Three types of Rosemount 3051 transmitters

Create Date: 2024-8-30 12:03:23|Source: Rosemount/Rosemount

There are many types of Rosemount 3051 transmitters, and there are many types, today we will tell you about the most basic 3 types of transmitters of Rosemount 3051 transmitters, absolute pressure, gauge pressure, and differential pressure.
Three types of Rosemount 3051 transmitters

When the 3051CA absolute pressure transmitter Rosemount reference pressure is vacuum, the measured pressure value is the absolute pressure, which is usually referred to as absolute pressure.

When the reference pressure of the 3051CG gauge pressure transmitter is the local atmospheric pressure, the measured pressure value is the gauge pressure. When the gauge pressure is positive, it is referred to as pressure, and when the gauge pressure is negative, it is called negative pressure or vacuum. As far as the negative pressure of the Rosemount series transmitters is concerned, the higher the positive value, the lower the positive pressure, and the greater the vacuum.

When the 3051CD differential pressure transmitter is operating, the barrier diaphragm and the filling solution on the high and low pressure sides transmit the process pressure to the filling solution, which then transmits the pressure to the sensing diaphragm in the center of the sensor. When the pressure to be measured is felt at both ends of the transmitter, the difference between the pressures at the two ends is called differential pressure.

These are the 3 most basic types of Rosemount 3051 transmitters.
More on that
Rosemount X-Well Wins Best Product Award in Sensor Category Rosemount X-Well Wins Best Product Award in Sensor Category

Shanghai, China (November 3, 2016) – Emerson's Rosemount X-Well Technology temperature measurement components won the Best of the Best Product Award in the Sensors category at the highly anticipated CONTROL ENGINEERING China 2016 annual competition. ...

Rosemount 3051S direct-attach pressure transmitter Rosemount 3051S direct-attach pressure transmitter

The Rosemount 3051S direct-attach pressure transmitter is a professional-class solution for optimized functionality. This scalable SuperModule™ platform reduces process variation and reduces protection, making it particularly useful for gauge and absolute pressure measurement in Rosemont transmitters. Should...

That's how Rosemount transmitters should be selected That's how Rosemount transmitters should be selected

Rosemount transmitter selection requires a good transmitter before use, so its selection is very important 1. According to the pressure interface mode Generally, threaded connection is the standard interface method. 2. According to the required accuracy level Measurement error of the transmitter ...

Problems to be noted when calibrating Rosemount transmitters Problems to be noted when calibrating Rosemount transmitters

1. After adjusting the zero point, use the standard pressure source to apply pressure slowly, and increase the pressure to the maximum scale, and the output value is about 20mA. 2. The verification regulations require that the two high and low pressure chambers of H and L are connected to the outside world, and observe that the zero position is not in the direction of 4mA.

External factors influencing the failure of the Rosemount 3051 transmitter External factors influencing the failure of the Rosemount 3051 transmitter

1. The impulse tube is faulty There are two simplest problems with the pressure duct of the Rosemount 3051 transmitter, which is blockage and leakage of the pressure duct. Once this problem is presented, the most obvious manifestation is that the leakage surface index of the impulse pipe will be abnormal.

How to choose the Rosemount 3051DP differential pressure transmitter How to choose the Rosemount 3051DP differential pressure transmitter

1.3051D transmitter is a coplanar pressure transmitter, which can measure the pressure or the side differential pressure, and there are two options P is the differential pressure measurement and G is the gauge pressure. 2. To understand the range used in the field, select the corresponding code according to the range, a total of 5 options: the lowest - 6.216KPA and the maximum 13789.54KPA. ...

How Rosemount Electromagnetic Flowmeters Troubleshoot Air Ducts How Rosemount Electromagnetic Flowmeters Troubleshoot Air Ducts

Rosemount Electromagnetic Flowmeter Eliminates Empty Pipe ProblemRosemount Electromagnetic Flowmeter Eliminates Empty Pipe Problem If the ATC detection is unexpected, the following measures can be adopted: 1. Make sure the sensor is overflowing. 2. Ensure that the measuring electrode has not been installed on the top of the pipe of the sensor. ...

How to solve the problem that the Rosemount transmitter cannot be powered on How to solve the problem that the Rosemount transmitter cannot be powered on

Analysis and countermeasures when the Rosemount transmitter cannot be powered on. 1. There is something wrong with the leakage circuit breaker itself When the jump bar indicator and power indicator are not on, it is necessary to check whether the fuse is blown; Whether transformers, voltage regulator manifolds, and power switches ...

How the Rosemount 3051TG pressure transmitter works How the Rosemount 3051TG pressure transmitter works

The Rosemount 3051TG pressure transmitter is one of the most commonly used products in the Rosemount 3051 pressure transmitter that has been tested in the power industry for 40 years. Planning with high reliability, transient stability, and easy protection. Rosemount pressure transmitters are designed from planning to installation, from protection to operation.

Key Features of the Rosemount 248 Temperature Transmitter: Key Features of the Rosemount 248 Temperature Transmitter:

Top mount and rail mount applications provide 2-year stability. The integrated LCD meter provides easy indication of the process and diagnostic indications. Available as a ready-to-install solution, including a wide range of sensors, thermowells, and housings. Polished stainless steel housing can be applied to ...

Summary of problems in the use of the Rosemount 3051 transmitter Summary of problems in the use of the Rosemount 3051 transmitter

1. What kind of output signal does the Rosemount transmitter need to obtain: mV, V, mA and frequency output digital output, and the choice of what kind of output depends on a variety of factors, including the separation between the Rosemount transmitter and the system controller or display, whether there is "noise" or other electronic interference signals.

What factors affect the performance of the Rosemount 3051 differential pressure transmitter? What factors affect the performance of the Rosemount 3051 differential pressure transmitter?

1. Effect of temperature Rosemount differential pressure transmitters will vary greatly in process temperature, ambient temperature, and will certainly differ from the reference conditions when the transmitter is tested, which also means that the functionality will be different from the reference accuracy presented. Temperature on differential pressure transmitters ...

How to choose a Rosemount transmitter for standard accuracy How to choose a Rosemount transmitter for standard accuracy

Not every Rosemount product is the same, for example, the 3051 pressure transmitter and the 3051S high-precision pressure transmitter are not in the same range. But there is also a big relationship between the two. For example, the 3051CD transmitter is now used in ...

What to do if the Rosemount pressure transmitter measurement is inaccurate What to do if the Rosemount pressure transmitter measurement is inaccurate

Common Rosemount pressure transmitter measurement incorrect situations: 1. The input impedance of the Rosemount transmitter load should be in line with RL≤ (transmitter supply voltage -12V)/(0.02A)Ω if necessary, if it does not match, corresponding measures can be adopted according to its differences: such as increasing the power supply ...

Types of Rosemount transmitters Types of Rosemount transmitters

The intelligent Rosemount transmitter is also equipped with a hand-held terminal (external data setter or grouper) for setting the transmitter parameters, such as setting the type of transmitter, range adjustment, zero point adjustment, input signal selection, output signal selection, engineering unit selection and damping time constant.

How to troubleshoot the Rosemount 3051 differential pressure transmitter if it encounters problems How to troubleshoot the Rosemount 3051 differential pressure transmitter if it encounters problems

1. Line failure When the computer in the Rosemount transmitter monitoring system shows abnormal values, it is necessary to immediately check the line status of the junction box of the differential pressure transmitter to see if there is a short circuit, etc., and the way to check is to measure the resistance. ...

The Rosemount 3051 transmitter is prone to some failures The Rosemount 3051 transmitter is prone to some failures

1. The pressure of the 3051 transmitter does not go up to the output of the transmitter, the output of the pressurized transmitter does not change, and the output of the pressure transmitter changes suddenly, and the zero position of the pressure relief transmitter cannot be returned. In this case, you should see if the pressure interface is leaking or blocked, and after looking at the wiring method and power supply, ...

Rosemount transmitters feature two-way communication Rosemount transmitters feature two-way communication

The intelligent Rosemount transmitter is composed of a sensor and a microprocessor (microcomputer), which makes full use of the computing and storage capabilities of the microprocessor to process the data of the sensor, including the conditioning of the measurement signal (such as filtering, amplification, A/D conversion, etc.), data display, etc.

An indispensable accessory for Rosemount transmitters An indispensable accessory for Rosemount transmitters

Before selecting a Rosemount transmitter, it is necessary to consider whether it is a threaded device or a flanged device, and the flanged device is divided into a single flange device and a double flange device. In order to let you better choose the flange, we have summarized some knowledge about the flange type: Threading ...

Pipe diameter requirements for the installation of the Rosemount 8800D vortex flowmeter Pipe diameter requirements for the installation of the Rosemount 8800D vortex flowmeter

1. The upstream and downstream pipe diameter of the flowmeter on the installation point must be installed in accordance with the standard flowmeter caliber, otherwise the measurement accuracy will be affected. 2. If there is a tapering pipe in the upstream of the flowmeter installation point, there should be a straight pipe section of equal diameter of not less than 15D (D is the diameter of the pipe) in the upstream of the flowmeter, and there should be ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top