What are the main application areas of Omron relays?
In terms of application fields, Omron relays can be used in the following fields:
1) Home appliance market
Representative models: G5Q, G2RL, G5NB, G4A and other power relays
2) Medical market
Representative models: G6J-Y, G6S, G6K and other signal relays
...
|
|
Omron's digital predictive maintenance prototype enables predictive maintenance without relying on skilled workers
With the development of society, manufacturing sites are facing new issues, such as the lack of skilled maintenance personnel, the aging of existing equipment, and the increase in equipment accident losses due to high value-added products. To this end, Omron relies on mature automation technology to electronically transform maintenance skills ...
|
|
The Omron CK3M/CK5M series has four major features to solve the problem of motion control
How can ultra-precision operations be realized in semiconductor and FPD manufacturing/inspection equipment, such as exposure machines, coating machines, dispensing machines, and wafer inspection equipment?
How to control special mechanical mechanisms, such as those with robotic mechanisms, in the manufacture of smart devices?
Machining Machine/Stamping Machine ...
|
|
The application of Omron temperature uniformity technology in SEMI homogenizing developer
Process introduction
The gluing developer is a very important equipment for the lithography process section of chip making, which is used to realize the ultra-thin film of photoresist. It is divided into two steps: 1. Gluing process: the photoresist is dropped onto the surface of the wafer through the glue head, and the vacuum suction cup sucks the wafer and rotates at high speed for homogenization.
|
|
The reason why the ER light is always on after the Omron PLC is powered on
1. Fault phenomenon: The ERR light is always on when the PLC is powered on, and the PLC is not working.
2. Cause of failure:
(1) Poor use environment leads to oxidation and corrosion of internal MPU, memory, and even substrates.
(2) Due to electromagnetic interference, noise interference, static electricity, etc., the internal MPU ...
|
|
Address allocation of Omron PLC - CPU unit address allocation
1. CPU unit address allocation
Type X and XA CPUs
The X and XA CPU units come with 40 I/O, of which 24 are inputs and 16 are outputs, and the input part of the CIO area occupies 0 - 1 channel, with a total of 24 input bits:
12 of these bits are 0 bits of channel 00—— ...
|
|
Omron relays – the role of intermediate relays
1. Replace small contactors
The contacts of the intermediate relay have a certain load capacity, and when the load capacity is relatively small, it can be used to replace the use of small contactors, such as electric roller shutters and the control of some small household appliances. Such an advantage is that it can not only serve the purpose of control, but ...
|
|
Analysis of common failures of Omron PLC
1. External equipment failure. Such faults come from external devices such as various sensors, switches, actuators, and loads. The failure of this part of the equipment will directly affect the control function of the system. This type of failure is usually caused by the quality and longevity of the equipment itself.
2. System failure ...
|
|
【Omron industry case】The application of robots in the assembly line of automobile high-pressure oil pump
Equipment Overview
The high-pressure oil pump (abbreviation: HDP) is the main power source to drive the fuel pressure of the automobile engine.
The "high-pressure oil pump robot automatic assembly line" mainly realizes the intelligent supply of each component on the high-pressure oil pump and the automatic assembly of each component by the robot.
Work...
|
|
The reason and solution for the ERC light of the DA08C output module of Omron plc
The ERC light of the DA08C output module indicates that the module is faulty, which may be caused by the incorrect electrical structure of the output terminal or the power supply overload.
Solution:
1. Check the electrical structure of the output terminal to ensure that the terminal coil is in correct contact;
2. Check the inside of the module ...
|
|
Common faults and maintenance methods of Omron micro switches
One
Omron micro switches in daily use, so we often encounter the phenomenon that the cover of the switch falls off, how does the cover of the switch fall off? The main reason for this is also to be sure that the cover of the switch falls off due to the excessive operation of the key switch.
|
|
Analysis of common Omron fault codes
1. C200H series PLC fault codes:
- E0001: Undefined program error
- E0002: Undefined instruction error
- E0003: Missing Program Error
- E0004: Data error
- E0005: Pointer error
- E0006: ...
|
|
Omron PLC - PLC common fault maintenance and handling methods
1. The CPU is abnormal
When an abnormal CPU alarm, check all devices connected to the internal bus of the CPU unit. The specific method is to replace the units that may cause failures in turn, find out the faulty units, and deal with them accordingly.
2. The memory is abnormal
When the memory is abnormal ...
|
|
Common fault problems of Omron relays
1. Do not exceed the rated voltage of load current during the use of OMRON relay, because when the applied rated voltage is too large, it may cause a local short circuit between the cores of the OMRON relay coil and poor operation of the AC operation relay. And it may also cause a succession ...
|
|
The working principle and purpose of Omron relays
How it works
Add a certain voltage at both ends of the coil, a certain current will flow through the coil, thus producing an electromagnetic effect, and the armature will overcome the tensile force of the return spring under the action of electromagnetic force attraction and attract to the core, thereby driving the dynamic contact and static contact (normally open contact) of the armature ...
|
|
The division of the storage area of Omron PLC
1. I/O relay area: there are 30 channels in total, and the address is 000-029. An idle relay or channel can be used as an intermediate relay. The rack slot number is from 007CH to 001CH from the left of the CPU unit.
The I/O address number is represented by 5 digits: 1, single digit, ten digits indicate the relay ...
|
|
Omron attended the 2022 P&G Electrical Automation Symposium
Recently, the 2022 P&G Electrical Automation Seminar held by Procter & Gamble (China) Co., Ltd. (hereinafter referred to as "P&G") was held in Guangzhou. Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") was invited to attend the meeting and worked with the engineering, manufacturing, R&D and other departments of P&G factories on behalf of the ...
|
|
FAQs on Omron PLC
1.How to install the USB driver of CP1H?
The computer is connected to CP1H (powered on) through a USB cable, and the PC will automatically prompt to find the new hardware and prompt to install the driver.
2.The built-in USB port of CP1H can be used ...
|
|
What are some common failures of Omron?
Common troubleshooting methods for Omron are as follows:
(1) Failure of peripheral circuit components
This kind of failure is more common in PLC maintenance, and it is generally a frequent occurrence in failures after a certain period of work. In the PLC control loop, if there is a component damage fault, the PLC control system ...
|
|
What are the common faults of Omron relays?
Fault 1:
Do not exceed the rated voltage of the load current during the use of the OMRON relay, because when the applied rated voltage is too large, it may cause a local short circuit between the cores of the OMRON relay coil and poor operation of the AC operation relay. And there are ...
|