1. Effect of temperature
Rosemount differential pressure transmitters will vary greatly in process temperature, ambient temperature, and will certainly differ from the reference conditions when the transmitter is tested, which also means that the functionality will be different from the reference accuracy presented. The effect of temperature on differential pressure transmitters is small when approaching the maximum range (i.e., small range ratio), but the effect is large when approaching the minimum range (i.e., large volume ratio), sometimes even beyond our imagination. According to some product manuals, if the maximum range ratio is 100, the effect can be close to 10%.
2. Effect of turndown ratio
The turndown ratio of a Rosemount differential pressure transmitter is the ratio of the maximum value to the minimum value that can be measured by the transmitter if the accuracy requirements are satisfied. In general, the larger the measuring ratio, the lower the measurement accuracy, the larger the measuring capacity ratio of the pressure transmitter, there are many advantages, so that after the adjustment of an instrument, it can be used in a number of different occasions. However, in practice, if the range ratio is too high, it will bring many problems of measurement stability.
3. Effect of static pressure
Similar to the effects of temperature and range, hydrostatic pressure also has a substantial impact on the accuracy of the transmitter's zero point and range. Such as capacitive differential pressure transmitter, this transmitter in the production process system operation process, will simply be affected by static pressure, when the static pressure of the operating conditions exceeds a certain value, the error of the static pressure influence will exceed the accuracy of the transmitter itself, when the channel accuracy accounting of the measurement channel, if the static pressure influence error, it may not be able to meet the channel accuracy requirements, so the capacitive differential pressure transmitter must be corrected when calibrating
|
More on that
|
Features of Rosemount pressure transmitters:
The main features of Rosemount pressure transmitters are as follows:
1. It has the function of converting high and low pressure side:
The conversion function of the high and low voltage side of this sensor is mainly through the adjustment of the internal parameters of the handheld communicator, and the useful data on the high and low voltage side is realized.
|
|
The Rosemount 3051 transmitter resets the range
There are three ways to reset the range of the 3051 transmitter:
1. Use only the communicator to reset the range
HART communicator shortcut keys 4 or 5. The simplest and most common way to reset the range using only the communicator is to change the values that mimic points 4 and 20 mA independently, without the need for pressure inputs.
|
|
Rosemount transmitters are affected by the angle of inclination of the installation
The actual working performance of the Rosemount transmitter will be affected by the angle of inclination, ambient temperature, static pressure and fluid temperature of the device.
|
|
Types of Rosemount transmitters
The intelligent Rosemount transmitter is also equipped with a hand-held terminal (external data setter or grouper) for setting the transmitter parameters, such as setting the type of transmitter, range adjustment, zero point adjustment, input signal selection, output signal selection, engineering unit selection and damping time constant.
|
|
Features and performance of Rosemount pressure sensors
Features and performance of Rosemount pressure sensors
1. Diffusion silicon pressure sensor
The working principle of the diffusion silicon pressure sensor is that the pressure of the measured medium acts directly on the diaphragm of the sensor (stainless steel or ceramic), so that the diaphragm produces a micro-displacement proportional to the pressure of the medium, ...
|
|
Features of the Rosemount 8732E Electromagnetic Flowmeter:
Features of the Rosemount 8732E Electromagnetic Flowmeter
1. The measurement is not affected by the changes in fluid density, viscosity, temperature, pressure and conductivity.
2. There are no blocking moving parts in the measuring pipe, no pressure loss, and the requirements for the straight pipe section are low. It has unique adaptability to slurry measurement.
...
|
|
Factors to consider for Rosemount 5300 Series Radar Level Gauge Interface Measurements
For applications where the waveguide is completely submerged in liquids, the Rosemount 5301 measurement interface can be used, but the following guidelines should be followed
1. The dielectric constant of the above product must be known and cannot be changed. The Radar Master software has built-in dielectric constant calculations ...
|
|
Pipe diameter requirements for the installation of the Rosemount 8800D vortex flowmeter
1. The upstream and downstream pipe diameter of the flowmeter on the installation point must be installed in accordance with the standard flowmeter caliber, otherwise the measurement accuracy will be affected.
2. If there is a tapering pipe in the upstream of the flowmeter installation point, there should be a straight pipe section of equal diameter of not less than 15D (D is the diameter of the pipe) in the upstream of the flowmeter, and there should be ...
|
|
Key Features of the Rosemount 248 Temperature Transmitter:
Top mount and rail mount applications provide 2-year stability.
The integrated LCD meter provides easy indication of the process and diagnostic indications.
Available as a ready-to-install solution, including a wide range of sensors, thermowells, and housings.
Polished stainless steel housing can be applied to ...
|
|
Features that Rosemount Instrument Thermowells have
Rosemount Instrument Heat Jacket has the following features:
1. Similar tags – when presenting some similar applications that only need to be changed slightly, it should be possible to imitate the application value of a specific tag, and then there is no need to re-enter the repetitive information, only change the variables that need to be changed in the new use.
|
|
Rosemount temperature transmitter performance improvements
The fundamental function of the Rosemount 644 temperature transmitter is to make serious improvements based on extensive user feedback and application sensitivity requirements in various industries.
1. Power terminal placement: Now the power supply and communication terminal are placed at the bottom right of the equipment, and the LCD can be carried out without removing the LCD.
|
|
Features of the Rosemount Transmitter 3051S Series High Precision Transmitters:
Features of the Rosemount Transmitter 3051S Series High Precision Transmitters:
Advanced diagnosis
Advanced diagnosis provides ongoing process monitoring to ensure the integrity and security of the process environment. The Statistical Process Monitoring (SPM) skill alerts you to deal with issues and anomalies. This comprehensive ...
|
|
How to choose a Rosemount transmitter for standard accuracy
Not every Rosemount product is the same, for example, the 3051 pressure transmitter and the 3051S high-precision pressure transmitter are not in the same range. But there is also a big relationship between the two. For example, the 3051CD transmitter is now used in ...
|
|
How to choose the Rosemount 3051DP differential pressure transmitter
1.3051D transmitter is a coplanar pressure transmitter, which can measure the pressure or the side differential pressure, and there are two options P is the differential pressure measurement and G is the gauge pressure.
2. To understand the range used in the field, select the corresponding code according to the range, a total of 5 options: the lowest - 6.216KPA and the maximum 13789.54KPA.
...
|
|
The Rosemount Twisted Square thermowell avoids wake shedding
When a problem arises in the design of Rosemount thermowells, it is necessary to analyze the cause of its failure, and then go further and propose solutions. In some less complicated cases, it may be necessary to make a small change, such as adding one millimeter without changing the predetermined measurement orientation ...
|
|
Eight ways to maintain your Rosemount 3051 pressure transmitter
1. When measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer tube (coil), and the working temperature of the Rosemount transmitter should not exceed the limit.
2. When wiring, pass the cable through the waterproof joint or winding pipe and tighten the sealing nut to prevent rain from leaking through the cable.
|
|
Three types of Rosemount 3051 transmitters
There are many types of Rosemount 3051 transmitters, and there are many types, today we will tell you about the most basic 3 types of transmitters of Rosemount 3051 transmitters, absolute pressure, gauge pressure, and differential pressure.
3051CA Absolute Pressure Transmitter Rosemount Reference Pressure When the Pressure is Vacuum, the ...
|
|
Fault Judgment in Rosemount Differential Pressure Transmitter Applications
Fault judgment and analysis in the application
In the process of measuring the transmitter, there are often some problems, and the timely analysis and treatment of faults are crucial for the ongoing production According to the experience of daily maintenance, some of the analysis methods and analysis methods are summarized and summarized.
|
|
Rosemount Pressure Transmitter Measurement Principle
The Rosemount pressure transmitter measurement principle progresses as follows:
1. The pressure transmitter transmits the pressure on the high and low pressure sides to the movable (sensing) diaphragm in the center of the sensor through silicone oil.
2. The movable diaphragm undergoes a slight displacement under the effect of differential pressure, so that the movable (sensing) membrane ...
|
|
How to solve the problem that the Rosemount transmitter cannot be powered on
Analysis and countermeasures when the Rosemount transmitter cannot be powered on.
1. There is something wrong with the leakage circuit breaker itself
When the jump bar indicator and power indicator are not on, it is necessary to check whether the fuse is blown; Whether transformers, voltage regulator manifolds, and power switches ...
|
|