), we also need to consider whether we need to equip other peripheral equipment according to the actual situation of the site. The peripheral equipment selected by VFD mainly includes circuit breakers, reactors, contactors, braking resistors, etc. ...

Inverter device inspection and maintenance work steps Inverter device inspection and maintenance work steps

1. Preparation process: Abort the device and admit that the motor is completely aborted. Press the stop button on the operator panel to stop the operation. Disconnect the external mains power supply (low-voltage cabinet drawer). Adequate security treatment should be carried out to ensure that it is indeed disconnected and that it does not ...

Hope Sunland inverter EMC rules Hope Sunland inverter EMC rules

When various factory equipment uses frequency conversion speed regulation, harmonic disturbances will be generated on the power supply side and motor side of the inverter (VFD), which will cause electromagnetic disturbance to the power supply network and other electrical equipment near the VFD. In addition, in order to ensure the long-term reliable operation of the VFD, the wiring of the VFD is very important. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top