Liquefied petroleum gas regulator
Fisher LPG pressure regulators are used to compensate for fluctuating tank pressures and supply constant pressure of propane gas to furnaces, burners, appliances, farm faucets, commercial companies, and plants.
natural gas
Fisher natural gas pressure control products are used in transmission and distribution stations, city gate stations and small town gas, residential, commercial, and industrial applications.
decompression
Fisher decompression regulators maintain the desired outlet pressure, providing the flow required to meet changes in downstream demand. The pressure reducing regulator maintains the pressure at the outlet pressure set by the regulator.
City Gate Station/Distribution Station
Fisher pressure regulators regulate pressure to supply air to a pressure range that can be used by commercial and residential users.
310A Series Pressure Reducer
The Model 310A Fuel Regulator is used in high-pressure applications that require a quick response, such as the supply of combustible gases for gas turbines or other high-volume applications. The Model 310A Fuel Regulator includes a Model 32A pilot assembly mounted on the main valve for decompression or full-open monitoring applications.
The 310A fuel regulator features precise control, tight shutdown, high capacity, low pressure relief requirements, and fast response.
In addition, the Model 310A fuel regulator requires very little installation space.
Features and Benefits:
High circulation
The shut-off is tight
Precise control
Minimal installation space is required
specification
Body size and end connection
1 NPT; NPS 1, 2, 3, 4 or 4 x 6 / DN 25, 50, 80 100 or 100 x 200 with CL300 RF,
CL600 RF flange ends
* Large inlet pressure
1480 psig / 102 bar
* Large outlet (housing) pressure
1480 psig / 102 bar
Outlet pressure range
10 to 750 psig / 0.69 to 51.7 bar, five ranges
Pressure method
External pressure
Temperature range
-20° to 300°F / -29° to 149°C
This article introduces the Fisher/Fisher pressure regulator 310A series products, if you are interested in the Fisher/Fisher pressure regulator, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
Fisher/Fisher DMA/AF desuperheaters in a variety of shapes
The Fisher DMA/AF is a multi-shaped, mechanically atomized, backpressure-activated superheater interstage desuperheater. Designed for applications that require control of moderate load fluctuations and high thermal cycling.
specification
Certified PED, CRN
Severe service steam conditioning
Materials SA105, F22, F91
Job...
|
|
Fisher/Fisher multi-way valves
Fisher multi-way valves and actuators divert fluid from a single fluid line to a test outlet or sampling device. A single multi-flow selector acts as a manifold that brings together eight fluid lines at once. Actuator is an electronic device designed to control and monitor the operation of multiple flow selectors.
|
|
Fisher/Fisher M Series Handwheel Turbine Actuators
The Fisher M-Series Hand Turbine Actuator is a fully enclosed, all-weather turbine actuator that provides reliable manual operation for the Fisher A11, A31A, and A41 high-performance butterfly valves.
The Fisher M Series Hand Turbine Actuator consists of a body shell, cover, turbine, ...
|
|
Fisher/Fisher TBX-T desuperheater
The Fisher TBX-T desuperheater can be used in a variety of applications to effectively reduce the temperature of superheated steam to the ideal set point. The TBX-T can be installed in steam lines with diameters DN 200 to DN 1200 (NPS 8 to 48) and can maintain steam temperatures at 6°C (10° ...
|
|
Fisher/Fisher AT-18/28 Heavy Duty A.T.-Temp Desuperheater
The Fisher Yarway AT-18/28 Heavy Duty A.T.-Temp Desuperheater was developed specifically for medium/high pressure steam applications. Its prefabricated structure can easily meet a variety of boiler specifications and material specifications. The unit can also be used as an injector for liquid injection gases, typically with high-grade alloys such as stainless steel.
...
|
|
Fisher/Fisher Model 92S Self-Operated Control Valve
The Model 92S self-actuated control valve is piston-actuated and can be used in high circulation steam applications. The base of the Model 92S control valve and pilot has an abrasive surface that has been shown to minimize base leakage. Both the 6492H and 6492L commanders are equipped with bellows to reduce guide rod friction ...
|
|
Fisher/Fisher pipe silencer
Complete Fisher pipe silencers provide superior noise reduction performance for applications where valves generate a lot of noise. Once installed, the total system pressure drop is split between the valve and the silencer. This allows the valve to operate at a lower pressure drop ratio, reducing the noise generated during the flow through the control valve.
|
|
Fisher/Fisher A11 High Performance Butterfly Valve Stem Dynamic Loading
Introduction: The Fisher/Fisher A11 High Performance Butterfly Valve is a reliable, high-performance butterfly valve for throttling and switching applications. Available in a pair of clamp or single flange designs to maintain tight shut-off over long periods of time, the valve is specific for a wide range of pressure and temperature conditions, including cryogenic applications.
|
|
Fisher/Fisher V260 Control Valve
The Fisher V260 is a full-bore control valve with a bottom-up design that maximizes pressure, flow, and process control. Integral borehole silencers are used to control noise and vibration generated by high-pressure drop liquids and gases. The spline shaft is connected with the actuator, which reduces the movement loss. ...
|
|
Fisher/Fisher easy-e ET control valves
The Fisher easy-e ET is the ideal solution for all high process temperature general applications, with a balanced plug design and cage guided trims. Available with straight-through or angled bodies, these valves provide up to Class V or Level VI shut-off
specification
Certified to SIL, fugitive emissions, N...
|
|
Fisher/Fisher ATST steam atomizing desuperheater
The Fisher ATST desuperheater is a state-of-the-art solution for desuperheating applications where atomization performance and amplitude of variation are critical. ATST nozzles atomize water through steam atomization to form tiny water droplets that evaporate rapidly over a wide range of vapor flows and conditions.
specification
Certificates: PED, CRN
...
|
|
Fisher/Fisher FB Welded Angle Valve PEEK Drop Resistant
Introduction: Fisher/Fisher FB welded angle valves control compressible fluids and can be used in special applications that require maximum noise reduction and high flow capacity. Typical applications include main steam pressure reducing valves and compressor bypass valves. FB valves are also commonly used in petrochemical and natural gas processing plants for acidic ...
|
|
Fisher/Fisher CAV4 valves
The Fisher CAV4 valve is designed for clean, cavitation applications with a pressure drop of more than 207 bar (3000 psi). The Cavitrol™ IV trim in the valve is designed to extend the flow area. Each trim stage has a sequentially increasing flow zone. This guarantees a very ...
|
|
Fisher/Fisher 3610J Pneumatic, Single-Acting Positioner
The Fisher 3610J pneumatic positioner can be used with a single-acting rotary actuator to precisely locate control valves used in throttling applications. These positioners are rugged and provide valve positioning proportional to the pneumatic input signal or DC current input signal and as a whole ...
|
|
Fisher/Fisher V280 Full Bore Ball Control Valve
The Fisher V280 is a three-piece, trunnion-style, full-bore control valve that handles all CL900 pressure drops. Optimized pressure, flow, and process control. An optional borehole silencer controls noise and vibration from high-pressure drop liquids and gases. The spline shaft is connected with the actuator, which reduces the ...
|
|
Fisher/Fisher 657 and 667 Spring Diaphragm Pneumatic Actuators
Versatility of application - 5 models and 11 sizes of actuators are available for a wide range of applications. A wide range of spring rates, stroke limiters, and manual operators are available for use in virtually any control valve application.
There is an excellent linear relationship between the loading pressure and the stroke.
|
|
Fisher/Fisher Model 630 Regulator
The Fisher/Fisher Model 630 regulator is designed to provide fast and economical pressure control for a wide range of applications and is suitable for a wide range of gaseous media
Specifications:
Process Gases/Specialty Gases
Fisher pressure control products are suitable for chemical industry processes such as analytical ...
|
|
Fisher/Fisher D2T FloPro Control Valve 2250 psig pressure drop force
Introduction: The Fisher/Fisher D2T valve is best suited for use as a dump valve for gas separators and scrubbers. It is also suitable for other high-pressure applications in natural gas production, compression and processing.
Features:
Optional 1 NPT end connection.
Have a C ...
|
|
Fisher/Fisher R222 Series Secondary Regulators
The R222 series regulators are certified by Underwriters Laboratories (United States Safety Testing Laboratories, Inc.) for use in LPG two-stage pressure regulating systems. The unit reduces the outlet pressure of the primary regulator (typically from 10 psig / 0.69 bar) to 11-in ...
|
|
Fisher/Fisher 377 Pressure Sensitive Guard Valve
The Fisher 377 guard valve assists in maintaining routine process operations that require a specific valve or actuator. When the compressed air pressure drops below the trigger point, the guard valve prevents the actuator from rising, locking in the previous position, or not descending. When the compressed air pressure rises above the trigger point, 3 ...
|
|