The meaning of the Rosemount transmitter fault code indication

Create Date: 2024-8-30 12:03:23|Source: Rosemount/Rosemount

Press Limit: The process variable read out by the transmitter is not within the transmitter range, which means that the range of the set volume exceeds the range of the transmitter cassette, and the solution is to replace the transmitter cassette.
The meaning of the Rosemount transmitter fault code indication
  Temp Limit: The second variable temperature read out by the transmitter is not within the transmitter's range and exceeds the transmitter's own maximum or minimum temperature.

Curr Fixed: The transmitter is in a multi-station module. The analog output cannot be monitored for changes in pressure.

Curr Saturd: The pressure read out by the module is not within the specified range and the analog output is forced to change to full level.

Span Fail: The range value set by the local range adjustment button exceeds the maximum range of a specific range, or the pressure experienced by the transmitter exceeds the sensor's limit.

LOCAL DSBLD: This message is displayed when the range is reset with the integrated zero and range buttons, indicating that the transmitter's native zero and range adjustment functions are disabled. The local tuning function may be disabled by the transmitter safety jumper on the transmitter board, or by the Model 275 communication device command. Information about safety jumpers and software determination.

Loop Test: The loop test is in progress. During loop testing or 4-20 mA fine-tuning, the analog output is set to a fixed value. The meter display will alternate between the selected current value in milliamps and the "LOOP TEST".
More on that
Problems to be noted when calibrating Rosemount transmitters Problems to be noted when calibrating Rosemount transmitters

1. After adjusting the zero point, use the standard pressure source to apply pressure slowly, and increase the pressure to the maximum scale, and the output value is about 20mA. 2. The verification regulations require that the two high and low pressure chambers of H and L are connected to the outside world, and observe that the zero position is not in the direction of 4mA.

How to maintain and clean the Rosemount 3051DP differential pressure transmitter How to maintain and clean the Rosemount 3051DP differential pressure transmitter

After a period of use, the Rosemount 3051DP differential pressure transmitter needs to be cleaned regularly to maintain the accuracy of the differential pressure transmitter and achieve the desired function. Generally, the differential pressure transmitter should be cleaned in the following order: 1. Close the high-voltage side ...

In 2018, the Rosemount electromagnetic flowmeter received new certification In 2018, the Rosemount electromagnetic flowmeter received new certification

In 2018, NAMUR passed the technical certification, and the Rosmont 8700 series electromagnetic flowmeters were finally certified by NAMUR, allowing automation products to better enter the European chemical market The Germany Committee for Measurement and Control Standards "designates NAMUR as a standard, which is based on industrial ...

What are the features of the Rosemount 644 temperature transmitter? What are the features of the Rosemount 644 temperature transmitter?

1. It can greatly reduce the cost of wire and labor. 2. The advanced diagnosis function can reduce the number of on-site repairs. 3. Order a complete temperature transmitter and temperature sensing assembly to simplify setup, specifications, and ordering, and then reduce costs. 4. Adopt HART communication protocol. ...

Installation of Rosemount transmitter attachments Installation of Rosemount transmitter attachments

The Rosemount transmitter is an important accessory in the use of time and time and time components, which will also affect the accuracy of the transmitter measurement results. Therefore, in order to prevent the occurrence of measurement errors, we need to pay attention to the following points in the equipment process of additional equipment.   1. Rosemont ...

How to choose the Rosemount 3051DP differential pressure transmitter How to choose the Rosemount 3051DP differential pressure transmitter

1.3051D transmitter is a coplanar pressure transmitter, which can measure the pressure or the side differential pressure, and there are two options P is the differential pressure measurement and G is the gauge pressure. 2. To understand the range used in the field, select the corresponding code according to the range, a total of 5 options: the lowest - 6.216KPA and the maximum 13789.54KPA. ...

Eight ways to maintain your Rosemount 3051 pressure transmitter Eight ways to maintain your Rosemount 3051 pressure transmitter

1. When measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer tube (coil), and the working temperature of the Rosemount transmitter should not exceed the limit. 2. When wiring, pass the cable through the waterproof joint or winding pipe and tighten the sealing nut to prevent rain from leaking through the cable.

That's how Rosemount transmitters should be selected That's how Rosemount transmitters should be selected

Rosemount transmitter selection requires a good transmitter before use, so its selection is very important 1. According to the pressure interface mode Generally, threaded connection is the standard interface method. 2. According to the required accuracy level Measurement error of the transmitter ...

The Rosemount 3051 transmitter meter shows what the cause of the FAIL fault is The Rosemount 3051 transmitter meter shows what the cause of the FAIL fault is

1. Look at whether the diaphragm is damaged, if not, after removing it, press it with chopsticks after imitating the power on in the room to see if there is a pressure display, if there is a display change, you can only disassemble another one, see if the transmitter module is broken, because the transmitter modules are integrated ...

Rosemount temperature transmitter performance improvements Rosemount temperature transmitter performance improvements

The fundamental function of the Rosemount 644 temperature transmitter is to make serious improvements based on extensive user feedback and application sensitivity requirements in various industries. 1. Power terminal placement: Now the power supply and communication terminal are placed at the bottom right of the equipment, and the LCD can be carried out without removing the LCD.

Features of the Rosemount 8732E Electromagnetic Flowmeter: Features of the Rosemount 8732E Electromagnetic Flowmeter:

1. The measurement is not affected by the change of fluid density, viscosity, temperature, pressure and conductivity. 2. There are no obstruction moving parts in the measuring pipe, no pressure loss, and the requirements for the straight pipe section are low. There is a common adaptability to slurry measurement. 3. Reasonable selection of sensor lining and electrode materials, ...

Rosemount 3051S direct-attach pressure transmitter Rosemount 3051S direct-attach pressure transmitter

The Rosemount 3051S direct-attach pressure transmitter is a professional-class solution for optimized functionality. This scalable SuperModule™ platform reduces process variation and reduces protection, making it particularly useful for gauge and absolute pressure measurement in Rosemont transmitters. Should...

Rosemount 3144P Temperature Transmitter Installation Steps Rosemount 3144P Temperature Transmitter Installation Steps

Typical on-site installation 1. Install the thermowell to the wall of the process vessel. 2. Install and tighten the thermowell. 3. Perform a leak check. 4. Connect all necessary couplings, couplings and extension fittings. Seal the dispensing with a certified thread sealant ...

What is the difference between a Siemens transmitter and a Rosemount transmitter What is the difference between a Siemens transmitter and a Rosemount transmitter

Differences between Siemens transmitters and Rosemount transmitters: Siemens' transmitters are piezoresistive pressure transmitters, while Rosemount's transmitters are capacitive pressure transmitters. The transmitter converts the output signal of the sensor into other signals that can be recognized by the controller.

The Rosemount 3051 transmitter has its own advantages The Rosemount 3051 transmitter has its own advantages

1. The five-year stable soil is 0.125%, which can greatly reduce the cost of verification and protection. 2. Faster dynamic response, which can reduce the variability of the process. 3. The co-plane planning can realize a comprehensive measurement scheme. 4. Compact and lightweight coplanar planning with the best function ...

Factors to consider when installing a Rosemount 644 temperature transmitter Factors to consider when installing a Rosemount 644 temperature transmitter

Rosemount 644 temperature transmitter must be considered when installing the factors, only we solve these unfavorable factors, in the installation of the Rosemount temperature transmitter will not encounter some unnecessary things routine Electrical temperatures such as RTDs and thermocouples ...

Rosemount differential pressure transmitter selection considerations Rosemount differential pressure transmitter selection considerations

The following points should be considered in the selection of differential pressure transmitters: 1. Measure the scale, the accuracy of the demand and the measurement function; 2. Measure the environment of the outer surface, such as the industrial environment of petrochemical industry, the existence of flammable, toxic and explosive risk atmosphere, and the high ambient temperature; 3 tested ...

The Rosemount Twisted Square thermowell avoids wake shedding The Rosemount Twisted Square thermowell avoids wake shedding

When a problem arises in the design of Rosemount thermowells, it is necessary to analyze the cause of its failure, and then go further and propose solutions. In some less complicated cases, it may be necessary to make a small change, such as adding one millimeter without changing the predetermined measurement orientation ...

How to care for your Rosemount pressure transmitter after use How to care for your Rosemount pressure transmitter after use

Eight ways to use Rosemount pressure transmitters: 1. When measuring steam or other high-temperature media, it is necessary to connect a condenser such as a buffer tube (coil), and the working temperature of the Rosemount transmitter should not exceed the limit. 2. When wiring, pass the cable through the waterproof joint or wrap it around.

Rosemount transmitter pressure gauges are widely used Rosemount transmitter pressure gauges are widely used

Rosemount transmitters are used in industrial process control and technical measurement processes, because the elastic and sensitive elements of mechanical pressure gauges have high mechanical strength and easy production, so that mechanical pressure gauges are more and more widely used.   Rosemont ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top